압력 용기 수위 측정 오차 개선에 관한 연구 (A Study on Accuracy Improvement in Measuring Liquid Level inside Pressurized Vessels)

  • 김호열;변승현
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1889-1893
    • /
    • 2010
  • Differential pressure type level measuring systems have been using widely for industrial applications like drum level measurements in power plants. Because of difficulties in specific gravity compensation for vapor and liquid inside the vessel and the sensing lines, this type of measuring systems reveal significant measuring error. In this paper, the major reason causing errors on the differential pressure type level measurement is analyzed and a method of more accurate calculation for specific gravity compensation is introduced.

Time Resolved Measurement of Electric Field Distribution in a Liquid Dielectric

  • Arii, Kiyomitsu;Ihori, Haruo;Fujii, Masaharu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.287-291
    • /
    • 2002
  • Measurement technique of three dimensional electric field distribution in liquid dielectrics have been studied. Kerr effect and computed tomography(CT) method have been used. Measuring time has been shortened by the use of multi-optical systems to less than several milliseconds. Near future, electric field distribution in front of a streamer tip of breakdown would be measured.

Effect of Liquid Crystal Structures on olymerization-induced Phase Separation Behavior by Simultaneous Resistivity and Turbidity Measurement

  • Park, Su-Cheol;Lee, Sang-Sub;Hong, Jin-Who
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.886-889
    • /
    • 2007
  • Photopolymerization and phase separation behavior during the PDLC formation process were investigated by simultaneous resistivity and turbidity measurement. Using this experimental method, we investigated the effect of liquid crystal structure on photopolymerization and phase separation behavior.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정 (Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method)

  • 전용제;김향율;김재형;한은주;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IFS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1V

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정 (Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method)

  • 전용제;김향율;김재형;한은주;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1 V

  • PDF

RADAR level measurement in Joule heated ceramic melter: A novel technique

  • Suneel, G.;Mahashabde, Mukesh;Borkotoky, Ritusmita;Sharma, Nitin Kumar;Pradeep, M.P.;Gayen, J.K.;Pimparkar, H.R.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1176-1180
    • /
    • 2021
  • The current study relates to RADAR (RAdio Detection and Ranging) application for level measurement of vitrified radioactive liquid nuclear waste. The vitrification of radioactive liquid waste is carried out in special equipment called 'Melters'. The study is directed towards the design and frequency modulation used in the level measurement of vitrified waste. More specifically, the RADAR design and frequency used for level measurement in a melter. This level measurement technique can also be used for dynamic vitrification process and can be used to measure the level variations without using any external medium/material and using only electromagnetic waves. Also, this technique is durable and accurate even under the high radioactive environment present inside the melter.

과도액정기법을 이용한 열전달 측정 및 수치해석 (Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis)

  • 홍철현;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

스프레이가 분사되는 표면에서의 액막 두께 분포 측정 (Measurement of liquid film thickness distribution on sprayed surfaces)

  • 김태호;김명호;조형규;김병재
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.33-38
    • /
    • 2023
  • Spray cooling is a method of cooling high-temperature heating elements by spraying droplets. Recently, spray cooling has been proposed for use in next-generation nuclear reactors. When droplets are sprayed onto the outer wall of a heat exchanger tube, a film boiling occurs on the outer wall. Over time, the outer wall temperature decreases, and a liquid film forms on the outer wall, and the heat exchanger outer wall is subsequently cooled by the liquid film. In this case, the liquid film thickness has a great influence on the heat removal performance. In this study, an experimental study was conducted to measure the liquid film thickness distribution in a droplet spray environment. For this purpose, a method using the electrical conductivity of the liquid was adopted.