• Title/Summary/Keyword: light therapy

Search Result 506, Processing Time 0.03 seconds

Development of Indocyanine Green and 5-Aminolevulinic Acid Detection System for Surgical Microscope (수술현미경용 다중형광 관측 시스템 연구)

  • Kim, Hong Rae;Lee, Hyun Min;Yoon, Woong Bae;Kim, Young Jae;Kim, Seok Ki;Yoo, Heon;Joo, Jae Young;Kim, Kwang Gi;Lee, Seung-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • Indocyanine green(ICG) and 5-aminolevulinic acid(5-ALA) have been widely used to mark blood vessels or tumors. However, fluorescent dye detection systems were designed to use one type of dyes only. In this study, we proposed a detection system capable of detecting Indocyanine green and 5-aminolevulinic acid. Multiple filters and light sources are integrated into a single system. In this study, we performed analysis of fluorescent dyes and configured a detection system. During the analysis, it was found that Indocyanine green and 5-aminolevulinic acid have the maximum intensity at $40{\mu}M$. We designed light source for fluorescent dyes and conducted compatibility test using a commercial surgical microscope. The fluorescent dye detection system was configured based on the experimental results. The developed system successfully detects Indocyanine green and 5-aminolevulinic acid. Therefore, more efficient surgical operations can be achieved using both fluorescent dyes at the same time. We expect that the developed system can increase the survival rate of patients.

A Case of Spindle Cell Hemangioendothelioma Involving the Lung, Mediastinum and Brain (폐, 종격동 및 뇌를 침범한 방추세포형 혈관내피종 1예)

  • Kim, Hwan-Tae;Kim, In-Ho;Lee, Bong-Choon;Kang, Chang-Il;Yoon, Hye-Kyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.301-307
    • /
    • 1993
  • Intravascular bronchioloalveolar tumor is now recognized as a pulmonary form of hemangioendothelioma(HE). HE is an unusual tumor of adult life which is characterized by proliferation of an "epithelioid" or "spindle" endothelial cell. In the lung it usually presents as multiple bilateral slowly growing nodules less than 2 cm in diameter. The aetiology and pathogenesis of this disease are unknown. Spindle cell HE occurs at any age, but approximately one half of patient are 25 years of age or younger and males are affected twice more frequently than females. On light microscopic examination, the tumor show mild cellular atypia, nearly absent mitoses and electron-microscopic studies reveal evidence of endothelial cell differentiation. Intracytoplasmic localization of Factor VIII-related antigen is demonstrated on immunohistochemical study, which confirmed the endothelial origin of the tumor. No effective therapy is yet known for HE, but survival of this tumor can be quite long. However, one half of the patient have died, usually of progressive pulmonary insufficiency. This 19-yr-old male complained of Rt. chest pain and intermittent hemoptysis. Simple chest film and chest CT scan showed the Rt. pleural effusion, variable sized bilateral pulmonary nodules, irregular large heterogenous tumor with well enhancement and extensive necrosis in the anterior mediastinum. The mediastinal mass was biopsied and diagnosed as spindle cell HE by light microscopic finding and immunohistochemical studies.

  • PDF

Keratinocyte Proliferation in Aged Rat Skin by High Voltage Pulsed Current Stimulation

  • Lee Jae-Hyoung;Lee Jong-Sook;Kil Eyn-Young
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.361-366
    • /
    • 2004
  • The purpose of this study was to determine the effect of high voltage pulsed current (HVPC) stimulation on proliferative activities of basal keratinocytes by measured nucleolar organizer region (NOR) expression and thickness of spinous layer in aged rat skin. Fifty-one weeks old twelve male Sprague-Dawley rats (300∼350g) were divided into control and HVPC stimulation groups. Each animal's hair on the back were removed. The HVPC stimulation group received an negative monophasic twin peak pulsed current stimulation with 50 V, while the control group was given the same treatment without electricity. The rats were sacrificed after 3 weeks. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with hematoxyline-eosin and silver nitrate. The thickness of basal to granular layer of the epidennis were measured using a light microscope and computerized image analysis system. The number of argyrophilic nucleolar organizer region (AgNOR) were counted using a light microscope and computerized image analysis system and calculated as the mean number of AgNOR per nucleus in the basal keratinocyte. By using a Student's t-test, an increase in the thickness of basal-spinous layer (P<0.001) of epidermis can be observed in HVPC stimulation rats as compared with the control rats, whereas the thickness of the granular layer is not affected. A Student's t-test showed a significantly higher mean NOR number per nucleus of the basal keratinocyte in the HVPC stimulation rats than control rats (P<0.001). There was significantly positive correlation between the NOR number and the thickness of basal-spinous layer (r=0.80, P<0.05). These results suggest that the HVPC stimulation may increase the thickness of spinous layer in the epidennis due to increased proliferative activities of basal keratinocytes in epidennis in aged rat skin.

