• Title/Summary/Keyword: liquid column

Search Result 1,373, Processing Time 0.038 seconds

Peptide Production from the Washing Liquid of the Fish Paste of Alaska pollak (Theragria chalcogramma) by Immobilized Enzyme (고정화 효소를 이용한 명태고기풀 수세액으로부터 Peptide 생산에 관한 연구)

  • SHIN Suk-U;SUETSUNA Kunio
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.466-472
    • /
    • 1997
  • Peptides separated from fish paste washing liquid of an Alaska pollak (Theragria chalcogramma) were purified and characterized. The fish paste washing liquid (supernatant) was separated by centrifugation of fish paste homogenate. The fish paste washing liquid of $0.5\%$ concentration was hydrolyzed for 24 hour at $50^{\circ}C$ by immobilized protease in bioreactor and decomposing liquid of protein having $50\%$ decomposing rate (OPA method) was obtained. The crude peptide fractions were obtained from this liquid by Dowex 50w $(H^+)$ column chromatograpy. Purified peptides (SP-fraction peptides) were fractionated by using SP-Sepadex C-25 $(H^+)$ column chromatography. Molecular weights and amino acid compositions of these peptides were estimated by Sephadex G-50 column chromatography and HPLC, respectively. when the washed peptides was eluated with $0.6\~0.9\%\;and\;1.2\~2.0\%$ of NaCl, peptides composed of weakly basic amino acids and strongly basic amino acid were respectively eluted. Molecular weights of each peptide fractions showed the broad distribution from 1,000 Da to 3,000 Da in the order of SP-4>SP-3>SP-2>SP-1. Peptides contained a large quantity of glycine, arginine, glutamic acid, and alanine in the washed peptide and its SP-tractions, respectively.

  • PDF

Separation and Purification of Lipase Inhibitory Peptide from Fermented Milk by Lactobacillus plantarum Q180

  • Kim, Seulki;Lim, Sang-Dong
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.87-95
    • /
    • 2020
  • In this study, we separated and purified lipase inhibitory peptide from fermented milk by Lactobacillus plantarum Q180 with the aim of developing a new functional anti-lipase activity yogurt product. L. plantarum 180 was inoculated into 10% reconstituted skimmed milk and incubated at 37℃ until the pH of the culture reached pH 4.4. The lipase activity was measured using porcine pancreatic lipase. The lipase inhibitory peptides were gradually isolated by ultrafiltration, reversed phase column chromatography (RPC), reversed phase high-performance liquid chromatography (RP-HPLC), and gel permeation high-performance liquid chromatography (GP-HPLC) from the fermented milk by L. plantarum Q180. An ODS-AQ column was used for the RPC, a Vydac C18 column for the RP-HPLC, and a Superdex Peptide HR column for the GP-HPLC. The peptide was composed of Asp, Thr, Ile, Ser, Ala, and Gln, and the anti-lipase activity (IC50) was 2,817 ㎍/mL.

Axial and Radial Gas Holdup in Bubble Column Reactor

  • Wagh, Sameer M.;Ansari, Mohashin E. Alam;Kene, Pragati T.
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.1703-1705
    • /
    • 2014
  • Bubble column reactors are considered the reactor of choice for numerous applications including oxidation, hydrogenation, waste water treatment, and Fischer-Tropsch (FT) synthesis. They are widely used in a variety of industrial applications for carrying out gas-liquid and gas-liquid-solid reactions. In this paper, the computational fluid dynamics (CFD) model is used for predicting the gas holdup and its distribution along radial and axial direction are presented. Gas holdup increases linearly with increase in gas velocity. Gas bubbles tends to concentrate more towards the center of the column and follows a wavy path.

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Identification of Actinomycins by High Performance Liquid Chromatography and Fast Atom Bombardment Mass Spectrometry

  • Cho, Seong-Eun;Goo, Yang-Mo;Kim, Kyoung-Ja
    • Archives of Pharmacal Research
    • /
    • v.17 no.6
    • /
    • pp.424-427
    • /
    • 1994
  • An acinomycin complex isolated from culture broth of a soil microorganism, SNUS 9305-011 has been examined by High performance liquid chromatography (HPLC). From the analysis of the fractions obtained by column chromatography of the ethyl acetate extract, three actinomycin components are confimed . The HPLC analysis is carried out with a CN-bonded nucleosil column. Comparison of the retention times of the components with those of actinomycin D, C complex, $X_{o{\beta}$, and V and suggests that they are different actinomycins. FBA mass spectra fo the coponents also shows different molecular ions from those of standards and other reported actionbmycins. The present work has demonstrated that actinomycin components can be separated by a CN-bonded HPLC column, and that ocmparison of their HPLC chormatograms with authentic smaples and information on their molecular ions can be successfully employed for indentification of actionmycins.

