Design and Experiment of Ku_band Linear Active Phased Array Antenna System (Ku 대역 선형 능동 위상 배열 안테나 시스템 설계 및 실험)

  • Ryu Sung-Wook;Eom Soon-Young;Yun Jae-Hoon;Jeon Soon-Ick;Kim Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.694-705
    • /
    • 2006
  • In this paper, the linear active phased array antenna system operated in Ku DBS band was designed and experimented. The antenna system was composed of sixteen radiating active channels and Wilkinson power combiners with 16-channel inputs, a stabilizing DC bias and phase control board. Electrical beams of the antenna system can be formed by controling the phase-states of 3-bit digital phase shifter inside each active channel by virtue of the phase control board. The amplitude and phase deviations measured between active channels were less than ${\pm}0.8dB$ and ${\pm}15^{\circ}$, respectively, and the noise figure of each active channel was measured less than 1.2 dB in the operating band. The measured performances of the overall antenna system showed the antenna gain of more than 23.07 dBi and the sidelobe level of less than -11.17 dBc, and the bore-sight cross-polarization level of less than -12.75 dBc in the operating band. Also, by phase-controlling active channels, the beam scan patterns at $10^{\circ},\;20^{\circ},\;30^{\circ}$ were measured, and the losses caused by the corresponding beam scanning were 1.1 dB, 2.5 dB and 3.6 dB from the measurements, respectively.

Flux Model of One-shaft Rotary Disc UF Module for the Separation of Oil Emulsion (1축 회전판형 UF 모듈의 투과모델 및 Oil Emulsion 분리 특성)

  • 김제우;노수홍
    • Membrane Journal
    • /
    • v.6 no.2
    • /
    • pp.86-95
    • /
    • 1996
  • Rotary disc ultrafiltration module(RDM) was developed for the separation of oil e$$\mu$sions. This module was devised to reduce the gel polarization phenomenon by decoupling the operation pressure and the surface velocity of solution in ultrafiltration(UF) processes. The rotary disc membrane consists of 3mm-thick ABS plate covered with UF membrane (UOP, U.S.A.). When the angular velocity($\omega$) was increased, the pure water flux was slightly decreased due to pressure drop caused by centrifugal force and slip flow at the surface of membrane. The pressure drop was proportional to the square of linear velocity(${\omega}r$). When the angular velocity was changed from 52.36rad/s to 2.62rad/s, the flux decline for 5% cutting oil in one-shaft RDM at $25^{\circ}C$ and 0.1MPa was 30.16%. In the lower concentrations, angular velocity tends to give less effect on the flux. Flux(J; $kg/m^{2} \cdot s$) in a rotating disc module is mainly a function of the bulk concentration($C_{B}$; %), the linear velocity(${\omega}r$; m/s) and the effective transmembrane pressure($\Delta P_{T}$ ; Pa). Using a modified resistance-in-series model, the flux data of cutting oil experiments were fitted to give the following equation.

  • PDF

Task-Biased Technological Change, Occupational Structural Change, and Wage Premium in Local Labor Market Areas, Korea (업무편향적 기술변화에 따른 지역노동시장에서의 일자리 구조 변화와 임금 프리미엄 영향요인)

  • Changhyun Song;Up Lim
    • Journal of the Korean Regional Science Association
    • /
    • v.39 no.4
    • /
    • pp.33-51
    • /
    • 2023
  • This study aims to investigate the changes in the employment structure of occupational groups by job characteristics and analyze the factors influencing wage premiums in local labor markets from 2010 to 2020. This study's analysis involves three primary steps. First, the occupational characteristics data from the Korea Network for Occupations and Workers are subjected to an exploratory factor analysis, and then a non-routine task intensity index is calculated by each occupations. Then, we conduct an exploratory analysis of changes in the distribution of employment by occupation from 2010 to 2020 by combining data from the Population Census with data from the Korean Labor and Income Panel Study to construct individual-level and regional-level data. Thirdly, we employ a hierarchical linear model to examine the individual-level and regional-level factors influencing wage premiums. Since 2010, the proportion of employment in occupations requiring non-routine task has continued to rise and now dominates the metropolitan labor market. Moreover, agglomeration effects resulting from urbanization produce a substantial wage premium for wage workers in occupations requiring non-routine tasks. This study seeks to provide policy implications to mitigate inequality and polarization in local labor markets by empirically analyzing the transition of occupational structure and wage inequality in relation to the local labor market context.

