• 제목/요약/키워드: linear source

검색결과 1,138건 처리시간 0.031초

A NOVEL UNSUPERVISED DECONVOLUTION NETWORK:EFFICIENT FOR A SPARSE SOURCE

  • Choi, Seung-Jin
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1998년도 가을 학술발표논문집 Vol.25 No.2 (2)
    • /
    • pp.336-338
    • /
    • 1998
  • This paper presents a novel neural network structure to the blind deconvolution task where the input (source) to a system is not available and the source has any type of distribution including sparse distribution. We employ multiple sensors so that spatial information plays a important role. The resulting learning algorithm is linear so that it works for both sub-and super-Gaussian source. Moreover, we can successfully deconvolve the mixture of a sparse source, while most existing algorithms [5] have difficulties in this task. Computer simulations confirm the validity and high performance of the proposed algorithm.

  • PDF

Linear Ion Source를 이용한 Anode Voltage 변화에 따른 DLC 박막특성 (Effect of Anode Voltage on Diamond-like Carbon Thin Film Using Linear Ion Source)

  • 김왕렬;정우창;조형호;박민석;정원섭
    • 한국표면공학회지
    • /
    • 제42권4호
    • /
    • pp.179-185
    • /
    • 2009
  • Diamond-like carbon(DLC) films were deposited by linear ion source(LIS)-physical vapor deposition method changing the anode voltages from 800 V to 1800 V, and characteristics of the films were investigated using residual stress tester, nano-indentation, micro raman spectroscopy, scratch tester and Field Emission Scanning Electron Microscope(FE-SEM). The results showed that the residual stress and hardness increased with increasing the ion energy up to anode voltage of 1400 V. It was also found that the content of $SP^3$ carbon increased with increasing the anode voltage $SP^3/SP^2$ ratio through investigation of $SP^3/SP^2$ ratio by the micro-raman analysis. From these results, it can be concluded that the physical properties of DLC films such as residual stress and hardness are increased with increasing the anode voltage. These results can be explained that 3-dimensional cross-links between carbon atoms and Dangling bond are enhanced and the internal compressive stress also increased with increasing the anode voltage. The optimal anode voltage is considered to be around 1400 V in these experimental conditions.

선형다변회귀모델과 LP-PSOLA 합성방식을 이용한 음성변환 (Voice Conversion Using Linear Multivariate Regression Model and LP-PSOLA Synthesis Method)

  • 권홍석;배건성
    • 한국음향학회지
    • /
    • 제20권3호
    • /
    • pp.15-23
    • /
    • 2001
  • 본 논문에서는 임의의 사람이 발성한 음성을 마치 다른 사람이 발성한 것처럼 들리도록 하는 음성변환 기술에 대하여 설명하고, 화자간의 성도 특성과 여기신호 특성 파라미터 변환을 독립적으로 수행하기 위한 변환방법을 실험한다. 성도 특성 파라미터 변환은 입력되는 음성신호에서 LPC (Linear Predictive Cofficient)켑스트럼을 추출하여 선형다변회귀모델에 적용하여 수행하고, 여기신호 특성 파라미터 변환은 잔차신호를 추출하여 LP-PSOLA (Linear Predictive-Pitch Synchronous Overlap and Add) 합성방식을 이용한 화자간의 평균 피치주기 변환으로 수행된다. 실험결과는 선형다변회귀모델과 LP-PSOLA 합성방식을 이용하여 변환된 음성이 대상화자의 음성에 유사함을 보여준다

  • PDF

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • 임유봉;최원호;이승훈;한우용;이종현;이상균;하정민;김종훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

Monte Carlo 방법을 이용한 대기오염 배출률 예측의 불확실성 평가 (Uncertainty Evaluation of the Estimated Release Rate for the Atmospheric Pollutant Using Monte Carlo Method)

