• 제목/요약/키워드: lightning surge current

검색결과 119건 처리시간 0.029초

매설지선 접지임피던스의 주파수 의존성 (Frequency Dependance of Ground Impedances of the Counterpoises)

  • 최영철;최종혁;김동규;이규선;양순만;이수봉;이복희;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1489_1490
    • /
    • 2009
  • Ground impedance is changed according to frequency of the current injected into the grounding system. Because the lightning surge gives a broad frequency spectrum from some ten Hz to a few MHz, frequency dependance of ground impedance must be evaluated. In this paper, we have constructed 10m, 30m, 50m counterpoise and evaluated frequency dependance of ground impedance. Also we have evaluated frequency dependance of ground impedance according to current injection point. As a result, long counterpoises have low ground resistance, but ground impedances of those are significantly increased in the range of high frequency. In the case that currents are injected into the center of counterpoise, the ground impedance is most lower than any other injection point. Also, additory ground rod of 1.8m long affect ground impedance decrease.

  • PDF

초고압용 피뢰기 산화아연소자의 전기적 특성 평가 (Evaluation of Electrical Characteristics of Metal Oxide Varistors for Surge Arresters)

  • 조한구;윤한수;김석수;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • This paper presents the electrical characteristics of metal oxide varistors for lightning surge arresters. ZnO varistors were fabricated with typical ceramic production methods and two types of varistors were also prepared to be compared. The nominal discharge current and line discharge class of those varistors are $10kA(8/20{\mu}s)$ and class 3, respectively. The diameter of varistors manufactured and prepared were in the range of 61.6~65.0mm and the thickness of those were in the range of 27~42.52mm. The reference and residual voltage were tested and reference and residual voltage per 1mm and the ratio of reference and residual voltage were calculated. The reference voltage per 1mm of varistors manufactured was about 175V/mm but that of A's and B's varistors was nearly 200V/mm. The residual voltage exhibited the same trends as the reference voltage, so the reference and residual voltage per 1mm of domestic varistors should be increased. According to the results of tests, it is thought that if the reference and residual voltage per 1mm were increased to 200V/mm and 330V/mm, domestic ZnO varistors would be possible to apply to the station class arresters in the near future.

  • PDF

직선형 접지전극의 임계길이의 산정 (Computation of Critical Length for Linear Grounding Electrodes)

  • 김기복;이복희;조정현
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.67-74
    • /
    • 2009
  • 뇌전류와 같이 고주파성분을 함유한 서지전류나 전자통신기기의 전자기장해를 유발하는 고주파 이상전류에 대하여 접지전각은 주파수에 의존적인 상당히 복합적인 입피던스의 특성을 보인다. 접지전극의 접지임피던스는 접지전극의 크기를 증가시켜도 낮아지지 않고, 대지의 특성과 주파수 조건에 따라 접지임피던스가 최소값을 보이는 접지전극의 길이가 존재하며, 이 접지전극의 길이를 대지의 특성과 주파수 조건에 대한 임계길이라 정의한다. 본 논문에서는 분포정수회로모델을 이용하여 수직접지전극과 수평접지전극의 임계길이를 산정하였으며, 실험결과와의 비교를 통해 타당성을 확인하였다.

접지전극의 형상에 따른 과도접지임피던스 (Transient Ground Impedances According to Shapes of Grounding Electrodes)

  • 이복희;이수봉;이태형;정현욱;정동철
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.65-70
    • /
    • 2006
  • 본 논문은 임펄스전류에 따른 접지시스템의 과도 특성에 관한 것으로 임펄스 전류를 심매설 봉상 접지전극과 그리드 접지전극에 인가하였을 때 나타나는 과도접지임피던스를 조사하였다. 과도접지임피던스는 인가전류의 상승시간과 접지전극의 크기 및 형태에 강하게 의존하며, 접지전극의 인덕턴스는 짧은 시간 영역에서 접지시스템의 과도 접지임피던스에 크게 영향을 미치는 것으로 나타났다. 또한 심매설 봉상접지전극은 짧은 시간영역에서 과도접지임피던스를 줄이는데 효과적이었다.

탄소접지극이 병설된 접지그리드의 접지임피던스의 해석 (Analysis of the Ground Impedance of Ground Grids Combined with the Carbon Ground Electrodes)

  • 이복희;엄상현;김유하;이강수;전병욱;최종혁
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.36-42
    • /
    • 2013
  • This paper deals with the frequency-dependent ground impedance of ground grids combined with the carbon ground electrodes. Ground grids are generally valid for multipurpose grounding systems as well as lightning protection systems. The carbon ground electrodes may be supplementarily used to reduce the high frequency ground impedance and to improve the transient response to surge currents. The frequency-dependent ground impedances of ground grids combined with or without the carbon ground electrodes were measured and their simulations with due regard to frequency-dependent soil resistivity were implemented by using EMTP program and Matlab modeling. As a consequence, the ground impedance of ground grids combined with the carbon ground electrodes is significantly reduced when the test current is injected at the terminal of the carbon ground electrode. The measured and simulated data for the test ground grids fairly agree with each other. It was found that the proposed method of simulating the frequency-dependent ground impedance is distinguished. The simulation techniques of predicting accurately the ground impedances without actual measurements can be used in the design of grounding systems based on ground grids and the carbon ground electrodes.

