• 제목/요약/키워드: line impedance

검색결과 936건 처리시간 0.025초

대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석 (Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current)

  • 임용훈;현덕화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF

인식거리 향상을 위한 UHF 대역 RFID 태그 임피던스 정합 설계 (Impedance Tuning and Matching Characteristics of UHF RFID Tag for Increased Reading Range)

  • 이종욱;권홍일;이범선
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.279-284
    • /
    • 2005
  • We investigated the impedance matching characteristics of UHF-band RFID tag antenna and tag chip for increased reading range. A voltage multiplier designed using 0.4 $\mu$m zero-$V_T$ MOSFET showed that DC output voltage of about 2 V can be obtained using standard CMOS process. The input impedance of the voltage multiplier was examined to achieve impedance matching to the RFID tag antenna using analytical and numerical approaches. The input impedance of the voltage multiplier could be varied in a wide range by selecting the size of MOSFET and the number of multiplying stages, and thus can be impedance matched to a tag antenna in presence of other tag circuit blocks. A meander line inductively-coupled RFID tag antenna operating at UHF band also shows the feasibility of impedance matching to tile RFID tag chip.

  • PDF

Extended Fault Location Algorithm Using the Estimated Remote Source Impedance for Parallel Transmission Lines

  • Ryu, Jeong-Hun;Kang, Sang-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2212-2219
    • /
    • 2018
  • This paper describes extended fault location algorithm using estimated remote source impedance. The method uses data only at the local end and the sequence current distribution factors for more accurate estimation. The proposed algorithm can respond to variation of the local and remote source impedance. Therefore, this method is especially useful for transmission lines interconnected to a wind farm that the source impedance varies continuously. The proposed algorithm is very insensitive to the variation in fault distance and fault resistance. The simulation results have shown the accuracy and effectiveness of the proposed algorithm.

SEAMLESS 관의 마찰손실에 따른 작동유체의 임피던스 특성 (Impedance Characteristics of operate fluid about Frictional loss in seamless pipeline)

  • 모양우;유영태;최병재
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.304-310
    • /
    • 2001
  • Flow pulsation often causes vibration and noise in piping systems and therefore has been a troublesome concern for fluid system engineers. According to frequency increase in this paper under the influence wave form of velocity in springly flow and viscosity are drop coefficient of viscosity become increase so that impedance and resistance. The transient variations of flow rate are measured by a modified impedance tube method which is realized by virtue of the present analytical technique. At pipe line in order to eliminate vibration, confirm happened intermittently impedance characteristics. We make a test and frequency analysis and have to minimize obstructive component at hydraulic circuit.

  • PDF

전력계통의 고임피던스 고장 검출 기법에 관한 연구 (A Study on High Fault Detection In Power System)

  • 임화영;유창완;고재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권1호
    • /
    • pp.16-21
    • /
    • 1999
  • The analysis of distribution line faults is essential to the proper protections of the power system. A high impedance fault test, which was carried in Korean electric power systems, it was found that a arcing phenomenon occurred during the high level portion of conductor voltage in each cycle. In this paper, we propose a new method for detection of high impedance faults, which uses the arcing fault current difference during high voltage and low voltage portion of conductor voltage waveform. To extract this difference, we diveded one cycle fault current into equal spanned four data windows according to the magnitude of voltage waveform and applied fast fourier transform(FFT) to each data window. The frequency spectrum of current wavefrom in each portion are used as the inputs of neural network and is trained to detect high impedance faults. The proposed method shows improved accuracy when applied to staged fault data and fault-like load.

  • PDF

시간지연 신경회로망을 이용한 고장지락사고 검출 (Detection of High Impedance Fault based on Time Delay Neural Network)

  • 최진원;이종호;김춘우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.405-407
    • /
    • 1994
  • In order to provide reliable power service and to prevent a potentail hazard and damage, it is important to detect high impedance fault in power distribution line. This paper presents a neural network based approach for the detection of high impedance faults. A time delay neural network has been selected and trained for the fault currents obtained from field experiments. Detection experiments have been performed with the data from four different high impedance surfaces. Experimental results indicated the feasibility of using TDNN for the detection of high impedance faults.

