• Title/Summary/Keyword: line sources

Search Result 621, Processing Time 0.038 seconds

An Adaptive Filtering Technique for Vibration Reduction of a Rotational LOS Control System and Frequency Noise Reduction of an Imaging System (적응형 필터링 기법을 이용한 회전형 시선제어시스템의 진동 저감 및 영상 주파수노이즈 저감 기법)

  • Kim, Byeong-Hak;Kim, Min-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.10
    • /
    • pp.1014-1022
    • /
    • 2014
  • In mechatronic systems using electric signals to drive control systems, driving signals including the frequency band of the unwanted signals, such as resonant frequencies and noise frequencies, can affect the accuracy of the controlled system and can cause serious damage to the system due to the resonance phenomenon of the mechatronic system. An LOS (Line of Sight) control unit is used to automatically rotate the gimbal system with a video imaging system generally mounted on modern aerial vehicles. However, it still suffers from natural frequency variation problems due to variations of operational temperature. To prevent degradation in performance, this paper proposes an adaptive filtering technique based on real-time noise analysis and adaptive notch-filtering for LOS control systems, and verifies how our proposed method maintains the LOS stabilization performance. Additionally, this filtering technique can be applied to the image noise filtering of the video imaging system. It is designed to reduce image noises generated by switching circuits or power sources. The details of design procedures of the proposed filtering technique and the experiments for the performance verification are described in this paper.

A Study on Multistage Mean Filter for Image Restoration (영상복원을 위한 다중 평균 필터에 관한 연구)

  • Long, Xu;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.765-767
    • /
    • 2013
  • Modern societies need image processing technology as mobile phones, computers and multimedia etc. are supplied, and image signal processing is now applied in many fields. However, images are damaged by impulse noise from various sources; to restore the damaged images from impulse noise standard median filter has been used as a typical method, but it makes errors at edge area lowering image quality. Therefore, in this paper average filter algorithm, in which mask is processed with multiple partition to remove impulse noise, is proposed. Simulation showed that the proposed method is superior in noise removal property to the existing ones.

  • PDF

Design and Implementation of Video Encoder with Error less than $\pm$1 LSB ($\pm$1LSB 이하의 오차를 가지는 복합 영상 부호화기의 설계 및 구현)

  • 김주현;강봉순
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1147-1152
    • /
    • 2004
  • This paper presents the design of a multi-standard NTSC/PAL video encoder. The encoder converts International Telecommunication Union-Recommendation (ITU-R) BT.601 4:2:2, ITU-R BT.656 or RGB inputs from various video sources into National Television Standards Committee (NTSC) or phase-alternate line (PAL) TV signals in both S-video and composite video baseband signals (CVBS). The encoder adopts multiplier-free structures to reduce hardware complexity. The hardware bit width of programmable digital filters for luminance and chrominance signals, along with other operating blocks, are carefully determined to produce high-quality digital video signals of 1 least significant bit (LSB) error or less. The proposed encode. is experimentally demonstrated by using the Altera APEX20K600EBC652-3 device.

Correction of Overcurrent Protective Relay on Distribution Feeders Considering the Power Output of Wind Farm Interconnected with Utility Networks (계통 연계 풍력발전단지의 출력 조건을 고려한 배전선 과전류 계전기 정정)

  • Kim, J.W.;Jang, S.I.;Kim, K.H.;Yoo, N.S.;Park, H.J.;Song, D.S.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.342-344
    • /
    • 2003
  • This paper describes the correction of overcurrent protective relaying set value in distribution networks interconnected with wind farm by dedicated line. The wind farm composed of wind turbine generators is one of the great energy sources; however, it would be also highly possible that the current in the point of common coupling is influenced by the output power of wind farm. So, the overcurrent relay applied in distribution feeders might generate trip signal for normal operation. In order to prevent the mal-operation of overcurrent relay, it is necessary to correct the relay's setting value according to the output power of end farm. This paper presents the influence of wind farm on the overcurrent relaying set value in distribution feeders for cases of fault as well as normal operation and proposes the basic strategy for correction of overcurrent relaying set value.

  • PDF

Impact of Different Boundary Conditions in Generating g-function on the Sizing of Ground Heat Exchangers (경계 조건에 따른 지열 응답 함수의 차이가 수직형 지열 교환기 길이 산정에 미치는 영향)

  • Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.263-268
    • /
    • 2014
  • Eskilson's g-function, a well-known geothermal heat response factor, is widely used for sizing of the ground heat exchangers. Unlike the Eskilson's original model that uses common temperature boundaries for all boreholes and along the borehole height, an analytical-solution-based g-function uses a uniform heat transfer rate over the height with variable heat transfer rates for respective boreholes. To evaluate the impact of such a boundary difference on g-function and the design length, a simple case study was carried out on the cooling-dominant commercial buildings. The results show that the design lengths given by the boundary of uniform heat transfer rates are longer than those given by Eskilson's boundary for all cases tested. The difference in length is more important when the bore field is composed of more boreholes with shorter length of each borehole.

