• 제목/요약/키워드: load modelling

검색결과 395건 처리시간 0.028초

자동차의 차체강도 해석 (A study of vehicle structure analysis)

  • 이종원;조영호;박관흠
    • 오토저널
    • /
    • 제5권1호
    • /
    • pp.54-62
    • /
    • 1983
  • This paper presents structural analyses performed on the white body of vehicle using the most competitive analyzer, Finite Element Method, and attempts to obtain design criteria of body. By applying the substructure and restart technique to structural model, computation time is reduced. The synthetic processing from modelling to graphic visualization is accomplished by several subprograms, viz., various pre-post processors. On the basis of home-made vehicle modeling, typical cases of accident and service load is analyzed and discussed. The results obtained will guide the designer to design the structure optimally.

  • PDF

모터부하를 고려한 ON-LINE 안정도 해석 (Power System Stability Analysis Considering Motor Loads)

  • 박지호;백영식;이희춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.316-318
    • /
    • 2000
  • In this paper. we have simulated the transient stability of power system with motor loads. In study of power system stability, modelling of motors is required for the system with large concentrations of motors. Therefore the dynamics attributable to motors are usually the most significant aspects of dynamics characteristics of system loads. A synchronous motor is modelled as a dynamic load. We investigate the effect of synchronous motors of Kwang Yang network with three phase fault.

  • PDF

동적인 부하를 고려한 전력계통의 안정도 해석 (Power System Stability Analysis Considering Dynamic Loads)

  • 박지호;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.187-189
    • /
    • 2001
  • In this paper, we have simulated the transient stability of power system with dynamic loads. Dynamic load characteristics have an important influence on power system stability. In study of power system stability, motors form a major portion of the system loads. Induction motors and synchronous motors in particular form the workhorse of the electric power industry. Therefore modelling of motors is important in system stability. We investigate the effect of motors loads of Kwang Yang network with three phase fault.

  • PDF

A Note on Relay Feedback Identification Under Static Load Disturbances

  • Kaya, Ibrahim
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.395-400
    • /
    • 2015
  • Obtaining the parameters for PID controllers based on limit cycle information for the process in a relay controlled feedback loop has become an accepted practical procedure. If the form of the plant transfer function is known, exact expressions for the limit cycle frequency and amplitude can be derived so that their measurements, assumed error free, can be used to calculate the true parameter value. In the literature, parameter estimation for an assumed form of the plant transfer function has generally been considered for disturbance free cases, except a recently published work of the author. In this paper additional simulation results are reported on exact parameter estimation from relay autotuning under static load disturbances.

Modelling of recycled aggregate concrete-filled steel tube (RACFST) beam-columns subjected to cyclic loading

  • Yang, You-Fu
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.213-233
    • /
    • 2015
  • A nonlinear finite element analysis (FEA) model is presented for simulating the behaviour of recycled aggregate concrete-filled steel tube (RACFST) beam-columns subjected to constant axial compressive load and cyclically increasing flexural loading. The FEA model was developed based on ABAQUS software package and a displacement-based approach was used. The proposed engineering stress versus engineering strain relationship of core concrete with the effect of recycled coarse aggregate (RCA) replacement ratio was adopted in the FEA model. The predicted results of the FEA model were compared with the experimental results of several RACFST as well as the corresponding concrete-filled steel tube (CFST) beam-columns under cyclic loading reported in the literature. The comparison results indicated that the proposed FEA model was capable of predicting the load versus deformation relationship, lateral bearing capacity and failure pattern of RACFST beam-columns with an acceptable accuracy. A parametric study was further carried out to investigate the effect of typical parameters on the mechanism of RACFST beam-columns subjected to cyclic loading.

Performance Analysis of Supercritical Coal Fired Power Plant Using gCCS Simulator

  • Tumsa, Tefera Zelalem;Mun, Tae-Young;Lee, Uendo;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.37-40
    • /
    • 2014
  • Capturing the carbon dioxide emitted from coal-fired power plants will be necessary if targeted reduction in carbon emissions is to be achieved. Modelling and simulation are the base for optimal operation and control in thermal power plant and also play an important role in energy savings. This study aims to analyze the performance of supercritical coal fired power plant through steady and dynamic simulation using a commercial software gCCS. A whole power plant has been modeled and validated with design data of 500 MWe power plant, base and part load operations of the plant were also evaluated, consequently it had been proven that the simulated result had a good agreement with actual operating data. In addition, the effect of co-firng on the plant efficiency and flue gases were investigated using gCCS simulator.

  • PDF

MATLAB/SIMULINK를 이용한 전동기 가변속 구동시스템 모델링 및 시뮬레이션 (Modeling and Simulation with a Variable Speed Drive System of a Electric Motor Using MATLAB/SIMULINK)

  • 정삼용;최연옥;한엄용;오금곤;정수복;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.141-147
    • /
    • 1997
  • The variable speed drive system of a electric motor is popular in industry due to its economical aspect and simplicity of implementation, comparing with a steam turbine or the other engine driven. For a large pumping load like a feedwater pump rated about or more than 20,000㎾, a synchronous motor could be primarily considered. In this paper, we studied the modelling of a variable speed drive system consisted with a load commutated inverter(LCI) and a brushless sailent pole rotor synchronous motor(SM) using MATLAB/SIMULINK. Simulation was performed with a small SM motor parameters.

  • PDF

급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

Analysis of corrugated board panels under compression load

  • Biancolini, M.E.;Brutti, C.;Porziani, S.
    • Steel and Composite Structures
    • /
    • 제9권1호
    • /
    • pp.1-17
    • /
    • 2009
  • This paper is focused on the buckling and post buckling behaviour of rectangular corrugated board panels simply supported and subjected to compression load. The aim of the work is to understand the failure mechanism of investigated structure in order to quantify the effect of design parameters on the strength of a panel of given geometry. Two numerical models were developed adopting the finite element method. In the first one the corrugated board is represented by means of shell elements adopting an equivalent material, in the second the local structure is described in full detail modelling both straight and corrugated layers by means of shell elements and representing the connection between layers by special interface elements. The model correctness was checked by the comparison between out of plane central displacement predicted by the models and the experimental values found in literature. For the same case the effect of panel planarity error was evaluated. Finally a parametric analysis to investigate the effect of design parameters was carried out.

Load bearing capacity reduction of concrete structures due to reinforcement corrosion

  • Chen, Hua-Peng;Nepal, Jaya
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.455-464
    • /
    • 2020
  • Reinforcement corrosion is one of the major problems in the durability of reinforced concrete structures exposed to aggressive environments. Deterioration caused by reinforcement corrosion reduces the durability and the safety margin of concrete structures, causing excessive costs in managing these structures safely. This paper aims to investigate the effects of reinforcement corrosion on the load bearing capacity deterioration of the corroded reinforced concrete structures. A new analytical method is proposed to predict the crack growth of cover concrete and evaluate the residual strength of concrete structures with corroded reinforcement failing in bond. The structural performance indicators, such as concrete crack growth and flexural strength deterioration rate, are assumed to be a stochastic process for lifetime distribution modelling of structural performance deterioration over time during the life cycle. The Weibull life evolution model is employed for analysing lifetime reliability and estimating remaining useful life of the corroded concrete structures. The results for the worked example show that the proposed approach can provide a reliable method for lifetime performance assessment of the corroded reinforced concrete structures.