• Title/Summary/Keyword: linear

Search Result 36,004, Processing Time 0.063 seconds

Effect of Calcium Chloride($CaCl_2$) on Chlorophyll Fluorescence Image and Photosynthetic Apparatus in the Leaves of Prunus sargentii (염화칼슘 처리가 산벚나무 엽의 엽록소형광반응과 광합성기구에 미치는 영향)

  • Sung, Joo-Han;Je, Sun-Mi;Kim, Sun-Hee;Kim, Young-Kul
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.6
    • /
    • pp.922-928
    • /
    • 2010
  • There is a little information on the effect of calcium cloride ($CaCl_2$) which is used as deicing salt in Korea on the physiological responses of the street trees. Prunus sargentii is one of the most widespread tree species of street vegetation in Korea. In this study, the effect of $CaCl_2$ on photosynthetic apparatus such as chlorophyll fluorescence image and light response curve of P. sargentii in relation to their leaf and root collar growth responses were investigated. To study the effect of $CaCl_2$ treatment in the early spring, we irrigated twice in rhizosphere of P. sargentii (3-year-old) planted plastic pots with solution of 0.5%, 1.0%, 3.0% $CaCl_2$ concentration before leaf expansion. Results after treatments, total chlorophyll contents and the chlorophyll a/b, photosynthetic rate, quantum yield, dark respiration decreased with increasing $CaCl_2$ concentration. On the contrary, light compensation point increased with increasing $CaCl_2$ concentration. Through the linear regressions of correlation of photosynthetic rate with photosynthetic parameters (quantum yield, dark respiration and light compensation point), we found a significant relationship (p<0.05) between photosynthetic rate and quantum yield and light compensation point except dark respiration. Calcium cloride ($CaCl_2$) induced inhibition of photochemical efficiency ($F_v/F_M$) and non-photochemical quenching (NPQ) were found in treatments of $CaCl_2$, and these reduction rates between control and CaCl2 treatments were drastically showed at 80 days. We suggest that physiological activities are limited from treatment of $CaCl_2$. These reductions of photosynthetic apparatus ability caused eventually the reduction of leaf and diameter at root collar growth.

Optimization of the Truss Structures Using Member Stress Approximate method (응력근사해법(應力近似解法)을 이용한 평면(平面)트러스구조물(構造物)의 형상최적화(形狀最適化)에 관한 연구(研究))

  • Lee, Gyu Won;You, Hee Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-84
    • /
    • 1993
  • In this research, configuration design optimization of plane truss structure has been tested by using decomposition technique. In the first level, the problem of transferring the nonlinear programming problem to linear programming problem has been effectively solved and the number of the structural analysis necessary for doing the sensitivity analysis can be decreased by developing stress constraint into member stress approximation according to the design space approach which has been proved to be efficient to the sensitivity analysis. And the weight function has been adopted as cost function in order to minimize structures. For the design constraint, allowable stress, buckling stress, displacement constraint under multi-condition and upper and lower constraints of the design variable are considered. In the second level, the nodal point coordinates of the truss structure are used as coordinating variable and the objective function has been taken as the weight function. By treating the nodal point coordinates as design variable, unconstrained optimal design problems are easy to solve. The decomposition method which optimize the section areas in the first level and optimize configuration variables in the second level was applied to the plane truss structures. The numerical comparisons with results which are obtained from numerical test for several truss structures with various shapes and any design criteria show that convergence rate is very fast regardless of constraint types and configuration of truss structures. And the optimal configuration of the truss structures obtained in this study is almost the identical one from other results. The total weight couldbe decreased by 5.4% - 15.4% when optimal configuration was accomplished, though there is some difference.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Normal blood pressure values and percentile curves measured by oscillometric method in children under 6 years of age (진동식 자동 혈압계로 측정한 6세 이하 아동의 정상 혈압치와 백분위수 곡선)

  • Sohn, Jin A;Lee, Hee Sook;Lim, Kyoung Aha;Yoon, So Young;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Lee, Soon Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.998-1006
    • /
    • 2008
  • Purpose : Hypertension is defined as average systolic blood pressure and/or diastolic blood pressure that is ${\geq}95^{th}$ percentile for gender, age, and height on ${\geq}three$ occasions. Knowing that blood pressure values increase in children as they grow older, the purposes of this study were to measure blood pressure by an oscillometric device and to determine normal values and percentile curves for children. Methods : Systolic and diastolic blood pressures were measured twice with an oscillometric device in 3,545 boys and 3,145 girls under six years of age, in Seoul. Using this data, we determined average blood pressure values and percentile curves based on gender and age; we subdivided these values into blood pressures of $50^{th}$, $90^{th}$, $95^{th}$, and $99^{th}$ percentiles, by percentile of height. The regression coefficients and standard deviations of the systolic and diastolic blood pressure values were obtained from linear regression models. Results : Older boys and girls had higher systolic and diastolic blood pressure values. Older boys and girls in the same percentile of height for age had higher systolic and diastolic blood pressure values. Taller boys and girls within the same age group had higher systolic and diastolic blood pressure values. Conclusion : Blood pressure standards based on gender, age, and height were obtained via an oscillometric method. Llimitation of this study is that the study population was not from the whole country, but exclusively from Seoul. Nonetheless, the data from this study will be helpful in diagnosing and managing hypertension in Korean children.

