• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.03 seconds

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Predicting the Effects of Agriculture Non-point Sources Best Management Practices (BMPs) on the Stream Water Quality using HSPF (HSPF를 이용한 농업비점오염원 최적관리방안에 따른 수질개선효과 예측)

  • Kyoung-Seok Lee;Dong Hoon Lee;Youngmi Ahn;Joo-Hyon Kang
    • Journal of Wetlands Research
    • /
    • v.25 no.2
    • /
    • pp.99-110
    • /
    • 2023
  • Non-point source (NP) pollutants in an agricultural landuse are discharged from a large area compared to those in other land uses, and thus effective source control measures are needed. To develop appropriate control measures, it is necessary to quantify discharge load of each source and evaluate the degree of water quality improvement by implementing different options of the control measures. This study used Hydrological Simulation Program-FORTRAN (HSPF) to quantify pollutant discharge loads from different sources and effects of different control measures on water quality improvements, thereby supporting decision making in developing appropirate pollutant control strategies. The study area is the Gyeseong river watershed in Changnyeong county, Gyeongsangnam-do, with agricultural areas occupying the largest proportion (26.13%) of the total area except for the forest area. The main pollutant sources include chemical and liquid fertilizers for agricultural activities, and manure produced from small scale livestock facilities and applied to agriculture lands or stacked near the facilities. Source loads of chemical fertilizers, liquid fertilizers and livestock manure of small scale livestock facilities, and point sources such as municipal wastewater treatment plants (WWTPs), community WWTPs, private sewage treament plants were considered in the HSPF model setup. Especially, NITR and PHOS modules were used to simulate detailed fate and transport processes including vegitation uptake, nutrient deposition, adsorption/desorption, and loss by deep percolation. The HSPF model was calibrated and validated based on the observed data from 2015 to 2020 at the outlet of the watershed. The calibrated model showed reasonably good performance in simulating the flow and water quality. Five Pollutants control scenarios were established from three sectors: agriculture pollution management (drainge outlet control, and replacement of controlled release fertilizers), livestock pollution management (liquid fertilizer reduction, and 'manure management of small scale livestock facilities) and private STP management. Each pollutant control measure was further divided into short-term, mid-term, and long-term scenarios based on the potential achievement period. The simulation results showed that the most effective control measure is the replacement of controlled release fertilizers followed by the drainge outlet control and the manure management of small scale livestock facilities. Furthermore, the simulation showed that application of all the control measures in the entire watershed can decrease the annual TN and TP loads at the outlet by 40.6% and 41.1%, respectively, and the annual average concentrations of TN and TP at the outlet by 35.1% and 29.2%, respectively. This study supports decision makers in priotizing different pollutant control measures based on their predicted performance on the water quality improvements in an agriculturally dominated watershed.

Design and Experimental Verification of Uni-Injector Using Gas Methane and Lox as Propellants (가스메탄/액체산소를 추진제로 하는 단일 인젝터 설계 및 실험적 검증)

  • Jeon, Jun Su;Min, Ji Hong;Jang, Ji Hun;Ko, Young Sung;Kim, Sun Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.275-283
    • /
    • 2013
  • An injector that uses methane gas ($CH_4$) and liquid oxygen ($LO_x$) as propellants was designed to verify the combustion characteristics of an engine that uses methane, which is one of the next-generation propellants. A swirl/shear coaxial-type injector was used, and flow analysis was performed using Fluent to determine the main design parameters of the injector. A hydraulic test was performed to understand the atomization and spray pattern characteristics of the injector. Next, a combustion test was performed at the design point to understand the ignition and combustion stability. Additional combustion tests were performed according to the O/F ratio to investigate the combustion characteristics and stabilities using the characteristic exhaust velocity ($C^*$) and fluctuation of the chamber pressure. The experimental results showed that the combustion efficiency was greater than 90%, and the pressure fluctuation was lower than 2% under all conditions.

Simultaneous determination of preservatives in sausages using liquid chromatography with electrospray ionization tandem mass spectrometry (LC-MS/MS를 이용한 소시지 중 보존료 동시분석)

  • Koh, Ba-Ra-Da;Kim, Ji-Yeon;Jang, Mi-Sun;Seo, Doo-Ri;Jung, Bo-Ram;Shin, Ji-Hyun;Lim, Jin-Taek;Kim, Yong-Hwan;Kim, Eun-Sun
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • A simultaneous determination method was developed for nine preservatives (benzoic acid, sorbic acid, dehydroacetic acid, methyl-, ethyl-, isopropyl-, propyl-, isobutyl- and butyl-parabens) in sausage by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Each parameter was established by multiple reaction monitoring in negative mode. Separation was achieved on a phenyl-hexyl ($2.5{\mu}m$, $2.1{\times}150mm$, Waters) with A-20 mM ammonium acetate containing 0.1% acetic acid in water, B-Acetonitrile as mobile phase with gradient mode at a flow rate of 0.3 mL/min. The developed method was validated for specificity, linearity, accuracy and precision in sausages samples. Linearity was over 0.998 with calibration curve of the mixed standards. The mean recoveries from sausages fortified at the level of 2.0~10.0 mg/L were in range of 98.60~109.16% with RSDs lower than 8.93%. The limits of detection (LOD) and the limits of quantification (LOQ) were in the range between 0.0003~0.085 mg/L and 0.01~0.257 mg/L, respectively. Intra-day precision and inter-day precision were 0.45~6.16% and 2.81~13.33%, respectively. Using presently developed determination method, 33 field sausage samples from Gwangju city in Korea were screened over nine preservatives. As a result, no preservatives were detected in all samples.

