• Title/Summary/Keyword: liquid chromatography mass spectrometry

Search Result 888, Processing Time 0.026 seconds

Analysis of Death Due to Poisoning in the National Capital Region (2014-2016) (수도권 부검시료에서 중독사 관련 사용물질 현황(2014-2016))

  • Park, Meejung;Park, Jongsin;Lee, Sangki;In, Sangwhan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.2
    • /
    • pp.101-106
    • /
    • 2017
  • Purpose: This study examined the patterns of drugs, poisons, and chemicals detected in autopsy samples performed in the Seoul Institute and other regional forensic offices of the National Forensic Service (NFS) between 2014 and 2016. Methods: The investigation carried out using the laboratory information management system. Forensic toxicological identification and quantitation were performed in autopsy samples, including heart blood, peripheral blood, liver, kidney, vitreous humor and etc. Gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to analyze the drugs and poisons. Results: Forensic autopsies were performed on 9,674 cases in this period. Based on the autopsy reports, 699 cases (7.2%) were considered as unnatural deaths caused by fatal intoxication. The number of male deaths was higher than that of female deaths, with the age of 50-59 being the most common age group. Conclusion: Drugs comprised the largest number of deaths due to poison, followed by alcohol, agrochemicals, drug with alcohol, carbon monoxide, and cyanide, in that order. Zolpidem was the most frequently used drug in all drug-related intoxication cases.

On the Pyrolysis of Polymers II. Identification of the Products from Polymer Pyrolysis by Gas Chromatography (高分子物質의 熱分解에 關한 硏究 (第2報) Gas Chromatography 에 依한 熱分解生成物의 檢索)

  • Chwa-Kyung Sung
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.106-114
    • /
    • 1963
  • The products from polymer pyrolysis at $450^{\circ}$ are cooled with ice, then liquid and gaseous portions are analysed by gas chromatography. Di-2-ethyl hexyl sebacate column, silicone oil column, silica gel column and tetraethyleneglycol dimethylether column, which was most effective for the separation of hydrocarbon gases, are used. Identification of isomers could be secured more effectively by gas chromatography than mass spectrometry. Elucidation of the mechanism for thermal decomposition of polymers could be done through the identification of pyrolysis products. Although more extensive work is needed, some patterns of polymer pyrolysis are discussed.

  • PDF

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Comparison of rosiglitazone metabolite profiles in rat plasma between intraperitoneal and oral administration and identifcation of a novel metabolite by liquid chromatography-triple time of flight mass spectrometry (액체크로마토그라피-삼중비행시간질량분석기를 사용한 rosiglitazone의 복강 및 경구투여 후 대사체 비교 분석)

  • Park, Minho;Na, Sook-Hee;Lee, Hee-Joo;Shin, Byung-Hee;An, Byung-Jun;Shin, Young G.
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.132-138
    • /
    • 2015
  • Rosiglitazone metabolites in rat plasma were analyzed after intraperitoneal and oral administration to rats. Seven metabolites (M1-M7) were detected in rat plasma (IP and PO), and the structures were confirmed using liquid chromatography-triple time of flight (TOF) mass spectrometry; as a result, the most abundant metabolite was M5, a de-methylated rosiglitazone. Other minor in vivo metabolites were driven from monooxygenation and demethylation (M2), thiazolidinedione ring-opening (M1, M3), mono-oxygenation (M4, M7), and mono-oxygenation followed by sulfation (M6). Among them, M1 was found to be a 3-{p-[2-(N-methyl-N-2-pyridylamino)ethoxy]phenyl}-2-(methylsulfinyl)propionamide, which is a novel metabolite of rosiglitazone. There was no significant difference in the metabolic profiles resulting from the two administrations. The findings of this study provide the first comparison of circulating metabolite profiles of rosiglitazone in rat after IP and PO administration and a novel metabolite of rosiglitazone in rat plasma.

Isolation and Identification of Major Component from Roots of Potentilla chinensis (딱지꽃(Potentilla chinensis) 뿌리 추출물의 주요성분 분리동정)

  • Jung, Hae Soo;Kim, Hyoung Shik;Lee, Jeong Hun;Moh, Seo Jin;Yeo, Jin Hui;Park, Gi won;Moh, Sang Hyun
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.1
    • /
    • pp.5-7
    • /
    • 2016
  • One of oriental medicinal plants, Potentilla chinensis, has been used for anti-inflammation, hemostatic, decryption, and antipyretic. Especially, a root of Potentilla chinensis was used as important material for oriental medication. Although several kinds of bioactive component of Potentilla chinensis extract from stems and leaves were identified, the major component of Potentilla chinensis from roots is not well established. In this study, the root of Potentilla chinensis was extracted in different solvent system and analyzed by high performance liquid chromatography (HPLC). According to HPLC analysis, a major component was isolated and its physicochemical properties were evaluated by mass spectrometry and nuclear magnetic resonance. Based on these results, isolated compound was identified as 2,3,8-Tri-O-methylellagic acid. And quantification of 2,3,8-Tri-O-methylellagic acid with different extraction solvent system was performed for industrial application.

