• 제목/요약/키워드: line: identification

검색결과 749건 처리시간 0.027초

Human Memorable Password based Efficient and Secure Identification

  • Park Jong-Min
    • Journal of information and communication convergence engineering
    • /
    • 제3권4호
    • /
    • pp.213-216
    • /
    • 2005
  • Almost all network systems provide an authentication mechanism based on user ID and password. In such system, it is easy to obtain the user password using a sniffer program with illegal eavesdropping. The one-time password and challenge-response method are useful authentication schemes that protect the user passwords against eavesdropping. In client/server environments, the one-time password scheme using time is especially useful because it solves the synchronization problem. It is the stability that is based on Square Root Problem, and we would like to suggest PBI(password Based Identification), enhancing the stability, for all of the well-known attacks by now including Off-line dictionary attack, password file compromise, Server and so on. The PBI is also excellent in the aspect of the performance.

An On-Line Fuzzy Identification Method utilizing Fuzzy Model Evaluation

  • Bae, Sang-Wook;Park, Tae-Hong-;Lee, Kee-Sang-;Park, Gwi-Tae-
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1226-1229
    • /
    • 1993
  • This paper proposes a new on-line fuzzy model identification(ONFID) algorithm in which the fuzzy model evaluation stage is incorporated. The fuzzy model evaluation is performed by the fuzzy equality index which is known to be a useful tool to evaluate the performance of the identified fuzzy model. Then the fuzzy model is updated according to the result of the evaluation. Proposed ONFID algorithm can sensibly identify to the system changes. To show the usefulness of the proposed algorithm, it is applied to the fuzzy model identification problem of the gas furnace and the output prediction problem of the flexible joint manipulator which is a nonlinear system.

  • PDF

VLSI 논리설계 최적화를 위한 Redundancy 조사 가속화에 관한 연구 (On the Acceleration of Redundancy Identification for VLSI Logic Optimization)

  • 이성봉;정정화
    • 대한전자공학회논문지
    • /
    • 제27권3호
    • /
    • pp.131-136
    • /
    • 1990
  • 본 논문에서 게이트레벨 회로의 논리 최적화를 위한 논리적 redundancy조사를 가속화하는 새로운 방법을 제안한다. 게이트레벨 회로의 redundancy 조사문제는 테스트패턴 생성문제와 마찬가지로 유한상태 탐색문제로서, 그 실행시간이 탐색의 크기에 의존한다. 본 논문에서는 효율적인 탐색을 위해, '동적 head line'과 'mandatory 할당' 방법을 제안한다. 동적 head line은 redundancy조사과정에서 동적으로 변경되어, 탐색에서의 backtracking 수를 감소기키며, mandatory 할당은 불필요한 할당을 피할 수 있어 탐색의 크기를 줄인다. 특히 이들 방법은 기존의 테스트패턴 생성문제에서 사용한 방법과는 달리, 회로 최적화에 따른 회로의 변경에 영향을 받지 않고 사용된다. 또한, 이들 방법을 기존의 redundancy 조사시스템에 실현하여, 그 유효성을 보인다.

  • PDF

변분법을 이용한 재귀신경망의 온라인 학습 (A on-line learning algorithm for recurrent neural networks using variational method)

  • 오원근;서병설
    • 제어로봇시스템학회논문지
    • /
    • 제2권1호
    • /
    • pp.21-25
    • /
    • 1996
  • In this paper we suggest a general purpose RNN training algorithm which is derived on the optimal control concepts and variational methods. First, learning is regared as an optimal control problem, then using the variational methods we obtain optimal weights which are given by a two-point boundary-value problem. Finally, the modified gradient descent algorithm is applied to RNN for on-line training. This algorithm is intended to be used on learning complex dynamic mappings between time varing I/O data. It is useful for nonlinear control, identification, and signal processing application of RNN because its storage requirement is not high and on-line learning is possible. Simulation results for a nonlinear plant identification are illustrated.