Estimation of Soil Moisture Using Sentinel-1 SAR Images and Multiple Linear Regression Model Considering Antecedent Precipitations (선행 강우를 고려한 Sentinel-1 SAR 위성영상과 다중선형회귀모형을 활용한 토양수분 산정)

  • Chung, Jeehun;Son, Moobeen;Lee, Yonggwan;Kim, Seongjoon
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.515-530
    • /
    • 2021
  • This study is to estimate soil moisture (SM) using Sentinel-1A/B C-band SAR (synthetic aperture radar) images and Multiple Linear Regression Model(MLRM) in the Yongdam-Dam watershed of South Korea. Both the Sentinel-1A and -1B images (6 days interval and 10 m resolution) were collected for 5 years from 2015 to 2019. The geometric, radiometric, and noise corrections were performed using the SNAP (SentiNel Application Platform) software and converted to backscattering coefficient of VV and VH polarization. The in-situ SM data measured at 6 locations using TDR were used to validate the estimated SM results. The 5 days antecedent precipitation data were also collected to overcome the estimation difficulty for the vegetated area not reaching the ground. The MLRM modeling was performed using yearly data and seasonal data set, and correlation analysis was performed according to the number of the independent variable. The estimated SM was verified with observed SM using the coefficient of determination (R2) and the root mean square error (RMSE). As a result of SM modeling using only BSC in the grass area, R2 was 0.13 and RMSE was 4.83%. When 5 days of antecedent precipitation data was used, R2 was 0.37 and RMSE was 4.11%. With the use of dry days and seasonal regression equation to reflect the decrease pattern and seasonal variability of SM, the correlation increased significantly with R2 of 0.69 and RMSE of 2.88%.

Study for the Size Reduction of Microstrip Patch Antenna using Corrugation (주름 구조를 이용한 마이크로스트립 패치 안테나의 소형화에 대한 연구)

  • 송무하;우종명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.192-201
    • /
    • 2003
  • In this paper, to reduce the size of patch, three types of 3-dimensional patch antennas which are one-directionally-corrugaged type, rectangular ring-likely corrugated type, and lattice-likely corrugated type rectangular microstrip patch antennas(MPA) are designed and fabricated at the 1.575 GHz. As the result, one-directionally corrugated rectangular MPA is reduced in the resonant length of patch by 21.4% than that of general plane MPA. -10 dB bandwidth(B.W) is 62 MHz(3.9 %) and this is broader than that(39 MHz, 2.5 %) of plane MPA by 23 MHz(1.5 %). The gain is 5.8 dBd and this is reduced by 0.9 dB than that(6.7 dBd) of plane MPA. Half power beamwidth(HPBW) is broadened by 18$^{\circ}$ than that of plane MPA in the E-plane and this is due to the reduced length of patch. For rectangular ring-likely corrugated retangular MPA, the patch size is miniaturized by 21.6 % than that of plane MPA. For lattice-likely corrugated rectangular MPA, in the linear polarization, the size of patch is miniaturized by 43.3 % than that of plane MPA. -10 dB B.W is 70 MHz(4.4 %) and this is broadened than that of plane MPA by 31 MHz(2 %). Gain is 2.2 dBd and this is smaller than that of plane MPA by 4.5 dB. HPBW is increased in both E-plane and H-plane by 22$^{\circ}$ and 13$^{\circ}$, respectively. For circular polarization, the size of patch is reduced by 41 % than that by 41 %. The axial ratio(AR) is 0.8 dB at the 1.575 GHz and the axial ratio bandwidth(ARBW) within 2 dB is 20 MHz(1.27 %) and this is increased by 10 MHz(0.63 %) than that 10 MHz(0.63 %) of plane MPA. From all the results above, it is conformed that the proposed antenna has merit in size reduction of patch and in the input impedance B.W, and is more profitable in many application than the general plane type MPA.