  • PDF

Two new relationships for slip velocity and characteristic velocity in a non-center rotating column

  • Torkaman, Rezvan;Heydari, Mehran;Cheshmeh, Javad Najafi;Heydari, Ali;Asadollahzadeh, Mehdi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2809-2818
    • /
    • 2022
  • In this investigation work, liquid-liquid extraction (L.L.E) through three distinctive frameworks have been examined for assurance of slip velocity (S.V), and characteristic velocity (C.V) in a non-center rotating column (N.C.R.C) with a wide extend of factors. Three double frameworks with distinctive interfacial tension comprising of toluene-water (high interfacial tension), n-butyl acetate-water (medium interfacial tension), and n-butanol-water (low interfacial tension) were investigated for tests. Two common relationships for the expectation of S.V and C.V, including phase stream rates, rotor speed, column geometry additionally physical properties, are displayed. The recommended relationships were compared with test information gotten from the writing and the display examination. Findings of this study, the present proposed correlations are more accurate than those previously reported.

A Study on the Characteristics of Liquid Jet in Crossflows Using Elliptical Nozzles (타원형 노즐을 이용한 횡단류 유동에서 액체제트 특성 연구)

  • Song, Yoonho;Hwang, Donghyun;Ahn, Kyubok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.320-324
    • /
    • 2017
  • Effect of elliptical orifice on the spray characteristics of liquid jet ejecting into subsonic crossflows were experimentally studied. Circular/elliptical plain-orifice injectors, which had different ratios of the orifice length to diameter and major axis to minor axis, were used for transverse injection. Compared with the previous research, breakup lengths of elliptical nozzles are shorter than circular nozzles at all experimental condition. Cavitation/hydraulic flip are considered as a reduction in the breakup length at all circular/elliptical nozzle. In the case of liquid column trajectories, major axis which was placed to the crossflows, increases the frontal area of the liquid column exposed to the crossflows. Hence, the aerodynamic force exerted on the jet is increased and the penetration depth is reduced.

  • PDF

Nonlinear Model Based Control of Two-Product Reactive Distillation Column

  • Lee, In-Beum;Han, Myung-Wan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.50.3-50
    • /
    • 2001
  • Nonlinear feedback control scheme for reactive distillation column has been proposed. The proposed control scheme is derived in the framework of Nonlinear Internal Model Control. The product compositions and liquid and vapor flow rates in sections of the reactive distillation column are estimated from selected tray temperature measurements by an observer. The control scheme is applied to example reactive distillation column in which two products are produced in a single column and the reversible reaction A + B = C + D occurs. The relative volatilities are favorable for reactive distillation so that the reactants are intermediated boilers between the light product C and the heavy product D. Ideal physical properties, kinetics and ...

  • PDF

An Experimental Study on the Trajectory Characteristics of Liquid Jet with Canted Injection Angles in Crossflow (수직분사제트에서 다양한 분사각도의 분무궤적 특성에 대한 실험적 연구)

  • Kim, Min-Ki;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.6
    • /
    • pp.38-47
    • /
    • 2008
  • The liquid column and spray trajectory have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle were varied to provide of jet operation conditions. The Pulsed Shadowgraph Photography and Planar Liquid Laser Induced Fluorescence technique was used to determine the injection characteristics in a subsonic crossflow of air. And the mainly objectives of this research was to get a empirical formula of liquid column and spray region trajectory with forward and reversed injection of air stream. As the result, This research has been shown that each trajectories were spatially dependent on air-stream velocity, fuel injection velocity, various injection angle, and normalized injector exit diameter. Furthermore, the empirical formula of liquid column trajectories has been some different of drag coefficient results between forward and reversed angled injection.

Analysis of Heterocyclic Amines in Human Urine Using Multiple Solid-Phase Extraction by Liquid Chromatography/Mass Spectrometry

  • Cha, Hyun-Jeong;Kim, Nam-Hee;Jeong, Eun-Kyung;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2322-2328
    • /
    • 2010
  • A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.