  • PDF

소프트웨어 Fault Tolerance를 이용한 고장점 표정 (Fault Location Identification Using Software Fault Tolerance Technique)

  • 김원하;장용원;한승수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.73-78
    • /
    • 2005
  • The management of technological systems will become increasingly complex. Safe and reliable software operation is a significant requirement for many types of system. So, with software fault tolerance, we want to prevent failures by tolerating faults whose occurrences are known when errors are detected. This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line using software fault tolerance technique. To find the fault location of transmission line, we have to solve the 3rd order transmission line equation. A significant improvement in the identification of the fault location was accomplished using the N-Version Programming (NVP) design paradigm. The delivered new algorithm has been tested with the simulation data obtained from the versatile EMTP simulator.

Parameters On-line Identification of Dual Three Phase Induction Motor by Voltage Vector Injection in Harmonic Subspace

  • Sheng, Shuang;Lu, Haifeng;Qu, Wenlong;Guo, Ruijie;Yang, Jinlei
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.288-294
    • /
    • 2013
  • This paper introduces a novel method of on-line identifying the stator resistance and leakage inductance of dual three phase induction motor (DTPIM). According to the machine mathematical model, the stator resistance and leakage inductance can be estimated using the voltage and current values in harmonic subspace. Thus a method of voltage vector injection in harmonic subspace (VVIHS) is proposed, which causes currents in harmonic space. Then the errors between command and actual harmonic currents are utilized to regulate the machine parameters, including stator resistance and leakage inductance. The principle is presented and analyzed in detail. Experimental results prove the feasibility and validity of proposed method.

온라인 식별 및 매개변수 추정을 이용한 실시간 e-Actuator 오류 검출 (Realtime e-Actuator Fault Detection using Online Parameter Identification Method)

  • 박준기;김태호;이흥식;박찬식
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.376-382
    • /
    • 2014
  • E-Actuator is an essential part of an eVGT, it receives the command from the main ECU and controls the vane. An e-Actuator failure can cause an abrupt change in engine output and it may induce an accident. Therefore, it is required to detect anomalies in the e-Actuator in real time to prevent accidents. In this paper, an e-Actuator fault detection method using on-line parameter identification is proposed. To implement on-line fault detection algorithm, many constraints are considered. The test input and sampling rate are selected considering the constraints. And new recursive system identification algorithm is proposed which reduces the memory and MCU power dramatically. The relationship between the identified parameters and real elements such as gears, spring and motor are derived. The fault detection method using the relationship is proposed. The experiments with the real broken gears show the effectiveness of the proposed algorithm. It is expected that the real time fault detection is possible and it can improve the safety of eVGT system.

A FAST REDUCTION METHOD OF SURVEY DATA IN RADIO ASTRONOMY

  • LEE YOUNGUNG
    • 천문학회지
    • /
    • 제34권1호
    • /
    • pp.1-8
    • /
    • 2001
  • We present a fast reduction method of survey data obtained using a single-dish radio telescope. Along with a brief review of classical method, a new method of identification and elimination of negative and positive bad channels are introduced using cloud identification code and several IRAF (Image Reduction and Analysis Facility) tasks relating statistics. Removing of several ripple patterns using Fourier Transform is also discussed. It is found that BACKGROUND task within IRAF is very efficient for fitting and subtraction of base-line with varying functions. Cloud identification method along with the possibility of its application for analysis of cloud structure is described, and future data reduction method is discussed.

  • PDF

System Identification Method를 이용한 DC/DC 컨버터 상태진단 (A Operating Status Diagnosis of DC/DC Converter by System Identification)

  • 김철우;김태진
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.724-729
    • /
    • 2007
  • In this paper, we propose a new diagnosis method of DC/DC converter aging. The method is based on variations of the parasitic resistor for the aging process. We apply an on-line diagnosis of the DC/DC converter because the observation is not a device, but a system. This study proposes a method of DC/DC converter diagnosis by analyzing the variations of model on the variations of parasitic resistor.