A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere  

Son, Eun-Seong (Department. of Environmental Engineering, Yeungnam University)
Seo, Young-Kyo (Department. of Environmental Engineering, Yeungnam University)
Lee, Dong-Hyun (Department. of Environmental Engineering, Yeungnam University)
Lee, Min-Do (National Institute of Environmental Research)
Han, Jin-Seok (National Institute of Environmental Research)
Baek, Sung-Ok (Department. of Environmental Engineering, Yeungnam University)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.25, no.6, 2009 , pp. 523-538 More about this Journal
Abstract
Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.
Keywords
VOCs; Benzene; On-line GC; Adsorbents; NPD; ECD; TO-17; Nafion dryer;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Baek, S.O., K.H. Kim, and G.S. Heo (2004) Air quality measurements and QC/QA (I) - principles and methodology, Korean J. of Atmos. Environ., 20(2), 237-249. (in Korean with English abstract)
2 Field, R.A., M.E. Goldstone, J.N. Lester, and R. Perry (1992) The sources and behaviour of tropospheric anthropogenic voaltile organic compounds. Atmos. Environ., 26A, 2983-2996
3 Heavner, D.L., M.W. Ogden, and P.R. Nelson (1992) Multisorbent thermal desorption/gas chromatography/mass selective detection method for the determination of target volatile organic compounds in indoor air, Environ. Sci. Technol., 26, 1737-1746   DOI
4 Park, J.H., Y.K. Seo, and S.O. Baek (2006) A study on the comparison of atmospheric concentrations of volatile organic compounds in a large urban area and a suburban area, Korean J. of Atmos. Environ., 22(6), 767-778. (in Korean with English abstract)
5 Shaw, S.L. (2001), The production of non-methane hydrocarbons by marine plankton, Doctoral Thesis, MIT, 138-140
6 UKDOE(2007) http://www.airquality.co.uk/archive/networks_home.php (accessed 2007.10.10)
7 Woolfenden, E. (1997) Monitoring VOCs in air using sorbent tubes followed by thermal desorption-capillary GC analysis, J. Air Waste Manage. Assoc., 47, 20-36   DOI
8 Martin, N.A., D.J. Marlow, M.H. Henderson, B.A. Goody, and P.G. Quincey (2003) Studies using the sorbent Carbopack X for measuring environmental benzene with Perkin Elmer type pumped and diffusive samplers, Atmos. Environ., 37, 871-879   DOI   ScienceOn
9 Baek, S.O. and Y.H. Moon (2004) Evaluation of adsorbent sampling methods for volatile organic compounds in indoor and outdoor air, Korean J. of Anal. Sci. Technol., 17(6), 496-513. (in Korean with English abstract)
10 Korea MOE (2006) Enforcement decree of the framework act on environmental policy, President Executive Directive No. 21621
11 USEPA(1997) Compendium of methods TO-17, Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes, 2nd Ed., EPA/625/R-96/010b
12 Oliver, K.D., W.A. McClenny, and E.H. Daughtrey (1995) Analysis of VOCs in ambient air using multisorbent packings for VOCs accumulation and sample drying, J. Air Waste Manage. Assoc., 45, 792-800   DOI
13 USEPA (1990) Definition and procedure for the determination of the method detection limit, 40 CFR Part 136 (analytical procedure), appendix B, 319-321
14 WHO(2000) Guidelines for Air Quality, geneva, 2000
15 USEPA (1999) Compendium of Methods TO-14A, Determination of volatile organic compounds in ambient air using specially prepared canisters with subsequent analysis by gas chromatography, 2nd Ed., EPA/625/R-96/010b
16 Baek, S.O. (2006) A study on hazardous air pollutants in Siwha and Banwol industrial area, Final Report of NIER. 109-169
17 Ma, C.Y., J.T. Skeen, A.B. Dindal, C.K. Bayne, and R.A. Jenkins (1997) Performance ealuation of a thermal desorption/ gas chromatographic/mass spectrometric method for the characterization of waste tank headspace samples, Environ. Sci. Technol., 31, 853-859   DOI   ScienceOn
18 Korea MOE (2005) Additional specification of HAPs 10 species including ethylbenzene and hydrazine, etc., Ministry of Environment Official Press Release (2005. Oct. 5th)
19 McClenny, W.A., M.W. Holdren, K.D. Oliver, J.D. Pleil, G.F. Evans, and W.T. Winberry (1991) Canister-based method for monitoring toxic VOCs in ambient air, J. Air Waste Manage. Assoc., 41, 1308-1318   DOI   ScienceOn
20 Ogle, L.D., D.A. Brymer, and R.L. Carlson (1993) Detector selection for the analysis of volatile organic air toxic compounds using U.S. EPA conpendium method TO14. In Sampling and Analysis of Air Pollutants. Edited by E.D. Winegar and L.H. Keith, Lewis Pub., Boca Raton, 103-131