Minimizing Zinc Consumption In Hot-Dip Galvanizing Lines

  • Bright, Mark;Ellis, Suzanne
    • Corrosion Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.43-46
    • /
    • 2011
  • Zinc consumption in a continuous galvanizing line is one of the highest operating cost items in the facility and minimizing zinc waste is a key economic objective for any operation. One of the primary sources of excessive loss of zinc is through the formation of top dross and skimmings in the coating pot. It has been reported that the top skimmings, manually removed from the bath, typically consist of more than 80% metallic zinc with the remainder being entrained dross particles ($Fe_2Al_5$) along with some oxides. Depending on the drossing practices and bath management, the composition of the removed top skimmings may contain up to 2 wt% aluminum and 1 wt% iron. On-going research efforts have been aimed at in-house recovery of the metallic zinc from the discarded top skimmings prior to selling to zinc recycling brokers. However, attempting to recover the zinc entrapped in the skimmings is difficult due to the complex nature of the intermetallic dross particles and the quality and volume of the recycled zinc is highly susceptible to fluctuations in processing parameters. As such, an efficient method to extract metallic zinc from top skimmings has been optimized through the use of a specialized thermo-mechanical process enabling a continuous galvanizing facility to conserve zinc usage on-site. Also, through this work, it has been identified that filtration of discrete dross particles has been proven effective at maintaining the cleanliness of the zinc. Future efforts may progress towards expanded utilization of filters in continuous galvanizing.

A Study on the Business Models and Competitive Strategies of the Real Estate Portals in Korea (국내 부동산포탈 사이트의 비즈니스 모델과 경쟁전략에 관한 연구)

  • Joo, Jeong-Do;Shim, Sang-Ryul;Moon, Hee-Cheol
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.4
    • /
    • pp.41-56
    • /
    • 2006
  • The real estate portal has grown into a successful e-Business model that is combined on and off line. Although IT technologies have shown rapid growth, the real estate portals have failed to satisfy the expectations of the Internet users. Based on Michael Porter's competitive forces framework, this study proposes five competitive strategies for continuing growth of the real estate portals. First, to strengthen bargaining power against supplier, buyer and potential new entrants, the real estate portals need to construct a basic network that is cost efficient and maintains real estate goods and makes profits by collaborative deals. Second, strengthen brand value and endeavor to escape from dependency on the Internet portals. Third, develop services to consider changed circumstances and give a lot of sources to make profit to real estate agencies. Fourth, concentrate on marketing to draw in the Internet users and adapt strategies that have been successful in other fields. Finally, real estate fields can seek out ideas for developing new business models from other successful e-Business models and should benchmark them to reduce expenses to a minimum and increase benefits to a maximum.

  • PDF

Vulnerability Assessment of a Large Sized Power System Using Neural Network Considering Various Feature Extraction Methods

  • Haidar, Ahmed M. A;Mohamed, Azah;Hussian, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.167-176
    • /
    • 2008
  • Vulnerability assessment of power systems is important so as to determine their ability to continue to provide service in case of any unforeseen catastrophic contingency such as power system component failures, communication system failures, human operator error, and natural calamity. An approach towards the development of on-line power system vulnerability assessment is by means of using an artificial neural network(ANN), which is being used successfully in many areas of power systems because of its ability to handle the fusion of multiple sources of data and information. An important consideration when applying ANN in power system vulnerability assessment is the proper selection and dimension reduction of training features. This paper aims to investigate the effect of using various feature extraction methods on the performance of ANN as well as to evaluate and compare the efficiency of the proposed feature extraction method named as neural network weight extraction. For assessing vulnerability of power systems, a vulnerability index based on power system loss is used and considered as the ANN output. To illustrate the effectiveness of ANN considering various feature extraction methods for vulnerability assessment on a large sized power system, it is verified on the IEEE 300-bus test system.

Hybrid BFPSO Approach for Effective Tuning of PID Controller for Load Frequency Control Application in an Interconnected Power System

  • Anbarasi, S.;Muralidharan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1027-1037
    • /
    • 2017
  • Penetration of renewable energy sources makes the modern interconnected power systems to have more intelligence and flexibility in the control. Hence, it is essential to maintain the system frequency and tie-line power exchange at nominal values using Load Frequency Control (LFC) for efficient, economic and reliable operation of power systems. In this paper, intelligent tuning of the Proportional Integral Derivative (PID) controller for LFC in an interconnected power system is considered as a main objective. The chosen problem is formulated as an optimization problem and the optimal gain parameters of PID controllers are computed with three innovative swarm intelligent algorithms named Particle Swarm Optimization (PSO), Bacterial Foraging Optimization Algorithm (BFOA) and hybrid Bacterial Foraging Particle Swarm Optimization (BFPSO) and a comparative study is made between them. A new objective function designed with necessary time domain specifications using weighted sum approach is also offered in this report and compared with conventional objective functions. All the simulation results clearly reveal that, the hybrid BFPSO tuned PID controller with proposed objective function has better control performances over other optimization methodologies.

Contingency Analysis for Small Signal Stability of Power Systems (전력계통의 미소신호안정도 상정사고 해석)

  • 심관식;김용구;문채주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.127-137
    • /
    • 2003
  • Contingency analysis is one of the most important tasks encountered by planning and operation of lafe scale power systems. This paper describes a new contingency analysis methods for small signal security assessment based on the eigen-sensitivity/perturbation of the electromechanical oscillation modes. The eigen-sensitivity/perturbation with respect to line suceptances and controller parameters can he used to find possible sources of the system instability, and to select contingency for small signal stability. Also, the contingency selection to identify critical generators for MW changes can be obtained by computing the relative movement of the system oscillation modes. The proposed algorithm has been successfully tested on the KEPCO systems which is comprised of 791-bus, 1575-branch and program PSS/E