A Preliminary Study for Nonlinear Dynamic Analysis of EEG in Patients with Dementia of Alzheimer's Type Using Lyapunov Exponent (리아프노프 지수를 이용한 알쯔하이머형 치매 환자 뇌파의 비선형 역동 분석을 위한 예비연구)

  • Chae, Jeong-Ho;Kim, Dai-Jin;Choi, Sung-Bin;Bahk, Won-Myong;Lee, Chung Tai;Kim, Kwang-Soo;Jeong, Jaeseung;Kim, Soo-Yong
    • Korean Journal of Biological Psychiatry
    • /
    • v.5 no.1
    • /
    • pp.95-101
    • /
    • 1998
  • The changes of electroencephalogram(EEG) in patients with dementia of Alzheimer's type are most commonly studied by analyzing power or magnitude in traditionally defined frequency bands. However because of the absence of an identified metric which quantifies the complex amount of information, there are many limitations in using such a linear method. According to the chaos theory, irregular signals of EEG can be also resulted from low dimensional deterministic chaos. Chaotic nonlinear dynamics in the EEG can be studied by calculating the largest Lyapunov exponent($L_1$). The authors have analyzed EEG epochs from three patients with dementia of Alzheimer's type and three matched control subjects. The largest $L_1$ is calculated from EEG epochs consisting of 16,384 data points per channel in 15 channels. The results showed that patients with dementia of Alzheimer's type had significantly lower $L_1$ than non-demented controls on 8 channels. Topographic analysis showed that the $L_1$ were significantly lower in patients with Alzheimer's disease on all the frontal, temporal, central, and occipital head regions. These results show that brains of patients with dementia of Alzheimer's type have a decreased chaotic quality of electrophysiological behavior. We conclude that the nonlinear analysis such as calculating the $L_1$ can be a promising tool for detecting relative changes in the complexity of brain dynamics.

  • PDF

Effects of X-ray Irradiation on the Survival Rate and Weight of the Rhinoceros Beetle Larvae (X선 이 장수풍뎅이 유충의 체중과 생존율에 미치는 영향)

  • Lee, Won-Jeong;Lim, Dong-Hwan;Park, Jeong-Soon;Sim, Yeung-Eun;Jeong, Yoo-Jin;Kim, Jeong Ho;Yoo, Se Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.271-277
    • /
    • 2020
  • The Purpose of this study was to examine the survival rate and weight of rhinoceros beetle larvae by irradiating X-rays which are most commonly used in diagnosing and treating for diseases. Subjectts and Methods: In early April 2019, the rhinoceros beetle larvae 41 were classified into two groups as control group (11 larvae) and irradiated group (10 Gy, 20 Gy, 30 Gy, each 10 larvae). The irradiated group was exposed by 6 MV X-ray using linear accelerators (Clinac IS, VERIAN, USA) at the University Hospital in Daejeon (Source-surface distance 96 cm, field size 18 × 10 cm, dose rate 600 MU/min), after environmental adaptation for 3 days (temperature 20.6℃, humidity 64.3%). The survival rate and weight were measured weekly after irradiating X-ray. All statistical analyses were performed using the SPSS ver. 22.0 (Chicago, IL, USA). The weight was analysed by Independent T-test, by cross-sectional analysis for survival rates between control and X-ray irradiated groups. Also, the correlation between dose and weight was analyzed by Spearman test. In 3-week after irradiating X-ray, weight was significant difference between control group and irradiated group (10 Gy or 20 Gy, p < 0.05; and 30 Gy, p < 0.01) with increasing weight in all experimental groups. In 14-week, weight was increased in the control group, but decreased in irradiated group. weight was significant difference between control group and irradiated group. The survival rate in 3-week was decreased rapidly in all experimental group except 10 Gy, to 4-week in irradiated group. The control group had no change in survival rate 54.5% from 3-week to 14-week. From the 3-week, it showed lower survival rate with increasing radiation dose in irradiated group. In 19-week, survival rate of control group and 10 Gy was 45.4% and 30.0% respectively, all died in 20 Gy and 30 Gy. Weight was significantly negative correlated with radiation dose as longer time after irradiating X-ray. The weight and survival rate of rhino beetle larvae is affected by irradiating X-rays, weight and survival rate decreased more in higher dose.