• Title/Summary/Keyword: line sampling

Search Result 374, Processing Time 0.029 seconds

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Environmental Impact Assessments along with Construction of Residential and Commercial Complex (주거단지 건설이 하천에 미치는 생태영향평가)

  • An, Kwang-Guk;Han, Jeong-Ho;Lee, Jae Hoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.631-648
    • /
    • 2012
  • The integrative ecological approaches of chemical assessments, physical habitat modelling, and multi-metric biological health modelling were applied to Gwanpyeong Stream within Gap-Stream watersheds to evaluate environmental impacts on the constructions of residential and commercial complex. For the analysis, the surveys conducted from 45 sites of reference streams within the Gap-Stream watershed and 3 regular sites during 2009 - 2010. Physical habitat health, based on the habitat model of Qualitative Habitat Evaluation Index(QHEI) declined from the headwaters(good - fair condition) to the downstream(poor condition). Chemical water quality, based turbidity and electric conductivity(EC), was degraded toward to the downstream, and especially showed abrupt increases, compared to the values of control streams(CS). Also, concentrations of chlorophyll-a in the downstreams were greater compared to the control stream(CS), indicating an eutrophication. Biological health conditions, based on the Index of Biological Integrity(IBI) using fish assemblages, averaged 19.3 which is judged as a fair condition by the biological criteria of the Ministry of Environment, Korea. The comparisons of model metric values in sensitive species and riffle-benthic species on the Maximum Species Richness Line(MSRL) of 45 reference streams indicated a massive disturbances in all sampling locations. Also, tolerance guild and trophic guild analyses suggest that dominances of tolerant species and omnivores were evident, indicating a biological degradation by habitat disturbances and organic matter pollutions. There was no distinct longitudinal variations of IBI model values from the headwater to the downstream in spite of slight chemical and habitat health gradients among the sampling sites. Overall, integrative ecological health(IEH) scores, based on the chemical, physical, and biological parameters, were low compared to the 45 reference streams due to physical and chemical disturbances of massive constructions of the residential and commercial complex. This stream, thus showed a tendency of typical urban streams which are disturbed in the chemical water quality, habitat structures, and biological integrity. Effective stream management plans and restoration strategies are required in this urban stream for improving integrative stream health.

Quantitative Exposure Assessment of Various Chemical Substances in a Wafer Fabrication Industry Facility

  • Park, Hyun-Hee;Jang, Jae-Kil;Shin, Jung-Ah
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • Objectives: This study was designed to evaluate exposure levels of various chemicals used in wafer fabrication product lines in the semiconductor industry where work-related leukemia has occurred. Methods: The research focused on 9 representative wafer fabrication bays among a total of 25 bays in a semiconductor product line. We monitored the chemical substances categorized as human carcinogens with respect to leukemia as well as harmful chemicals used in the bays and substances with hematologic and reproductive toxicities to evaluate the overall health effect for semiconductor industry workers. With respect to monitoring, active and passive sampling techniques were introduced. Eight-hour long-term and 15-minute short-term sampling was conducted for the area as well as on personal samples. Results: The results of the measurements for each substance showed that benzene, toluene, xylene, n-butyl acetate, 2-methoxy-ethanol, 2-heptanone, ethylene glycol, sulfuric acid, and phosphoric acid were non-detectable (ND) in all samples. Arsine was either "ND" or it existed only in trace form in the bay air. The maximum exposure concentration of fluorides was approximately 0.17% of the Korea occupational exposure limits, with hydrofluoric acid at about 0.2%, hydrochloric acid 0.06%, nitric acid 0.05%, isopropyl alcohol 0.4%, and phosphine at about 2%. The maximum exposure concentration of propylene glycol monomethyl ether acetate (PGMEA) was 0.0870 ppm, representing only 0.1% or less than the American Industrial Hygiene Association recommended standard (100 ppm). Conclusion: Benzene, a known human carcinogen for leukemia, and arsine, a hematologic toxin, were not detected in wafer fabrication sites in this study. Among reproductive toxic substances, n-butyl acetate was not detected, but fluorides and PGMEA existed in small amounts in the air. This investigation was focused on the air-borne chemical concentrations only in regular working conditions. Unconditional exposures during spills and/or maintenance tasks and by-product chemicals were not included. Supplementary studies might be required.