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Corrosion Resistance of Blended Concrete and Its Application to Crack Healing (혼합 콘크리트의 부식 저항성과 균열 치유 적용)

  • Lee, Chang-Hong;Kim, Tae-Sang;Song, Ha-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.689-696
    • /
    • 2009
  • In this study, electro-deposition method was applied to heal cracks in various blended concrete. The performance of the method was indirectly monitored by measuring impressed voltage, electrolyte, galvanic current monitoring, linear polarization resistance, and directly by image analysis of the cracks. The indirect and direct monitoring values are compared to develop guidelines for relating the indirect measures to actual crack healing. As a result, It was found that impressed voltage was convergence to 2.9V after 20000 minutes. From the galvanic current test results of artificial crack healing, the corrosion resistance showed that the order of 0.4 $>$ 0.6 $>$ 0.5 water to cement ratio. Furthermore, in view of binder, the corrosion resistance order was calculated OPC $>$ 60%GGBS $>$ 10%SF $>$ 30%PFA. Finally, It was found that 76.47% of healed crack surface calculated from the artificial crack healing technique using electrochemical deposition method.

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.

A Study on a Planar Array Antenna Design with a Flat-Topped Radiation Pattern (구형 방사 패턴을 갖는 평면 배열 안테나 설계에 대한 연구)

  • Eom Soon-Young;Pyo Cheol-Sig;Jeon Soon-Ick;Kim Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.896-905
    • /
    • 2004
  • In this paper, the design, fabrication and experiment on a planar array antenna with a flat-topped radiation pattern for a mobile base station antenna were described. The current distribution of an antenna aperture, which is easily realizable in a feeding network compared with the conventional one of sin(x)/x was optimized for shaping a desired flat-topped radiation pattern. The planar array antenna designed in this paper has a rectangular lattice and is composed of array elements of 16${\times}$8. Each radiating element, which is a microstrip element fed coaxially, has a linear vertical polarization and the feed network which use a Wilkinson power divider and a 180$^{\circ}$ ring hybrid coupler as a base element is designed. The flat-topped radiation pattern with 90$^{\circ}$ is shaped by 16 array elements with the element spacing of 0.55 λ$_{ο}$ in the azimuth plane, and the normal radiation pattern with 10$^{\circ}$ is shaped by 8 array elements with the element spacing of 0.65 λ$_{ο}$ in the elevation plane. Also, the planar array antenna is symmetrically divided into four parts. It consists of one hundred-twenty-eight radiating elements, thirty-two 1-4 column dividers, low 1-8 row dividers and one 1-4 input power divider. In order to verify electrical performances of the planar way antenna proposed in this paper, the experimental breadboard operated in tile band of 1.92~2.17 GHz(IMT2000 band) was fabricated, and its experimental results were a good agreement with simulation ones.

Material Characteristic of POFA Concrete and Its Application to Corrosion Resistance Evaluation (POFA 콘크리트의 재료특성 및 부식 저항성 평가로의 적용)

  • Lee, Chang-Hong;Song, Ha-Won;Ann, Ki-Yong;Ismail, Mohamed Abdel
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.565-572
    • /
    • 2009
  • In this study, corrosion resistance of palm oil fuel ash (POFA) concrete as a blended concrete is evaluated by using electrochemical technique. The POFA is an industrial byproduct obtained from fuel ash after extracting palm oil from palm-tree. In order to obtain basic material characteristics of the POFA concrete, tests on compressive strength, slump, weight loss, bleeding and expansion ratio were carried out the early-aged POFA concrete. On the other hand, durability characteristics, both chloride penetration and carbonation depth test, were also conducted. Finally, corrosion resistance were evaluated by applying electro-chemical artificial crack healing technique, and the tests on the impressed voltage characteristic, galvanic current and linear polarization resistance. From the experimental results, it was found that long-term strength, bleeding, lower slump ratio, expansion ratio, chloride penetration, carbonation and corrosion resistance were improved by using the POFA due to activated pozzolanic reaction. It can be also mentioned that POFA concrete has a potential to be used as a cementitious binder for green-recycling resources.