• Title/Summary/Keyword: line slope

Search Result 559, Processing Time 0.024 seconds

Power Disturbance Detection using the Inflection Point Estimation (변곡점 추정을 이용한 전력선 신호의 이상현상 검출)

  • Iem, Byeong-Gwan
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.710-715
    • /
    • 2021
  • Power line signal can show disturbances due to various causes. Typical anomalies are temporary sag/swell of the amplitude, flat topped signal, and harmonic distortions. The disturbances need to be detected and treated properly for the quality of the power signal. In this study, the power disturbances are detected using the inflection points (IP). The inflection points are defined as points where local maxima/minima or the slope changes occur. The power line signal has a fixed IP pattern since it is basically sinusoidal, and it may have additional inflection points if there is any disturbance. The disturbance is detected by comparing the IP patterns between the normal signal and distorted signal. In addition, by defining a cost function, the time instant where the disturbance happens can be decided. The computer simulation shows that the proposed method is useful for the detection of various disturbances. The simple sag or swell signal only shows the amplitude changes at the detected inflection points. However, the flat top signal and harmonically distorted signal produce additional inflection points and large values in the cost function. These results can be exploited for the further processing of disturbance classification.

Salting-out Effects on the Partition of Proteins in Aqueous Two-phase Systems

  • KIM, CHAN-WHA;CHO KYUN RHA
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.5
    • /
    • pp.352-357
    • /
    • 1996
  • The partition of proteins in the salt-rich phase of polyethylene glycol (pEG)/salt aqueous two-phase systems is limited by the salting-out effects of salt. The logarithm of the concentration of proteins partitioned in the salt-rich phase decreases linearly with increases in the concentration of salt in the salt-rich phase (salting-out). Therefore, the partition of a given protein in the salt-rich phase of aqueous two-phase systems can be estimated from the salting-out constant. The slope of the solubility line (salting-out con-stant) for a given protein is determined by the type of salt in the two-phase systems.

  • PDF

Analysis of Schottky Barrier Height in Small Contacts Using a Thermionic-Field Emission Model

  • Jang, Moon-Gyu;Lee, Jung-Hwan
    • ETRI Journal
    • /
    • v.24 no.6
    • /
    • pp.455-461
    • /
    • 2002
  • This paper reports on estimating the Schottky barrier height of small contacts using a thermionic-field emission model. Our results indicate that the logarithmic plot of the current as a function of bias voltage across the Schottky diode gives a linear relationship, while the plot as a function of the total applied voltage across a metal-silicon contact gives a parabolic relationship. The Schottky barrier height is extracted from the slope of the linear line resulting from the logarithmic plot of current versus bias voltage across the Schottky diode. The result reveals that the barrier height decreases from 0.6 eV to 0.49 eV when the thickness of the barrier metal is increased from 500 ${\AA}$ to 900 ${\AA}$. The extracted impurity concentration at the contact interface changes slightly with different Ti thicknesses with its maximum value at about $2.9{\times}10^{20}\;cm^{-3}$, which agrees well with the results from secondary ion mass spectroscopy (SIMS) measurements.

  • PDF

Structural Analysis of the Valve Block of a Swash Plate-Type Axial Piston Pump (사판식 축 피스톤 펌프 밸브블록의 구조 해석에 관한 연구)

  • Kim, Jeong-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.3
    • /
    • pp.52-57
    • /
    • 2016
  • A swash plate-type piston pump is a device used to discharge hydraulic fluid as the volume generated through the piston moves in the direction of the slope by adjusting the angle of its swash plate. In addition, the valve block internalized in the pump includes a flow path for intake from outside, a flow path for discharge, and a pilot conduit line to control discharge pressure and flux. In this study, a numerical analysis is conducted to improve the cracking of the valve block generated during process testing, and the developed pump is evaluated.