A Real Time Monitoring for Water Quality of River (수질자동모니터링시스템의 설치 현황과 전망)

  • Ryu, Jae-Kuen
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.

Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis (대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용)

  • Park, Seung-Shik;Ko, Jae-Min;Lee, Dong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.

Random Digit Dialing Telephone Survey and Major Findings (RDD 전화조사와 주요결과)

  • Kang, H.C.;Han, S.T.;Kim, J.Y.;Jung, Y.C.;Huh, M.H.
    • Survey Research
    • /
    • v.9 no.1
    • /
    • pp.1-22
    • /
    • 2008
  • Telephone directories ille still being used as the sampling frame in almost all fixed-line telephone surveys in Korea, causing potentially serious coverage error. RDD (random digit dialing) sampling is an obvious alternative to solve the problem. The aim of this paper is twofold: 1) proposal of RDD methodology suitable to the telephone system of Korea and 2) the identification of socio-demographic and socio-psychological differences between listed-number and unlisted-number respondents. Major findings of RDD telephone survey conducted experimental]y are as follows. 1) Population coverage by telephone directories is 60% or less. 2) Unlisted-number households have statistically larger income compared to listed-number households. 3) Unlisted-number households have smaller family size compared to listed-number households. 4) Unlisted-number respondents are more sensitive about confidentiality, leaks, 5) Unlisted-number respondents are more liberal compared to unlisted-number respondents. These facts suggest that directory-based telephone surveys tend to be biased in socio-economic aspects.

  • PDF

Effectiveness of Worksite Intervention on Stress Management: An Analytic Literature Review

  • Park Kyoung-Ok
    • Korean Journal of Health Education and Promotion
    • /
    • v.21 no.4
    • /
    • pp.15-33
    • /
    • 2004
  • With growing significance of psychological well-being in the worksite, the purpose of this analysis was to overview the empirical studies on worksite stress management and to identity the overall effect of worksite health promotion programs on stress management through meta-analysis. Literature retrieval was conducted on-line first in MEDLINE, EBSCOhost Academic Search Premier, and PSYCHINFO databases in public health, psychology, sociology, and human resource management areas. All studies written in English and published in the peer-reviewed journals during 1990 and 2002 were recruited. Key words used in literature retrieval were 'worksite,' 'intervention,' 'program,' 'work stress,' 'strain,' 'burnout,' 'management,' 'prevention,' 'education,' and 'health promotion.' A total of 18 worksite intervention studies with 48 effect sizes were analyzed and the results were as follows. Approximately 60% of the studies had quasi-experimental design and were conducted in manufacturing company and public sector. General psychological strains and burnout were frequently used measures of psychological stress. The lecturing and discussion typed intervention and the participatory problem-solving typed intervention were employed more than others in the studies. The average effect (r: pearson's simple correlation coefficient) weighted by sampling error was -0.14 (-0.32 to 0.05). In the conventional category of effects this is a small effect ranging from -0.59 to 0.05. Binomial effect size showed that success rates increased from 43% without intervention to 57% after an intervention. Sampling error explained 47.14% of the observed variance and its effectiveness on stress management were heterogeneous. In regression analysis with suspected moderating factors affecting the worksite interventions, research design was the only significant moderating factor. The studies with quasi-experimental design had greater effects than the studies with experimental design.

