• Title/Summary/Keyword: load carrier

Search Result 194, Processing Time 0.029 seconds

Dynamic Response of Polyurethane Foam with Density and Temperature Effects (폴리우레탄 폼의 동적 응답에 미치는 밀도 및 온도의 영향)

  • Hwang, Byeong-Kwan;Kim, Jeong-Hyun;Kim, Jeong-Dae;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.291-297
    • /
    • 2019
  • Polyurethane foam is the most efficient, high-performance insulation material, used for liquefied natural gas carrier (LNGC) insulation. Because LNGC is exposed to sloshing impact load due to ship motion of 6 degrees of freedom, polyurethane foam should be sufficient dynamic properties. The dynamic properties of these polyurethane foam depends on temperature and density. Therefore, this study investigates the dynamic response of polyurethane foam for various temperature($25^{\circ}C$, $-70^{\circ}C$, $-163^{\circ}C$) and density($90kg/m^3$, $113kg/m^3$, $134kg/m^3$, $150kg/m^3$) under drop impact test with impact energy of 20J, 50J, and 80J. For dynamic response was evaluated in terms of peak force, peak displacement, absorb energy, and the mechanical property with minimized density effects. The results show the effect of temperature and density on the polyurethane foam material for the dynamic response.

Floating Gas Power Plants

  • Kim, Hyun-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_1
    • /
    • pp.907-915
    • /
    • 2020
  • Specification selection, Layout, specifications and combinations of Power Drives, and Ship motions were studied for FGPP(Floating Gas-fired Power Plants), which are still needed in areas such as the Caribbean, Latin America, and Southeast Asia where electricity is not sufficiently supplied. From this study, the optimal equipment layout in ships was derived. In addition, the difference between engine and turbine was verified through LCOE(Levelized Cost of Energy) comparison according to the type and combination of Power Drives. Analysis of Hs(Significant Height of wave) and Tp(spectrum Peak Period of wave) for places where this FGPP will be tested or applied enables design according to wave characteristics in Brazil and Indonesia. Normalized Sloshing Pressures of FGPP and LNG Carrier are verified using a sloshing analysis program, which is CFD(Computational Fluid Dynamics) software developed by ABS(American Bureau of Shipping). Power Transmission System is studied with Double bus with one Circuit Breaker Topology. A nd the CFD analysis allowed us to calculate linear roll damping coefficients for more accurate full load conditions and ballast conditions. Through RAO(Response Amplitude Operator) analysis, we secured data that could minimize the movement of ships according to the direction of waves and ship placement by identifying the characteristics of large movements in the beam sea conditions. The FGPP has been granted an AIP(Approval in Principle) from a classification society, the ABS.

Development of Smart Carrier with Weight Sensing and Alarm System (무게 감지와 경보시스템을 갖춘 스마트 캐리어 개발)

  • Cho, Jun-Su;Kim, Seung-Kyum;Seo, Dong-Seop;Kwak, Se-Young;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.317-324
    • /
    • 2022
  • In this thesis, in consideration of the functions of general carriers, smart carriers with various convenience functions were studied for supplementation and improvement based on the disadvantages of carriers and inconvenience when using them. Based on the app inventory program, LED and motor locks were installed in carriers through smartphone applications, Bluetooth recognition and control functions that easily control on/off, load cell sensors were installed inside the carriers to detect weight, install Bluetooth and alarms on LCD panels, and prevent theft and loss.

A study on performance comparison of jacket cooling fresh water system for marine diesel engine (선박용 디젤기관의 재킷 냉각청수시스템 성능 비교에 관한 연구)

  • Kim, Duk-Kyung;Lee, Jae-Hyun;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.8-14
    • /
    • 2017
  • Due to the financial crisis in 2008, the world economy collapsed leading to an increase in oil prices and a decrease in freight by shipping. To overcome this crisis, major shipping companies ordered larger ships, changed their trading route and improved operating of ships to overcome deficits. In particular, low-speed navigation was much favored by many companies so that it can reduce fuel consumption. However, the long-term operation of high-speed optimized engines in low-speeds has affected the jacket cooling fresh water (J.C.F.W.) system as they fail to maintain the normal operational temperature. The temperature of J.C.F.W. system dropped leading to low temperature corrosion. As a result, when the engine is operating at minimal load the functioning of existing J.C.F.W cooler is decreased and the use of fresh water generator is substantially limited. Therefore, an improvement in the functioning of J.C.F.W. system is necessary. In this paper, in order to review the improvements required for the operation of J.C.F.W. of low-speed operating marine diesel, an experiment was conducted by comparing and analyzing the results of the main engine J.C.F.W. system of a Panamax class bulk carrier 82k and a Cape class bulk carrier 180k by installing and uninstalling the J.C.F.W. Cooler. Thus, this paper proposed an improved design of the J.C.F.W. system that is suitable for the present low-speed operation.

Structural Analysis of a Suction Pad for a Removable Bike Carrier using Computational and Experimental Methods (탈착식 자전거 캐리어용 흡착 패드의 실험 및 전산적 방법을 활용한 구조해석)

  • Suh, Yeong Sung;Lim, Geun Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.622-628
    • /
    • 2016
  • As the suction pad-supporting bike carrier attached to a car may be subject to an excessive dynamic load due to random vibrations and centrifugal forces during driving, its structural safety is of great concern. To examine this, the finite-element method with a fluid-structure interaction should be used because the pressure on the pad bottom is changed in real time according to the fluctuations of the force or the moment applied on the pad. This method, however, has high computing costs in terms of modeling efforts and software expense. Moreover, the accuracy of computation is not easily guaranteed. Therefore, a new method combining the experiment and computation is proposed in this paper: the bottom pressure and contact area of the pad under varying loads was measured in real time and the acquired data are then used in the nonlinear elastic finite-element calculations. The computational and experimental results obtained with the product under development showed that the safety margin of the pad under the axial loading is relatively sufficient, whereas with an excessive rotational loading, the pad is vulnerable to separation or a local surface damage; hence, the safety margin may not be secured. The predicted contact behavior under the variation of the magnitude and type of the loading were in good agreement with the one from the experiment. The proposed analysis method in this study could be used in the design of similar vacuum pad systems.

