• Title/Summary/Keyword: limitation

Search Result 8,420, Processing Time 0.033 seconds

Design Parameter Study on the Isolation Performance of the HSLDS Magnetic Vibration Isolator (HSLDS 마그네틱 진동절연체의 절연성능에 대한 설계 파라미터 분석)

  • Shin, Ki-Hong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.92-97
    • /
    • 2010
  • In general, the softer the stiffness of a linear vibration isolator the better the performance of isolation can be achieved. However, the stiffness of the isolator cannot be made too soft because it needs a sufficient stiffness to hold the load. This is the most critical limitation of a linear vibration isolator. Recently, a HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was proposed to overcome this fundamental limitation. The suggested isolator utilizes two pairs of attracting magnets that introduces negative stiffness. Previously, this new type of vibration isolator was merely introduced and showed a possibility of practical use. In this paper, detailed dynamics of the HSLDS magnetic isolator are studied using computer simulations. Then, the isolation performance is examined for various design parameters to aid the practical use.

Parametric study on Continuous Welded Rail and Bridge interaction (장대레일 궤도와 교량의 상호작용에 대한 매개변수 분석)

  • Kim, Jong-Min;Han, Sang-Yun;Lim, Nam-Hyoung;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.303-306
    • /
    • 2007
  • CWR(Continuous Welded Rail) and bridge interaction produce rail force, bridge displacement and rail/bridge relative displacement. Each of these has limitation by many codes. In this paper, analysis of interaction has been carried out by using foreign codes(UIC 774-3 R code of Europe etc.) because there is no code about interaction between rail and bridge in Korea. Recently, railway bridges with CWR has been constructed for structural and economical reasons. When designer plans railway bridges, design a bridge model first and then investigate railway forces and displacement by interaction analysis. If these results go out bounds from limitation, designer plans railway bridges again and again. In this paper, using the parametric study on CWR and railway bridge interaction, railway bridge parameters such as length of bridge span, area of bridge, moment of inertia, stiffness of pier, etc. are presented. It helps preliminary design of railway bridges.

  • PDF

Bandwidth Limitation of Downstream Traffic of EPON (EPON에서 하향 데이터 트래픽의 대역폭 제한)

  • Goo Jahwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.5 s.335
    • /
    • pp.1-4
    • /
    • 2005
  • This paper deals with the mechanism and control protocols required in order to reconcile the P2MP topology into the Ethernet framework. This paper specifies the multi-point control protocol(MPCP) to operate an optical multi-point network. Also it is applied to method of bandwidth limitation of downstream traffic

Effect of nitrogen sources on production of exopolymer by Pseudomonas elodea ATCC 31461

  • Lee, Nam-Gyu;Kim, Hyeon-Suk;Seo, Hyeong-Pil;Jeong, Dae-Yeong;Kim, Ji-Mo;Lee, Jin-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.247-250
    • /
    • 2000
  • Extracellular polysaccharide was produced by Pseudomonas elodea ATCC 31461 under aerobic condition. Nitrogen sources in medium affected cell growth and production of exopolymer. Ammonium nitrate limitation was found to be essential for higher production of exopolymer. Conversion rate of exopolymer from glucose under ammonium nitrate limitation was about 5 times higher than with ammonium nitrate.

  • PDF

2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp (무전극 램프 점등용 2.5MHz급 ZVS 인버터 개발에 관한 연구)

  • 박동현;김희준;조기연;계문호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.261-265
    • /
    • 1997
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes th driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks (스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구)

  • 박기호;이기우;노승용;이석호;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

Surgery First Approach in Orthognathic Surgery : Indication and limitation (임상가를 위한 특집 4 - 턱교정수술에서 선수술접근 :적응증과 한계)

  • Hwang, Dae-Seok
    • The Journal of the Korean dental association
    • /
    • v.50 no.11
    • /
    • pp.682-688
    • /
    • 2012
  • Surgery first approach in orthognathic surgery is to proceed the orthognathic surgery without preoperative orthodontic treatment. This approach has many advantages, which include a shorter total treatment period, a high level of patient satisfaction due to immediate post-surgical facial improvement, easy postoperative orthodontic treatment due to early normalization of skeletal muscle, and the rapid tooth movement reflecting the regional accelerated phenomenon. However instability due to transient occlusal interference after surgery make worse of long-term skeletal stability. Especially increasing of vertical occlusion caused by interference of interbicupid and molar happen postsurgical skeletal change. Until now, there is no common consensus about treatment protocol of surgery first approach in orthognathic surgery. The purpose of this paper is to introduce our treatment protocol of the surgery first approach and to evaluate indication and limitation with case analysis.

Perceptual Characteristics of Korean Vowels Distorted by the Frequency Band Limitation (주파수 대역 제한에 의한 한국어 모음의 지각 특성 분석)

  • Kim, YeonWhoa;Choi, DaeLim;Lee, Sook-Hyang;Lee, YongJu
    • Phonetics and Speech Sciences
    • /
    • v.6 no.1
    • /
    • pp.85-93
    • /
    • 2014
  • This paper investigated the effects of frequency band limitation on perceptual characteristics of Korean vowels. Monosyllabic speech (144 syllables of CV type, 56 syllables of VC type, 8 syllables of V type) produced by two announcers were low- and high-pass filtered with cutoff frequencies ranging from 300 to 5000 Hz. Six listeners with normal hearing performed perception tests by types of filter and cutoff frequencies. We reported phoneme recognition rates and types of perception error of band-limited Korean vowels to examine how frequency distortion in the process of speech transmission affect listener's perception.

Prediction of Continuous Reactors Performance Based on Batch Reactor Deactivation Kinetics Data of Immobilized Lipase

  • Murty, V.Ramachandra;Bhat, Jayadev;Muniswaran, P.K.A.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.4
    • /
    • pp.225-230
    • /
    • 2002
  • Experiments on deactivation kinetics of immobilized lipase enzyme from Candida cyl-indracea were performed in stirred bath reactor using rice bran oil as the substrate and temperature as the deactivation parameter. The data were fitted In first order deactivation model. The effect of temperature on deactivation rate was represented by Arrhenius equation. Theoretical equations were developed based on pseudo-steady state approximation and Michaelis -Menten rate expression to predict the time course of conversion due to enzyme deactivation and apparent half-life of the immobilized enzyme activity in PFR and CSTH under constant feed rate polity for no diffusion limitation and diffusion limitation of first order. Stability of enzyme in these continuous reactors was predicted and factors affecting the stability were analyzed.

A Study on the Barrier of Intrinsic Safety Type (본질안전방폭용 BARRIER에 관한 연구)

  • 오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.938-945
    • /
    • 2004
  • Intrinsic safety is generally considered the safest method of operating electrical instrumention in potentially explosive atmospheres. The method of intrinsic safety limits the energy passing into the hazardus area. The energy limitation is provided by the use of safety barriers which are mounted in the safe area. Because of the energy limitation, regardless of the fault in the hazardous area, sufficient energy cannot be released to ignite the explosive atmosphere. The following industries are known to have hazardous locations: chemical. munitions, petrochemical, auto(paint spray booths), grain, waste water, printing, distillers, pharmaceutical. breweries, cosmetics, and utilities. In this paper, a isolator type barrier for ship(LNG, LPG, etc,) and test equipment confidence are proposed. The test equipments are designed for mechanical electrical life time test and vibration. All of test results satisfy the goal and the studied barrier shows the improved confidence.