Production of Fluorosilicic Acid from Phosphoric Acid Slurry of a Fertilizer Manufacturing Plant (비료공장의 인산 슬러리로부터 규불산 제조)

  • Kim, Se-Won;Moon, Woo-Kyun;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.926-933
    • /
    • 2012
  • Phosphoric acid used for the production of phosphate fertilizers is synthesized by the reaction of phosphate rock and sulfuric acid. As the reaction is exothermic, yield of phosphoric acid is poor at elevated temperature. Therefore, enhancement in its yield requires the process temperature be maintained by releasing the vapor ($80^{\circ}C$) containing HF and SiF4 through a vacuum cooler. However, these valuable resources; Fand Si, which can be utilized for the manufacture of refrigerant and polysilicon, respectively, are being wasted in the treatment process. We performed lab-scale experiments to estimate the amount of recoverable H2SiF6, a by-product of phosphoric acid manufacturing process. The experimental results showed a decrease of fluorine concentration by 0.12wt% in the liquid phase. Preliminary estimation showed a possible recovery of 5,509 ton/yr of fluorine considering the scale of the fertilizer manufacturing plant. Furthermore, field-scale experiment showed that H2SiF6 could be enriched in liquid phase from 0.35wt% to 7.33wt% and the vapor flow-rate from vacuum cooler was estimated at $51,000m^3/hr$. Anew, the efficiency of fluorine recovery in the pilot-scale experiment was found to be 76.74% and the production of H2SiF6 was estimated at 5,340 ton/yr.

HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

  • Ang, Lee Fung;Yam, Mun Fei;Fung, Yvonne Tan Tze;Kiang, Peh Kok;Darwin, Yusrida
    • Journal of Pharmacopuncture
    • /
    • v.17 no.4
    • /
    • pp.36-49
    • /
    • 2014
  • Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of $35^{\circ}C$, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of $0.00488-200{\mu}g/mL$, $0.625-320{\mu}g/mL$, $0.07813-320{\mu}g/mL$ and $0.03906-320{\mu}g/mL$, respectively. The limits of detection and quantification, respectively, were 0.00488 and $0.03906{\mu}g/mL$ for quercetin, 0.62500 and $2.50000{\mu}g/mL$ for bisdemethoxycurcumin, 0.07813 and $0.31250{\mu}g/mL$ for demethoxycurcumin, and 0.03906 and $0.07813{\mu}g/mL$ for curcumin. The percent relative intra day standard deviation (% RSD) values were $0.432-0.806{\mu}g/mL$, $0.576-0.723{\mu}g/mL$, $0.635-0.752{\mu}g/mL$ and $0.655-0.732{\mu}g/mL$ for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were $0.323-0.968{\mu}g/mL$, $0.805-0.854{\mu}g/mL$, $0.078-0.844{\mu}g/mL$ and $0.275-0.829{\mu}g/mL$, respectively. The intra day accuracies were 99.589%-100.821%, 98.588%-101.084%, 9.289%-100.88%, and 98.292%-101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the inter day accuracy were 99.665%-103.06%, 97.669%-103.513%, 99.569%-103.617%, and 97.929%-103.606%, respectively. Conclusion: The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of commercial Chinese medicine products containing the flour flavonoids as their principle components in the extracts.

Studies on Goucoalkaloids in Plants I. High Performance Liquid Chromatographic Analysis of Glucoalkaloids in Periderm and Cortex of Potato (Solanum tuberosum var. May Queen) (식물체(植物體)의 Glucoalkaloids 에 관(關)한 연구(硏究) 제1보(第1報) 고속액체(高速液體)크로마토그래피에 의한 감자(Solanum tuberosum var. May Queen)의 피층부(皮層部) 및 수질부(髓質部)의 Glucoalkaloids 측정(測定))

  • Hwang, Chun-Sun;Lee, Sung-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.11 no.3
    • /
    • pp.1-4
    • /
    • 1982
  • By high performance liquid chromatography, separation and quantification of glucoalkaloids $({\alpha}-chaconine$and${\alpha}-solanine)$ from potato (Solanum tuberosum, var. May Queen) was established using periderm and cortex. $Nucleosil-NH_2\;(10{\mu}m)$ was packed in two stainless steel columns ($4.0\;ID{\times}15\;cm$ and $4.0\;ID{\times}25\;cm$) which were connected in sequence and eluted with the mixture of tetrahydrofuran, phosphoric acid buffer and acetonitrile (50 : 25 : 25, v/v/v) at the flow rate of 1ml/min. and the absorbance were read at 208 nm. Retention time was 6.92 min. for ${\alpha}-chaconine$ and 10.96 min. for ${\alpha}-solanine$ with complete separation. This method took 12 min. per sample and seemed best. ${\alpha}-Chaconine$ and ${\alpha}-solanine$ were found much in periderm than in cortex.

  • PDF

Determination of Fructooligosaccharides and Raffinose in Infant Formula by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSC를 이용한 조제분유 중 fructooligosaccharides 및 raffinose 분석)

  • Shin, Man-Sub;Park, Jae-Woo;Cho, Mi-Ran;Song, Sung-Ok;Kim, Chun-Sun;Choi, Chun-Bae;Lee, Seoung-Won;Lee, Ki-Woong;Chang, Chi-Hoon;Kwak, Byung-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.725-729
    • /
    • 2006
  • A method was developed for the determination of fructooligosaccharides and raffinose contents in infant formula. The samples were extracted and analyzed by liquid chromatography equipped with carbohydrate column and evaporative light scattering detector. The mobile phase used for the gradient mode was water-acetonitrile, at a flow rate of 1.0mL/min. The method showed a mean recovery of 95-99%, the relative standard deviation obtained in the precision study was 0.774-8.982%, the quantification and detection limits were 25-50mg/L.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.