  • 정효준;김은한;서경석;황원태;한문희
    • 한국환경과학회지
    • /
    • 제15권4호
    • /
    • pp.319-324
    • /
    • 2006
  • Release rate is one of the important items for the environmental impact assessment caused by radioactive materials in case of an accidental release from the nuclear facilities. In this study, the uncertainty of the estimated release rate is evaluated using Monte Carlo method. Gaussian plume model and linear programming are used for estimating the release rate of a source material. Tracer experiment is performed at the Yeoung-Kwang nuclear site to understand the dispersion characteristics. The optimized release rate was 1.56 times rather than the released source as a result of the linear programming to minimize the sum of square errors between the observed concentrations of the experiment and the calculated ones using Gaussian plume model. In the mean time, 95% confidence interval of the estimated release rate was from 1.41 to 2.53 times compared with the released rate as a result of the Monte Carlo simulation considering input variations of the Gaussian plume model. We confirm that this kind of the uncertainty evaluation for the source rate can support decision making appropriately in case of the radiological emergencies.

Linear Interpolation Transition of Character Animation for Immediate 3D Response to User Motion

  • Lim, Sooyeon
    • International Journal of Contents
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2015
  • The purpose of this research is to study methods for performing transition that have visual representation of corresponding animations with no bounce in subsequently recognized user information when attempting to interact with a virtual 3D character in real-time using user motion. If the transitions of the animation are needed owing to a variety of external environments, continuous recognition of user information is required to correspond to the motion. The proposed method includes linear interpolation of the transition using cross-fades and blending techniques. The normalized playing time of the source animation was utilized for automatically calculating the transition interpolation length of the target animation and also as the criteria in selecting the crossfades and blending techniques. In particular, in the case of blending, the weighting value based on the degree of similarity between two animations is used as a blending parameter. Accordingly, transitions for visually excellent animation are performed on interactive holographic projection systems.

유기반도체 박막증착을 위한 선형증착원의 유체유동해석 (Analysis of Fluid Flow in the Linear Cell Source for Organic Semiconductor Thin Film Deposition)

  • 곽인철;양영수;최범호;김영미
    • 한국정밀공학회지
    • /
    • 제26권10호
    • /
    • pp.74-80
    • /
    • 2009
  • This paper presents a study on fluid flow analysis of organic semiconductor thin film deposition process using the computational numerical method. In the production process, the thickness of deposited organic thin film depends on distribution of nozzle size in the linear cell system, so we analyze to decide the optimal nozzle system for uniform thickness of organic thin film. The results of deposited thickness of thin film by numerical analysis are in good agreement with those of the experimental measurements.

아날로그 - 디지털 스위칭 혼합형 저 리플- 고 효율 Li-Ion 배터리 충전기 (Analog-Digital Switching Mixed Mode Low Ripple - High Efficiency Li-Ion Battery Charger)

  • 정상화;우영진;김남인;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2531-2533
    • /
    • 2001
  • This paper describes a low noise and high efficiency analog-digital switching mixed mode battery charger for production facilities of Li-Ion batteries. The requirements for battery chargers for production facilities are very strict. The accuracy of output voltage and output current should be below 0.1% with very low ripple current. Therefore analog type linear regulators are widely used for battery charger in spite of their inefficiency and bulkiness. We combined linear regulator as a voltage source with digital switching converter as a dependent current source. Low current ripple and high accuracy are obtained by linear regulator while high efficiency is achieved by digital switching converter. Experimental results show that proposed method has 0.1% ripple and 90% efficiency at an output current of 1A for a battery voltage of 4V.

  • PDF

Roll-to-Roll Barrier Coatings on PET Film by Using a Closed Drift Magnetron Plasma Enhanced Chemical Vapor Deposition

  • Lee, Seunghun;Kim, Jong-Kuk;Kim, Do-Geun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.124-125
    • /
    • 2012
  • Korea institute of materials science (KIMS) use a linear deposition source called as a closed drift linear plasma source (CDLPS) as well as dual magnetron sputtering (DMS) to deposit SiOxCyHz films in $HMDSO/O_2$ plasma. The CDLPS generates linear plasma using closed drifting electrons and can reduce device degradations due to energetic ion bombardments on organic devices such as organic photovoltaic and organic light emission diode by controlling an ion energy. The deposited films are investigated by Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Optical emission spectroscopy (OES) is used to measure relative radical populations of dissociation and recombination products such as H, CH, and CO in plasma. And SiOx film is applied to a barrier film on organic photovoltaic devices.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF