• Title/Summary/Keyword: linear polarization

Search Result 318, Processing Time 0.024 seconds

Package-type polarization switching antenna using silicon RF MEMS SPDT switches (실리콘 RF MEMS SPDT 스위치를 이용한 패키지 형태의 편파 스위칭 안테나)

  • Hyeon, Ik-Jae;Chung, Jin-Woo;Lim, Sung-Joon;Kim, Jong-Man;Baek, Chang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1511_1512
    • /
    • 2009
  • This paper presents a polarization switching antenna integrated with silicon RF MEMS SPDT switches in the form of a package. A low-loss quartz substrate made of SoQ (silicon-on-quartz) bonding is used as a dielectric material of the patch antenna, as well as a packaging lid substrate of RF MEMS switches. The packaging/antenna substrate is bonded with the bottom substrate including feeding lines and RF MEMS switches by BCB adhesive bonding, and RF energy is transmitted from signal lines to antenna by slot coupling. Through this approach, fabrication complexity and degradation of RF performances of the antenna due to the parasitic effects, which are all caused from the packaging methods, can be reduced. This structure is expected to be used as a platform for reconfigurable antennas with RF MEMS tunable components. A linear polarization switching antenna operating at 19 GHz is manufactured based on the proposed method, and the fabrication process is carefully described. The s-parameters of the fabricated antenna at each state are measured to evaluate the antenna performance.

  • PDF

Design of Dual-band Ortho-mode Transducer for Ka-band VSATs (Ka 대역 VSAT용 이중대역 직교모드변환기 설계)

  • Lee, Hongyeol;Uhm, Manseok;Yun, Sohyeun;Yom, Inbok;Kim, Hyunsoo;Park, Jeongwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • In this paper, we present design and test results of a Ka-band dual-band ortho-mode transducer (OMT) for use in a feed assembly for the very small aperture terminals (VSATs). The designed ortho-mode transducer have wideband characteristics to separate the signals that have two orthogonal linear polarizations operating at 20GHz of receive frequency band and at 30GHz of transmit frequency band. In addition, in order to reduce the volume of the feed assebly, a Boifot based ortho-mode transducer has been designed with a dual-band. Experimental results for the design verification, the return loss in the receive band and in the transmit band for the horizontal polarization showed over 20dB and 21dB, respectively, and for the vertical polarization showed over 20dB and 24dB, respectively. The port isolation for the horizontal polarization and the vertical polarization showed over 43dB and 52dB, respectively, in the receive band and in the vertical band.

Design of a Antenna with Enhanced Isolation for US-PCS Indoor Repeater (격리도가 향상된 US-PCS 대역 댁내용 중계기 안테나 설계)

  • Ahn Jung-Sun;Lee Jin-Sung;Jung Byung-Woon;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.9-18
    • /
    • 2005
  • This paper presents an antenna for US-PCS band indoor repeaters with enhancement of isolation. In common repeaters require an enough isolation to reduce the interferences between transmitted and received signals. Thus, it is investigated to improve front-to-back ratio of IBD(Integrated Balun Dipole) antenna which has a good linear polarization with a cavity or multi-cavity by using polarization diversity and aperture matching method. From the simulated and measured results, the antenna realized by using polarization diversity and aperture matching method has a VSWR below 1.5, gain over 8 dBi and enhanced isolation of 15$\~$24 dB in US-PCS band.

Monitoring of Gamma-ray Bright AGN : The Multi-Frequency Polarization of the Flaring Blazar 3C 279

  • Kang, Sincheol;Lee, Sang-Sung;Byun, Do-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2016
  • We present results of long-term multi-wavelength polarization observations of the powerful blazar 3C 279 after its ${\gamma}$-ray flare on 2013 December 20. We followed up this flare by means of single-dish polarization observations with two 21-m telescopes of the Korean VLBI Network, carried out weekly from 2013 December 25 to January 11, and at 22, 43, and 86 GHz, simultaneously. These observations were part of the Monitoring Of GAmma-ray Bright AGNs (MOGABA) program. We Measured 3C 279 total flux densities at 22, 43, and 86 GHz, showing a mild variability of a factor of ${\leq}50%$ over the period of our observations. The spectral index ranged from -0.13 to -0.36 at between 22 and 86 GHz. The degree of linear polarization was in the range of 6 ~ 12 %, and slightly decreased with time at all frequencies. We found Faraday rotation measures (RM) of -300 to $-1200rad\;m^{-2}$ between 22 and 43 GHz, and -800 to $-5100rad\;m^{-2}$ between 43 and 86 GHz. The RM values follow a power law ${\mid}RM{\mid}{\propto}{\nu}^{\alpha}$, with a mean ${\alpha}$ of 2.2, implying that the polarized emission at these frequencies travels through a Faraday screen in or near the jet. We conclude that the regions emitting polarized radio emission may be different from the region responsible for the 2013 December ${\gamma}$-ray flare, and that these regions are maintained by the dominant magnetic field perpendicular to the direction of the radio jet at milliarcsecond scales.

  • PDF

Consideration about phase error of the MTI system (변형 삼각간섭계에서의 위상오차에 관한 고찰)

  • Kim, Soo-Gil;Ko, Myung-Sook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.169-171
    • /
    • 2007
  • We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer(MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we simulated such potential phase errors in the optimized MTI.

  • PDF

Analysis of Optical Transfer Function and Phase Error of the Modified Triangular Interferometer

  • Kim, Soo-Gil;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2007
  • We synthesize and analyze the optical transfer function(OTF) of the modified triangular interferometer(MTI) using two-pupil synthesis method and we present the optimal MTI, which can obtain any bipolar function by combining a wave plate and a linear polarizer. Also, we analyze its potential phase error sources caused by polarization components.

Optimization of Modified Triangular Interferometer (MNT 시스템에서의 편광소자에 의한 위상오차분석)

  • Kim, Soo-Gil;Ko, Myung-Sook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.117-119
    • /
    • 2007
  • We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer(MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we analyzed such potential phase errors in the optimized MTI.

  • PDF

Electrical and Rheological Properties of Chitosan Malonate Suspension

  • Choi, Ung-su
    • KSTLE International Journal
    • /
    • v.4 no.1
    • /
    • pp.14-17
    • /
    • 2003
  • The electrical and rheological properties of a chitosan malonate suspension in silicone oil was investigated by varying the electric fields, volume fractions of particles, and shear rates, respectively, The chitosan malonate susepnsion showed a typical electrorheological (ER) response caused by the polarizability of an amide polar group and shear yield stress due to the formation of multiple chains upon application of an electric field. The shear stress fur the suspension exhibited a linear dependence on the volume fraction and an electric field power of 1.88. On the basis of the experimental results, the newly synthesized chitosan malonate suspension was found to be an anhydrous ER fluid.

Phase Error Analysis in Polarization Phase-shifting Technique using a Wollaston Prsim and Wave Plates

  • Kim Soo-Gil
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.145-150
    • /
    • 2005
  • The method to obtain four speckle patterns with relative phase shift of $\pi$/2 by passive devices such as two waveplates and a linear polarizer, and to calculate the phase at each point of the speckle pattern in shearography with a Wollaston prism is described. In this paper, we analyze its potential error sources caused by wave plates.

Stabilization of Fiber-optic Current Sensor Using a Faraday Rotator Mirror (Faraday 반사경을 이용한 광섬유형 전류센서의 안정화)

  • 김기혁;송민호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.72-76
    • /
    • 2003
  • We developed a polarimetric fiber-optic current sensor using a length of twisted fiber and a Faraday rotator mirror which was used to suppress the linear birefringence effect. A gold coated mirror was also used as the sensor coil reflector, and the results were compared with the case of FRM. From the experimental results, it is clear that the FRM greatly enhances the stability of the fiber optic current sensor output..