Determination of Tiapride in Human Plasma Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry

  • Moon, Ya;Paek, In-Bok;Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Park, Hyoung-Geun;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.9
    • /
    • pp.901-905
    • /
    • 2004
  • A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric(HILIC-MS/MS) method for the determination of tiapride in human plasma was developed. Tiapride and internal standard, metoclopramide were extracted from human plasma with dichloromethane at basic pH and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The ana-Iytes were detected using an electrospray ionization tandem mass spectrometry in the multi-ple-reaction-monitoring mode. The standard curve was linear (r=0.999) over the concentration range of 1.00-200 ng/mL. The coefficient of variation and relative error for intra- and inter-assay at three QC levels were 6.4∼8.8% and -2.0∼3.6%, respectively. The recoveries of tiapride ranged from 96.3 to 97.4%, with that of metoclopramide (internal standard) being 94.2%. The lower limit of quantification for tiapride was 1.00 ng/mL using 1 00 $\mu$L of plasma sample.

A Study on the Simultaneous Determination of Residual Zeranol, Zearalenone and Their Metabolites in Beef by Gas Chromatography/Mass Spectrometry (Gas Chromatography/Mass Spectrometry에 의한 우육 중의 잔류 Zeranol, Zearalenone 및 그 대사산물들의 동시 분석법에 대한 연구)

  • 이은섭;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • A Simultaneous determination method was improved for the determination and confirmation of zeranol, zearalenone, as well as their isomers and metabolites, in beef. The analytes were extracted from tissue by CH3CN, hydrolyzed enzymatically(for glucuronide conjugates), cleaned up by a strong basic anion exchange resin combined with a liquid/liquid partitioning, derivatized using MSTFA and confirmed, quantified by GC/MS/SIM with a internal standard, zearalane. The results were as follows : (1) all the estrogens were separated on the GC/MS chromatogram under the extraction method and the chromatographic conditions improved, the retention times of zearalane-TMS2, zearalanone-TMS2, zearalenone-TMS2, zeranol-TMS3, taleranol-TMS3, and $\alpha$-zearalenol-TMS3, $\beta$-zearalenol-TMS3, were 18.49, 19.44, 19.63, 19.71, 19.79 and 19.99, 20.08 minutes, respectively. (2) The calibration curves of residual zeranol, zearalenone and their metabolites showed constantly linear(r=0.99) in the range of 5~20 ng. The minimum detection concentration of residual zeranol, zearalenone and their metabolites was 1 ppb. (3) The total average recovery of residual zeranol, zearalenone and their metabolites from spiked beef was 60.2%(CV=29.7%) at the 1 ppb and 63.5%(CV=26.5) at the 2 ppb, 72.9%(CV=18.2%) at the 4 ppb. (4) The preservation method for 6 estrogens was improved for the fast running time(21 min) and MSTFA was utilized for derivatizing 6 estrogens for improvement of recovery, for good resolution, for characteristic mass spectra unlike Jose's method and Tina's method. The utilization of zearalane as internal standard showed good quantification result for zeranol, zearalenone, as well as their isomers and metabolites, in beef.

  • PDF

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

Electrospray-Mass Spectrometric Analysis of Plasma Pyrophosphates Separated on a Multi-Modal Liquid Chromatographic Column

  • Lee, Su-Hyeon;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.92-95
    • /
    • 2011
  • Pyrophosphates are the key intermediates in the biosynthesis of isoprenoids, and their concentrations could reveal the benefits of statins in cardiovascular diseases. Quantitative analysis of five pyrophosphates, including isopentenyl pyrophosphate (IPP), dimethylallyl pyrophosphate (DMAPP), geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), and geranylgeranyl pyrophosphate (GGPP), was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative ionization mode. After dilution with methanol, samples were separated on a 3 ${\mu}m$ particle multi-modal $C_{18}$ column ($50{\times}2$ mm) and quantified within 10 min. The gradient elution consists of 10 mM ammonium bicarbonate and 0.5% triethylamine (TEA) in water and 0.1% TEA in 80% acetonitrile was used at the flow rate of 0.4 mL/min. Overall recoveries were 51.4-106.6%, while the limit of quantification was 0.05 ${\mu}g$/mL for GPP and FPP and 0.1 ${\mu}g$/mL for IPP, DMAPP, and GGPP. The precision (% CV) and accuracy (% bias) of the assay were 1.9-12.3% and 89.6-111.8%, respectively, in 0.05-10 ${\mu}g$/mL calibration ranges ($R^2$ > 0.993). The devised LC-MS/MS technique with the multi-modal $C_{18}$ column can be used to estimate the biological activity of pyrophosphates in plasma and may be applicable to cardiovascular events with cholesterol metabolism as well as the drug efficacy of statins.

Purification and Characterization of an Angiotensin Converting Enzyme Inhibitor from Squid Ink

  • Kim, So-youn;Kim, Sun-hye;Song, Kyung-Bin
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.135.2-135
    • /
    • 2003
  • Angiotensin converting enzyme (ACE) converts angiotensin I into angiotensin II by cleaving C-terminal dipeptide of angiotensin I and inactivates bradykinin. ACE inhibitors have been screened from various food sources since the inhibitors decrease blood pressure. Therefore, in this study, an ACE inhibitor was isolated and purified from squid ink using membrane filtration, gel permeation chromatography, normal phase HPLC, and fast protein liquid chromatography. The purified inhibitor was identified to be a molecular mass of 294 by mass spectrometry, and to have IC$\sub$50/ value of 4.9 $\mu\textrm{g}$/mL.

  • PDF