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;송재용;길경석;권장우
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.133-143
    • /
    • 2001
  • 본 논문은 직각파 및 뇌충격진류에 대한 봉상접지각의 과도임피던스 특성을 정상접지지항과 비교.분석하였다. 접지계는 단일$(\Psi10[mm], 1[m])$과 5[m]의 간격을 두고 서로 연접한 3연접 봉상접지극으로 구성하였으며, 과도 임피던스 특성을 분석하기 위하여 상승시간 30[ns], 펄스폭 $20[\mus]$의 직각파전류 발생장치를 설계 제작하였다. 실제 낙뢰에 의한 접지임피던스의 변화를 관찰하기 위하여, 국제규격 ANSI/IEEE, IEC에 규정되어 있는 뇌충격전류를 인가하여 이에 따른 특성변화를 측정.분석하였다. 접지계로 유입된 과도전류는 접지계의 전위를 상승시키며, 이 때의 전위상승과 유입전류의 비로써 접지임피던스를 산출하며, 뇌격전류에 대한 경제적인 보호 수준을 평가.예측하기 위하여 임피던스 파라미터를 측정결과로부터 산출하였다. 또한 연접에 따른 접지임피던스의 감소와 접지리드선이 미치는 영향도 분석하였다.

  • PDF

전기적 과도현상으로부터 통신망의 보호대책 (The Protection methods of Telecommunication Network from Electrical Transient Phenomena)

  • 최만호;김현덕;김병철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.693-696
    • /
    • 2005
  • 국내의 통신망은 효율적인 유지보수를 위하여 도로를 따라 기반시설이 구축되고 있기 때문에 전력망과 통신망의 교차와 병행이 가속화되고 있다. 전력망은 전력유도를 발생시킬 뿐만 아니라, 낙뢰와 같은 전기적 과도현상으로부터 그 자체가 전송매체로 되기 때문에 전력망 지중 접지체와 통신망 지중 접지체간을 통하여 낙뢰서지 및 지락선 과도 현상이 통신망에 유도되어 악영향을 초래한다. 본 연구에서는 통신망의 보호대책으로 지중접지체간의 이격거리를 통한 귀로전류의 차단과 양쪽 단자의 유휴심선을 접지하여 전력유도전압을 차폐하는 방법이 우수한 효과를 나타냄을 확인 할 수 있었다.

  • PDF

접지그리드의 접지임피던스의 주파수 의존성 (Frequency Dependence of Impedance of the Grounding Grid)

  • 이복희;이동문;엄주홍;김교운
    • 조명전기설비학회논문지
    • /
    • 제17권5호
    • /
    • pp.22-28
    • /
    • 2003
  • 본 논문에서는 접지임피던스의 주파수 의존성에 대하여 기술하였다. 사용중인 접지시스템의 과도응답특성을 평가기법을 제안하기 위하여 가변주파수 인버터와 대역통과 필터를 사용하여 인가전류의 주파수를 가변시키면서 접지임피던스를 측정하였다. 20[Hz]∼2.1[kHz] 범위의 주파수에서 접지임피던스의 크기와 위상을 분석한 결과 접지임피던스는 인가전류의 주파수가 증가함에 따라 증가하는 경향을 나타내었다. 22.9[kV] 변전실 접지시스템에서 인가전류의 주파수가 2[kHz]일 때 측정한 접지임피던스는60[Hz]일 때 보다 거의 3배 정도 증가하였다. 접지시스템의 주파수 의존성은 접지도체의 인덕턴스에 의해 나타나는 리액턴스 성분에 기인하는 것으로 나타났다. 따라서 뇌서지 보호용 접지시스템에서는 인덕턴스를 줄이는 방향으로 접지그리드의 형태와 규모를 결정하는 것이 필수적이다.

온도변화에 따른 SF6/N2 혼합가스의 임펄스 절연파괴특성 (Impulse breakdown Characteristics in SF6/N2, Gas Mixtures with a Temperature Variation)

  • 이봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.79-86
    • /
    • 2008
  • 본 논문은 온도변화에 따른 $SF_6/N_2$ 혼합가스 중에서 높은 불평등전계의 임펄스절연파괴특성에 대한 실험적인 결과를 기술하였다. 온도범위는 $-25{\sim}25[^{\circ}C]$로 정하여 실험을 수행하였다. 임펄스 전구방전진전은 방전전류와 방전 광신호의 측정에 의해 분석되었다. 결과로써, 절연파괴전압은 정극성보다 부각성에서 온도변화에 대한 의존성이 강하게 나타났다. 온도가 상승함에 따라 부극성에서의 리더진전 스텝핑시간이 정극성보다 더 길게 나타났다. 본 연구 결과는 뇌서지에 대하여 우수한 성능을 가지는 가스절연선로의 설계에 유용한 정보가 될 것이다.