• Title/Summary/Keyword: lighting fixture

Search Result 75, Processing Time 0.02 seconds

A Study on Energy Savings When replacing Performing Halogen Lights with LED Lights in Seoul Community Hall (서울시 구민회관 공연용 할로겐 조명을 LED 조명으로 교체시 에너지 절감에 관한 연구)

  • Lee, Jang-Weon;Kwon, Hyeok-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.213-217
    • /
    • 2015
  • Seoul has 25 areas of City Hall, the ward office has been operating theater at least 1 in maximum 4-5 locations to various sized places. The purpose of theater has been used for a variety of purposes to typical performances of Drama and Musicals, School play, Lecture. This points to a Variety of ideas for use, when replacing an exsting halogen luminaires, appropriate LED luminaires, Learn more if there is any advantage in terms of the energy saving part. it will be applied to the value for the energy saving to ward office hall of the actual targets. In case replacement in existing halogen luminaires to LED luminaires, to energy savings of about 80% appear around. Get the advantages of the various functional properties a device chip of the LED itself, Forward will be referred to as easy to replace the halogen luminaires and LED luminaires.

Analysis of Heat Dissipation Characteristics for Standard 25 [W] LED Module of Korea Expressway Corporation: Using CFD Analysis (CFD 해석을 이용한 한국도로공사 표준 25 [W] LED 모듈의 방열 특성 분석)

  • Lee, Se-Il;Her, In-Sung;Lee, A-Ram;Jung, Min-Joo;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.541-546
    • /
    • 2014
  • Korea Expressway Corporation established standard of LED lighting fixture in Dec. 2013. To raise compatibility, the standard requires a fixed form and it is applied to street lights and tunnel lights, etc. Because streetlight has different circumstance condition from tunnel light that is down light and exposed to constant wind velocity over height of 8 meters, in case of LED module which has the same shape, characteristic of radiant heat can be different. In this paper, we designed 25 [W] LED Module that is designated by standard of Korea Expressway Corporation and analyzed characteristics of radiant heat about natural convection and forced convection. It is dropped 10.12[$^{\circ}C$] that max temperature is decreased by increasing 20 mm of bended height of heatsink at the condition of natural convection. Radiant heat characteristic of bended height 35 mm became 78.08[$^{\circ}C$] at the condition of natural convection, 55.30[$^{\circ}C$] at the condition of forced convection so that 22.78[$^{\circ}C$] is decreased that is 29.1[%] decrease. Bended height 55mm became 67.96[$^{\circ}C$] at the condition of natural convection, 48.04[$^{\circ}C$] at the condition of forced convection so that 19.92[$^{\circ}C$] is decreased that is 29.3% decrease.

A Study on the Characteristics of Interior Elements of Frank Lloyd Wright's Residential Design (F. L. Wright의 주택특성과 실내디자인 요소분석에 관한 연구)

  • 서수경
    • Korean Institute of Interior Design Journal
    • /
    • no.5
    • /
    • pp.45-52
    • /
    • 1995
  • Frank Lloyd Wright, a master of the 20th Century Ar-chitecture, contributed tremendously in creating a wholly new form of American architecture called Prairie Style. His idea behind the development of the building structur-al system, organic relationships between inner and outer space, horizontal vertical lines, and idea of extending and expanding interior spaces came from nature. He had completed over 390 projects throughout his life and 90% of those projects were residential design. The most typical characteristic shared by many of his residential design was that each design element, whether it is functional or aesthetical, has close relationship to or-ganic nature, human scale, theoretical floor plants, and maximum emphasis on horizontal lines in respect to na-ture. His concept of "flow of spaces" reformed common the-ory of room next to room in a enclosed space. His sense of "wall" was no longer the side of a box. Careful selec-tion of finishing materials, colors, and natural images en-hance the design as well. F.L. Wright was an artist, designer, and architect who believed the exterior space should have direct relationship to the interior space. His architectural philosophy was not only to design exterior of architecture but also to ful-fill his space through the careful development of interior elements such as furniture, and lighting fixture. Even the patterns for leaded glass windows were designed to have unified appearance from outside to inside of the house. The objective of this study was to analyze floor plans, spatial organizations, and interior design elements of the houses which represent the best of F.L. Wright's design principles and philosophy behind Prairie Style. The meth-od used to collect informations for this study was based on books, articles, journals, and actual site visits. actual site visits.

  • PDF

Influence Factors on Health of Dental Hygienist by Dental Office's Indoor Air Quality (치과위생사의 병원실내공기질에 의한 건강영향요인)

  • Park, Myung-Suk;Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • This survey was compared and analyzed about the primary factor that dental office's working environment effect on physical subjective symptom and based on self-filling survey, 656 dental hygienists on July through August 2006, and analyzed using descriptive statics, ANOVA and Multiple Regression Analysis. The result of satisfaction degree of hospital working environment was pretty low about office air condition. Most people have complained that office's air quality makes it difficult to their work and mentioned that they were sore and dull all over the back, shoulder, and neck. The odor is major factor to be satisfied with office environment. Proper ventilates the way open the window more often was essential to maintain fresh indoor air quality and keep the extraction materials by separator and sealing tightly for remove the odor. Other factors were temperature, lighting fixture, ventilation facilities, and freshness of air. Dental hygienist was unsatisfied with hospital air condition and this polluted air condition was the cause of physical subjective symptom in work place. Furthermore, this research would be applied for improvement of working environment by decreasing of indoor air pollution.

  • PDF

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.