Layer 2 Routing with Multi-Spanning Tree Per a Node (노드 당 다중 스패닝 트리를 이용한 2계층 라우팅)

  • Suh, Chang-Jin;Shin, Ji-Soo;Kim, Kyung-Mi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9B
    • /
    • pp.751-759
    • /
    • 2008
  • Carrier Ethernet backbone network integrates distributed layer-2 based metro networks. In this networks, Multiple Spanning Tree Protocol (MSTP) has been uscd as a main routing protocol that allows multiple spanning trees in a network. A better routing protocol called IEEE802.1aq - Shortest Path Bridging (SPB) is recently proposed, that generates the shortest spanning tree per a destination node. As SPB provides a routing path per a destination node, there is no way to adapt network traffic at normal condition. If we are free from the principle of "a spanning tree per a destination node", we can achieve adaptive routing. Based on this philosophy, we propose a new spanning tree based protocol - Edge Node Divided Spanning Tree (ENDIST). ENDIST divides an edge node into sub-nodes as many as connecting links from the node and each sub-node generates a single shortest path tree based on SPB. Depending on network or nodal status, ENDIST chooses a better routing path by flow-basis. This added traffic engineering ability contributes to enhanced throughput and reduced delay in backbone networks. The simulation informs us that ENDIST's throughput under heavy load performs about 3.4-5.8 and 1.5-2.0 times compared with STP's and SPB's one respectively. Also, we verified that ENDIST's throughput corresponds to the theoretical upper bound at half of cases we investigated. This means that the proposed ENDIST is a dramatically enhanced and the close-to-perfect spanning tree based routing schemes.

A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier (LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구)

  • Park, Gi-Beom;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • In this study, the effect of cryogenic liquefied natural gas leakage and loading on liquefied natural gas cargo hold is investigated to observe the performance of the polymer foam material that comprises the cryogenic insulation of the cargo hold. The primary barriers of liquefied natural gas carrier that are in contact with the liquefied natural gas will leak if damage is accumulated, owing to fluid impact loads or liquefied natural gas loading / unloading over a long period. The leakage of the cryogenic fluid affects the interior of the polymer foam, which is a porous closed cell structure, and causes a change in behavior with respect to the working load. In this study, mechanical properties of polyisocyanurate foam specimen, which is a polymer material used as insulation, are evaluated. The performance of the specimens, owing to the cold brittleness and the impregnation effects of the cryogenic fluids, are quantitatively compared and analyzed.

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Impacts of Delivery Vehicle Routing on Different Inventory Strategies and Network Configurations (재고전략 및 네트워크 구성에 따른 배송차량의 운영특성 연구)

  • Won, Min-Su;Gang, Gyeong-U
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.91-106
    • /
    • 2010
  • Recently, interest in supply chain management is rising along with the increasing oil prices and traffic congestion. In particular, people started studying the issue, but realized that advantageous strategies for suppliers and retailers are not always advantageous to a carrier. Therefore, in this study the atuhors set up a simulation scenario to understand delivery vehicle routing problems under various inventory policies, namely Economic Order Quantity (EOQ) and Periodic Order Quantity (POQ) and network configurations. First, the authors made a virtual supply chain. Then they analyzed characteristics of delivery vehicle routing under various inventory policies (EOQ and POQ) and network configurations. As a result, the POQ inventory policy decreases the number of vehicles, the number of drivers, and the service time of vehicles. Also, the centralized network increases the load factor of vehicles and decreases the service time of vehicles. In other words, the centralized network and the POQ inventory policy are better for the carrier. These results show a savings of 15,556,806 won ($13,389.10) in a month: a reduction of 17%.

A Study on Na/Ca Exchange Ratio in Atrial Muscle of Rabbit (토끼 심방근 세포막의 Na/Ca교환 비율에 관한 연구)

  • Kim, Eui-Yong;Hwang, Sang-Ik;Earm, Yung-E;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.291-299
    • /
    • 1989
  • Na and Ca effects on contracture were studied in order to estimate Na/Ca exchange ratio in the isolated atrial muscle of the rabbit. All experiments were performed in tris-buffered Tyrode solution which was being aerated with 100% $O_2\;and\;kept\;at\;37^{circ}C$. To load intracellular $Na^+,\;10{-6}M$ ouabain or K-free solution were used. Contractures were induced by brier exposure of atrial muscle to Tyrode solution containing various concentrations of Ca or of Na. The results obtained were as follows: 1 ) Increasing the extracellular Ca concentration, the amplitude of contracture also increased and was maximum at 8 mM Ca-Tyrode solution. 2) The relationship between extracellular Ca concentrations and relative amplitude of the contractures showed hyperbolic pattern. By using Hill plot, the line has the slope of 1 12 which means the number of Ca binding sites of the carrier in the cell membrane. 3) The amplitude of the contracture was maximum in 0 mM Na-Tyrode solution and decreased in dose dependent manner when the Na concentration increased. 4) When the relationship between extracellular Na concentrations and the amplitude of contractures was expressed as dose-response curve, the curve showed sigmoid pattern. The line with the slope of 2.82 was obtained by using Hill plot. 5) From above all the results, it is suggested that exchange ratio of Na and Ca via Na/ca exchange system in the atrial muscle of rabbit could be 3:1 approximately.

  • PDF