  • PDF

고조파 상태 공간 출력임피던스에 기반한 DC-DC 부스트 컨버터의 안정도 해석 (Stability Analysis of DC-DC Boost Converters Based on Output Impedance in HSS)

  • 헤리얀토누르;박범수;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.455-456
    • /
    • 2020
  • This paper proposes stability evaluation of DC/DC boost converters based on output impedance in harmonic transfer function matrix considering line impedance and cascaded voltage and current control loops. The harmonic state-space (HSS) model of converter and controller is developed to obtain the harmonic transfer function matrix of closed-loop output impedance. This work is useful for impedance-based stability analysis of converters connected to DC power systems.

  • PDF

실측 동기화 데이터를 활용한 교류전기철도의 고장점표정장치 임피던스 예측기법 연구 (Study on the Railway Fault Locator Impedance Prediction Method using Field Synchronized Power Measured Data)

  • 전용주;김재철
    • 한국철도학회논문집
    • /
    • 제20권5호
    • /
    • pp.595-601
    • /
    • 2017
  • 전철화 확대의 영향으로 전차선로 변의 고장발생 빈도는 지속적으로 증가하여, 고장위치를 표정하는 시스템의 중요도는 향상되고 있다. 그럼에도 전차선로의 정확한 고장위치 표정은 매우 어려운 현실이다. 본 논문에서는 기존 회로방정식으로 제안된 전차선로 임피던스 계산이론에 대해 현장실측 데이터를 활용하여 보편화 정리하고 변전소 및 운행차량의 전압, 전류 데이터를 동기화 실측하여 전차선로의 임피던스를 예측 하였다. 또한 예측된 전차선로 임피던스값의 유효성 확인을 위해 동일지점에서 열차전류에 따른 임피던스 변화 정도를 시뮬레이션으로 확인하였다. 끝으로 측정 데이터와 지락시험을 통한 데이터를 비교 분석하였다. 본 기법은 강제지락시험, 인공지락시험을 통해 임피던스를 예측하는 현행 방식 대비 열차운행 중단 없이 다수의 데이터를 확보할 수 있고 시간경과에 따른 임피던스 변화에 대해서도 신속하고 편리하게 대응할 수 있는 장점이 있는 것으로 판단된다.

비균일 전송선의 기존 해석에 관한 연구 (A Study on Conventional Analysis of Nonuniform Transmission Line)

  • 김세윤;하현태;홍성용
    • 한국전자파학회지:전자파기술
    • /
    • 제2권3호
    • /
    • pp.3-9
    • /
    • 1991
  • 본 연구에서는 비균일 전송선의 특성분석에 사용되는 기존 해석 방법들의 유용성과 한계점에 관하여 살펴보았다. 기존 해석 방법으로 구한 지수함수 형태로 변하는 비균일 전송선의 입력 임피던스는 특정한 조건하에서만 해의 유일성을 잦음을 알았다. 또한 각잔 두 평판으로 구성된 전송선의 입력 임피던스를 기존의 평면 TEM 모우드를 이용하여 구한 값이 정확한 해와 오차가 생김을 보였다.

  • PDF

구형 혼안테나에 인접된 전송선로에 유기되는 부하전류 및 EMI 특성 해석 (An Analysis of EMI Characteristics and the Induced Load Current on th Transmission Line Being Close to the Rectangular Horn Antenna)

  • 양두영;채관수;이상설
    • 한국통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.335-341
    • /
    • 1991
  • 구형 혼안테나에 의한 EMI문제를 해결하기 위하여 근거리 영역에 대한 복사 전자계식을 세운다. 전자계 해석 방법과 전송선이론을 적용하여 인접한 전송선 부하에 흐르는 EMI 부하전류를 계산한다. 거리와 주파수 및 송, 수전단 임피던스에 따른 부하전류 전달함수로 부터 EMI의 최소화조건을 찾아낸다. 송전단 임피던스가 작아질수록 EMI 부하전류는 커지고 송전단 임피던스가 커질수록 EMI 부하전류는 작아진다.

  • PDF