• Title/Summary/Keyword: line source

Search Result 1,655, Processing Time 0.029 seconds

Packet Output and Input Configuration in a Multicasting Session Using Network Coding

  • Marquez, Jose;Gutierrez, Ismael;Valle, Sebastian;Falco, Melanis
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.2
    • /
    • pp.686-710
    • /
    • 2019
  • This work proposes a model to solve the problem of Network Coding over a one-session multicast network. The model is based on a system of restrictions that defines the packet flows received in the sink nodes as functions of the outgoing flows from the source node. A multicast network graph is used to derive a directed labeled line graph (DLLG). The successive powers of the DLLG adjacency matrix to the convergence in the null matrix permits the construction of the jump matrix Source-Sinks. In its reduced form, this shows the dependency of the incoming flows in the sink nodes as a function of the outgoing flows in the source node. The emerging packets for each outgoing link from the source node are marked with a tag that is a linear combination of variables that corresponds to powers of two. Restrictions are built based on the dependence of the outgoing and incoming flows and the packet tags as variables. The linear independence of the incoming flows to the sink nodes is mandatory. The method is novel because the solution is independent of the Galois field size where the packet contents are defined.

Analysis. Design and Control of Two-Level Voltage Source Converters for HVDC Systems

  • Mohan, D. Madhan;Singh, Bhim;Panigrahi, B.K.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.248-258
    • /
    • 2008
  • The Voltage Source Converter (VSC) is replacing the conventional line commutated current source converters in High Voltage DC (HVDC) transmission systems. The control of a two-level voltage source converter and its design dealt with HVDC systems and various factors such as reactive power, power factor, and harmonics distortion are discussed in detail. Simulation results are given for the two-level converter and designed control is used for bidirectional power flow. The harmonics minimization is taken by extending the 6-pulse VSC to multipulse voltage source converters. The control is also tested and simulated for a 12-pulse voltage source converter to minimize the harmonic distortion in AC currents.

A Phase Detection Method For Line Lock (전원동기를 위한 위상검출방법)

  • Kim, Young-Choon;Lee, Sa-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.428-430
    • /
    • 2007
  • Converter that is dc source equipment source's phase by reference control function that detect source's phase because should be done compulsorily use. Source's phase detect method there be method that use source's ac voltage directly by signal, and use methods that voltage detects status by PLL method and so on via point that '0' becomes usually. All above methods to detect phase are using, wrong action of phase detector converter's ailment or converter of burn can. Ths paper compares and examined usable phase detection method in source's frequency fluctuation presuming source's frequency using observer.

  • PDF

HIGH RESOLUTION $HC_3N$ OBSERVATIONS TOWARD THE CENTRAL REGION OF SAGITTARIUS B2

  • CHUNG HYUN SOO;OHISHI MASATOSHI;MORIMOTO MASAKI
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 1994
  • We have observed the emission of $HC_3N$ J=4-3, 5-4,10-9 and 12-11 transitions toward the Sgr B2 central region in an area of $150'\times150'$ with resolutions of 16'-48'. The intensities and central velocities of line profiles show significant variations with positions. In contrast to the intensities of the low J-level transitions which gradually increase from the central source toward the outside region, the $HC_3N$ emission of the high J-level transition become stronger toward 'the central radio continuum source MD5. Systematic change in the radial velocity of each line profile occurs along north-south direction. There are a few peaks in most line profiles, and these indicate that there are multiple velocity components along the line of sight. Distributions of excitation temperature and column density which were estimated from the excitation calculations show the existence of a small $(1\times2pc),\;hot\;(T_{ex}>50K)$ core which contains two temperature peaks at-15' east and north of MD5. The column density of $HC_3N\;is\;(1-3)\times10^{14}cm^{-2}$ Column density at distant position from MD5 is larger than that in the central region. We have deduced that this 'hot-core' has a mass of 105M 0, which is about an order of magnitude larger than those obtained by previous studies.

  • PDF

A Study of the Power Flow Control Using SSSC (SSSC를 이용한 전력조류제어에 관한 연구)

  • Na, Wan-Ki;Chung, Jai-Kil;Lee, In-Yong;Chung, In-Hark;Lee, Hong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.239-241
    • /
    • 2000
  • This paper describes a modeling of a FACTS(Flexible AC Transmission System) device, namely, SSSC(Static Synchronous Series Compensator) model. The SSSC, a solid-state voltage source inverter coupled with a transformer, is connected in series with a transmission line. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. The paper discusses the basic operating and performance characteristics of the SSSC, and power flow control in power system.

  • PDF

A Study on the corrosion property by post treatment in the metal dry etch (Metal 건식각 후처리에 따른 부식 특성에 관한 연구)

  • Mun, Seong-Yeol;Kang, Seong-Jun;Joung, Yang-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.747-750
    • /
    • 2007
  • This study proposes that chlorine residue after metal etch as the source of metal corrosion, and charges should be removed by optimizing etch, PR strip and cleaning condition. Charges distributed along the metal line acts as a source of tungsten (W) plug corrosion when associated with following cleaning solution. In cleaning process after metal etch and PR strip, chemical selection is significantly important in terms of metal corrosion. Optimal corrosion preventive PH, no metal attack (choice of optimal inhibitants), high by product removal efficiency and optimal de ionized water treatment condition is critical to the metal corrosion prevention.

  • PDF

A Field-based Morphing with Semi-automatic Control Lines Matching Using Image Segmentation (영상 분할을 이용한 반자동 제어선 정합에 의한 필드 기반 모핑)

  • Lee Hyoung-Jin;Kwak No-Yoon
    • Journal of Digital Contents Society
    • /
    • v.5 no.4
    • /
    • pp.269-274
    • /
    • 2004
  • The field based morping requires the user to set most of the control lines manually which require much time and skill to get satisfactory results. This tjesis proposes a method to acquire semi-automation of image morphing through first acquiring shape information from the source image and the target image, than after the user manually designates the least amount of a pair of feature points, these are used as standards for polygon based vertex to set the appropriate control line to the source image and target image, and then using the ratio of control line lengths and space. Using the proposed method the user can reduce the time setting the control line and unskilled persons can get natural image morphing results while desingnating the least amount of control line.

  • PDF

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

Analysis of Magnetic Fields induced by Line Currants using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1035-1037
    • /
    • 2005
  • The analysis of magnetic fields(2-D) induced by line currents, such as Overhead Trolley Lines or Transmission Lines, is not so easy by using the standard Finite Element Method(FEM). Mesh generation is one of the most important processes in the standard FEM. Because, the current region is relatively small compared with whole region, and actually is a line without thickness, the mesh refinement around the source lines yields many demerits. A way of supplement such a defect, we proposed the coupling scheme of analytical solution and FEM. In this study, the analytical solution is adopted around the region of line currents and FE solution is a lied to the rest of source region. And the two types of solution are coupled at the artificial boundary. To verify the usefulness of proposed algorithm, simplified model with magnetic material in FE region is chosen and analyzed. The results are compared with those of standard FEM. And the errors between them can be reduced by increasing harmonic orders.

  • PDF