Sliding mode controller design of BUCK converter (BUCK 콘버어터의 슬라이딩 모드 제어에 관한 연구)

  • Im, Dal-Ho;Kim, Hee-Jun;Son, Young-Dae;Oh, Won-Deok;Goo, Tae-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.508-511
    • /
    • 1991
  • In this paper, we have analyzed the transient and steady state characteristics of buck type DC-DC converter using the sliding mode control method based upon VSS. This control method provides the easier analysis tool due to the time domain analysis and the acquirement of desired transient characteristics if the slope of the switching line is properly selected, and guarantees the robustness against parameter uncertainties and load disturbances. Also, it can achieve direct nonlinear control without linearizing approximation of state space averaging method. PSPICE simulation results are then presented verifying these concepts.

  • PDF

The Analysis of the Slope Stability for the Small Dam (Small Dam의 斜面安定 解析)

  • Choi, Ki-Bong;Bae, Woo-Soek
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.88-92
    • /
    • 2004
  • The paper decribes a procedure for the evaluation of the effect of seepage force on stability of slopes. The stability of an embankment impounding a water reservoir is highly depend upon the location of seepage line with the embankment. To evaluate the accurate safety factor of an embankment, it is important to illustrate the seepage phenomenon. Of particular interest is the stability following a rapid change of reservoir level. Seepage forces in embankments are easily determined interest is the stability following a rapid change of resrvoir level. Seepage forces in embankments are easily detemined if frictional forces are expressed in relation to hydraulic gradient I. If a piezometer is inserted into a body of embankment, the level to which fee water rises is a measure of the energy at that point.

The Design of Digital Controller for Performance Improvement of Automation System (자동화 시스템의 성능 향상을 위한 디지틀 제어기 설계)

  • 조정환;이철직
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.5
    • /
    • pp.80-86
    • /
    • 1995
  • This paper proposes the design of new digital controller to improve control performance of automation system. The proposed controller improves response time and steady state error in the driving a system to generate a output voltage proportional to the frequency difference of reference input signal and feedback signal, holds good stability and higher accuracy designing an adaptive line density selector and a quantized level controller of slope-varied type. A theoretical and experimental studies have been carried out. Th presented results how the improved performance in the position control of automation system.

  • PDF

Modular Photovoltaic PCS with High-frequency Isolation (고주파 절연 모듈형 Photovoltaic PCS)

  • Kwon Jung-Min;Kwon Bong-Hwan
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.11-18
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The dc current of the PV array is estimated without using a dc current sensor The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

A Study on DC Power Regeneration for Railway using Parallel PWM Converter (병렬 PWM 컨버터를 이용한 철도차량 직류 전력 회생장치에 관한 연구)

  • Lee Jong-Moo;Jang Su-jin;Song Sang-Hun;Won Chung-Yuen;Ahn Kyu-Bok;Lee Joon-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.524-527
    • /
    • 2004
  • When the electric tractions are stopped or driven through the falling slope way, it occured to surplus energy in the DC power line. At present, these energy are exhausted by breaking-system. The converter is not only capable of feeding energy back into the AC source during excessive regeneration. It is issued for this surplus energy regenerating system. These systems are faced with high voltage and high power for railway DC power regeneration. This paper proposed a parallel PWM converter how to solve these problem.

  • PDF

Simultaneous Measurements of Stress and Birefringence Development during Extensional Deformation of Cyclic Olefin Copolymer

  • Yagisawa, Yusuke;Ito, Hiroshi;Kikutani, Takeshi
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.361-361
    • /
    • 2006
  • To clarify the structure development of cyclic olefin copolymers in stretching and relaxation processes, on-line measurements of optical retardation and tensile force were performed. Birefringence increased continuously whereas stress showed yielding at stretching temperatures of $160^{\circ}C$. At $170^{\circ}C$, stress yielding was not observed and stress and birefringence increased monotonously with an increase in the strain. In the relaxation process, stress and birefringence decreased monotonously at all the temperatures examined. The slope for the stress vs. birefringence relation at initial stage of stretching increased with an increase in temperature, whereas that for the relaxation stage was significantly larger that for the stretching process, and therefore showed a significant hysteresis.

  • PDF