A Study on Frame of MSE Comparison for Scene Chang Detection Retrieval (장면 전환점 검출을 위한 프레임의 평균오차 비교에 관한 연구)

  • 김단환;김형균;오무송
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.638-642
    • /
    • 2002
  • User in video data utilization of high-capacity can grasp whole video data at a look. Offer frame list that summarize information of video data to do so that can remake video from branch that want when need. Need index process of video data for effective video retrieval. This treatise wishes to propose effective method about scene change point detection of video that is been based on contents base index. Proposed method video data so that can grasp whole structure of video detection color value of schedule pixel for diagonal line direction in image sampling do. Data that get into sampling could grasp scene change point on one eye. Color value of pixel that detection in each frame is i frame number by i$\times$j procession to procession A, j stores to reflex height of frame. Introduce MSE and calculate mean error of each frame. If exceed mean error and schedule critical value, wish to detect the frame for scene change point.

  • PDF

Extreme Value Analysis of Statistically Independent Stochastic Variables

  • Choi, Yongho;Yeon, Seong Mo;Kim, Hyunjoe;Lee, Dongyeon
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.222-228
    • /
    • 2019
  • An extreme value analysis (EVA) is essential to obtain a design value for highly nonlinear variables such as long-term environmental data for wind and waves, and slamming or sloshing impact pressures. According to the extreme value theory (EVT), the extreme value distribution is derived by multiplying the initial cumulative distribution functions for independent and identically distributed (IID) random variables. However, in the position mooring of DNVGL, the sampled global maxima of the mooring line tension are assumed to be IID stochastic variables without checking their independence. The ITTC Recommended Procedures and Guidelines for Sloshing Model Tests never deal with the independence of the sampling data. Hence, a design value estimated without the IID check would be under- or over-estimated because of considering observations far away from a Weibull or generalized Pareto distribution (GPD) as outliers. In this study, the IID sampling data are first checked in an EVA. With no IID random variables, an automatic resampling scheme is recommended using the block maxima approach for a generalized extreme value (GEV) distribution and peaks-over-threshold (POT) approach for a GPD. A partial autocorrelation function (PACF) is used to check the IID variables. In this study, only one 5 h sample of sloshing test results was used for a feasibility study of the resampling IID variables approach. Based on this study, the resampling IID variables may reduce the number of outliers, and the statistically more appropriate design value could be achieved with independent samples.

Natural Regeneration Potential of the Soil Seed Bank of Land Use Types in Ecosystems of Ogun River Watershed

  • Asinwa, Israel Olatunji;Olajuyigbe, Samuel Olalekan
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.3
    • /
    • pp.141-151
    • /
    • 2022
  • Soil seed banks as natural storage of plant seeds play an important role in the maintenance and regeneration of watershed. Natural regeneration potential of the soil seed bank of Land use types (LUTs) in Ogun River watershed (ORW) was investigated. ORW was stratified using proportionate sampling technique into Guinea Savannah (GS), Rainforest (RF) and Swamp Forest (SF) Ecological Zones (EZs). Three LUTs: Natural Forest (NF), Disturbed Forest (DF) and Farmland (FL) were purposively selected in GS: GSNF, GSDF, GSFL; RF: RFNF, RFDF, RFFL and SF: SFNF, SFDF, SFFL, respectively. Systematic line transects was used in the laying of the sample plots. Sample plots of 25 m×25 m were established in alternate positions. Ten 1 m×1 m quadrats were randomly laid for soil core sampling from previously randomly selected ten plots. The core samples (10) were pooled per plot in each LUT and placed in individual trays. Ten trays with sterilized soil were used as control. The trays were watered regularly and checked for seedlings emergence fortnightly for 18 months. The experimental design used was 3×3 factorial experiments. ANOVA, Diversity index (H') and Similarity index (SI) were used to analyze the data. There was significant difference in seedling emergence among ecological zones and land use types (p<0.05). A total of 4,400 seedlings emerged from the soil samples. All species were distributed among 32 families. FL in the RF had the highest number of germinated seeds (705±37.33 seedlings) followed by DF in the RF (701±49.6 seedlings). The lowest emergence was in NF of the SF (199±28.41 seedlings). DF in the RF had highest number of species (34) distributed among 22 families. Emergence from soil seed bank of NF in ORW was generally with more of tree species than herbs that were predominant in FL and DF.