• Title/Summary/Keyword: lighting estimation

Search Result 87, Processing Time 0.048 seconds

Developement of Lighting Energy Estimation Nomograph by using Daylight (자연채광 이용에 따른 조명에너지 평가용 노모그래프의 개발에 관한 연구)

  • 정유근;김정태
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.28-34
    • /
    • 1990
  • Lighting is one of the largest energy, integrated lighting system with daylight and artificial lighting has been suggested. In such system, perimeter zone can be illuminated by daylighting and the deep area of room by artificial lighting. So, the study is to develope estimation nomograph of lighting energy by turnning-off depth and lighting control systems during daytime. For the purpose, energy nomograph has been developed to apply to side-lit office guilding and the use and limitation of the nomograph has been discussed.

  • PDF

A study on the Assessment of Standard Wages for Constructing Luminaries for Landscope Lighting (경관조명기구의 설치에 대한 기준노임 산정에 관한 연구)

  • Yoo, Dong-Gil;Lee, Bok-Hee;Lee, Sok-Yeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.169-172
    • /
    • 2008
  • Recently, landscape lighting is more and more installing in many places such as park, cultural heritages, large-scale structures, bridges, apartment, and so on. However, there is no the government-set official estimation for standard wages constructing luminaries for landscape lighting. The cost of construction is estimated based on the standard wages of related-similar installations such as internal lighting fixtures or the designer's subjective decision. Sometimes, it is overestimated or underestimated. In this paper, the fundamental process for estimating the standard wages constructing luminaries for landscape lighting is studied. The estimation method of standard wages constructing lighting fixtures was examined on the basis of the type and capacities of luminaries, installation places, type and shapes of installation auxiliary materials, worker's skill, and etc. As a result, some results obtained in this work were significantly, different with the standard wages for internal electric wiring published by Korea Electric Association. In the future, to improve the accuracy of the estimation of the standard wages for constructing luminaries for landscope lighting, detailed factors related to the installation condition and dimensions and types of luminaries should be considered.

  • PDF

Evaluation of Discomfort Glare Indices in Office Lighting (사무실 조명에서의 Discomfort Glare 계산법 적용 및 평가)

  • Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.13-21
    • /
    • 2002
  • In the interior lighting, usually we refer to TAL and general lighting. The last one is that we generally adopt it in the interior lighting conditions. Here, glare is most important factor of them, especially in working place using VDT. Reference or development of estimation on glare has been studied in CIE, IESNA etc. and these of glare regulations now are applied differently in the interior lighting design or estimation on glare. But we have no glare regulation in detail, of course except G classification, which has limit of itself, so in my case it is impossible to apply in the interior lighting. On this paper, with some of main glare regulations in the world and our conditions in the interior lighting which are selected carefully, in an actual state it has been estimated So, it intended to blow which one is most suitable or what factors are considered of them, also show glare index which are appropriate to our interior lighting.

Parameter estimation of the Diffusion Model for Demand Side Management Monitoring System (DSM Monitoring을 위한 확산 모델의 계수 추정)

  • Choi, Cheong-Hun;Jeong, Hyun-Su;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1073-1075
    • /
    • 1998
  • This paper presents the method of parameter estimation of diffusion model for monitoring Demand-Side Management Program. Bass diffusion model was applied in this paper, which has different values according to parameters ; coefficients of innovation, imitation and potential adopters. Though it is very important to estimate three parameter, there are no empirical results in practice. Thus, this paper presents the method of parameter estimation in case of few data with constraints to reduce the possibility of bad estimation. The constraints are empirical results or expert's decision. Case studies show the diffusion curves of high-efficient lighting and also forecasting of the peak value for power demand considering diffusion of high-efficient lighting, the feedback and least-square parameter estimation method used in this paper enable us to evaluate the status and forecasting of the effect of DSM program.

  • PDF

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

CONTROL ON PLANT FACTORY IN OPTICAL RADIANT CONDITION ACCORDING TO THE MARKET ECONOMICS

  • Akamine, T.;Murase, H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.586-592
    • /
    • 2000
  • There is currently no satisfactory way to optimize supplemental lighting in a greenhouse-type plant factory especially concerning plant production. In a commercial plant factory, we got outside radiation data, inside radiation data and lamp running data. They have a correlation, but have much disorder. By using regression, tendency between the outside and the inside including supplemental lighting was found. We could estimate the average transmittance of this plant factory. From this estimation, we could admit the amount of inside radiation was supplied as much supplied compared to natural radiation. Then we are trying to investigate of the production amount and the supplemental lighting. Plant factory is environmentally controlled, the temperature and humidity are not actually controlled stable. We propose a design of neural network model could be useful to estimate the profit resulting from the operation of supplemental lighting.

  • PDF

Modeling and Actual Investigation of Roadway Lighting in Jejusi (제주시 도로조명 실태조사 및 모델링)

  • Lee, Sang-Geun;Oh, Seong-Bo;Kim, Duck-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.147-150
    • /
    • 2005
  • Fixed lighting of public ways for both vehicles and pedestrians can create a nighttime environment in which people see comfortably and can quickly and accurately identify objects on the roadway being travelled roadway lighting can improve traffic safety, achieve efficient traffic movement and promote the general use of the facility during darkness. The design of a roadway lighting system involves consideration of visibility, economics, esthetics, safety and environmental conditions. This paper describe estimation of horizontal illuminance by actual measurement at main streets in Jejusi. We try to evaluate Jejusi Roadway Lighting Conditions for modeling by computer simulation.

  • PDF

Modeling and Actual Investigation of Roadway Lighting in Jejusi (제주시 도로조명 실태조사 및 모델링)

  • Oh, Seong-Bo;Kim, Eel-Hwan;Lee, Sang-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.1-5
    • /
    • 2006
  • Fixed lighting of public ways for both drivers and pedestrians can create a nighttime environment in which people can see comfortably and can quickly and accurately identify objects on the roadway being travelled. Roadway lighting can improve traffic safety, achieve efficient traffic movement and promote the general use of the facility during darkness. The design of a roadway lighting system involves consideration of visibility, economics, esthetics, safety and environmental conditions. This paper shows estimation of horizontal illuminance and uniformity ratio by actual measurement of roadway lighting at main streets in Jejusi and evaluation of Jejusi roadway lighting conditions for modeling by computer simulation.

Maximum Current Estimation Method for the Backup of Current Sensor Faults

  • Kim, Jae-Yeon;Park, Si-Hyun;Suh, Young-Suk
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • This paper presents a new method for controlling the current of lighting LEDs without current sensors. This method can be used as backup against LED current sensor faults. LED lighting requires a circuit with a constant current in order to maintain the same brightness when the ambient temperature changes. Therefore, we propose a new current estimation method to provide backup in case of current sensor faults based on the calculation of the inductor current. In the fabricated circuit, the average current changes from 144.03 mA to 155.97 mA when the ambient temperature changes from 0℃ to 60℃. The application of this study can enable the fabrication of a driving IC for LEDs in the form of a single chip without sensing resistors. This is expected to reduce the complexity of the peripheral circuit and enable precise feedback control.