  • PDF

Photo Epilation with Intense Pulsed Light for Thinning of Anterior Hairline after Hairline Correction Surgery in East Asians

  • Park, Jae Hyun;Lee, Seung Yong;You, Seung Hyun;Kim, Na Rae
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.157-161
    • /
    • 2017
  • Background Thin hairs are critical to achieve natural result in female hairline correction surgery. However, there are few studies on the usefulness of hair thinning by intense pulsed light (IPL) after hairline correction surgery in East Asian females. Methods Hair thinning using IPL was performed in 54 women who had complained about thick hairs along the frontal hairline after hairline correction surgery. Patient mean age was 31.2 years old and patients were an average of 2.1 years post-hairline correction surgery. Initial treatment used 10 J, while second and third sessions were conducted with 10 to 15 J according to responsiveness to treatment. Results Mean thickness of individual hairs assessed before the procedure was $78.86{\mu}m$. The mean number of procedures was 1.6 per patient. Forty of 54 subjects (74%) achieved satisfactory hair thinning with only one procedure from 78.01 to $66.14{\mu}m$ after treatment. The measured thickness was $66.43{\mu}m$ at the end of the first year in patients who were satisfied after one procedure. Thirteen cases achieved satisfactory hair thinning after two sessions. Mean thickness was $74.44{\mu}m$ and $67.51{\mu}m$, before and after the second session. One case required a third session with 15J, thinning from 89.00 to $66.50{\mu}m$. Conclusions Hair thinning by IPL is a very useful method to provide a natural look after hairline correction surgery in East Asians, who have naturally thick hair.

Effects of Modified Low-Dye Taping on Stroke Patients with an Excessive Pronated Foot (과도하게 엎침된 발을 가진 뇌졸중 환자에게 적용된 수정 발바닥활 지지 테이핑의 효과)

  • Kim, Hyun-Wook;Ryu, Young-Uk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.2
    • /
    • pp.69-74
    • /
    • 2018
  • PURPOSE: Stroke patients may develop an over-pronated foot, resulting in a lower medial longitudinal arch. This can lead to a structural change of the foot due to deformation of the musculoskeletal system. The purpose of this study was to examine the effects of modified low-dye taping on stroke patients with an excessively pronated foot. The effect of the taping on the foot after light daily activity was also examined. METHODS: The subjects consisted of 21 stroke patients with an excessively pronated foot, as measured by the navicular drop test. First, their navicular heights were measured at a relaxed standing position (measure 1) and while standing in the subtalar neutral position (measure 2). Modified low-dye taping was applied to each subject's affected foot and the navicular height was then measured for the standing posture (measure 3). Finally, each subject walked around for 10 minutes and the navicular height was measured again (measure 4). RESULTS: Statistical analyses showed that the navicular height value at the relaxed standing position (measure 1) was significantly lower than for the other 3 measurements. That is, the modified low-dye taping was effective in maintaining a subtalar neutral position, even after a 10-minute walk, for stroke patients with an excessively pronated foot. CONCLUSION: The results suggest that modified low-dye taping applied to stroke patients with an excessively pronated foot could be an effective way to place the subtalar joint in a neutral position, and that its effect can be sustained for light daily activities.

Effects of Abdominal Drawing-in Maneuver With Light Load at Sitting on Transverse Abdominis Contraction in Participants With and Without Low Back Pain (앉은 자세에서 가벼운 부하를 들고 수행하는 복부드로잉 운동이 요통대상자와 건강인의 배가로근 수축에 미치는 영향)

  • Jong-Im Won
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.243-253
    • /
    • 2023
  • Purpose: This study aimed to investigate the effects of an abdominal drawing-in maneuver (ADIM) with a light load while sitting on transverse abdominis contraction in subjects with and without low back pain. Methods: In this study, 20 participants with chronic low back pain and 20 controls participated. Ultrasonography was used to assess the thickness of the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) muscles. Muscle thickness was measured at rest and during ADIM in three different sitting postures: (1) just sitting, (2) sitting loaded position (holding a 1 or 2 kg dumbbell in each hand), and (3) sitting loaded shoulder flexion position (holding a 1 or 2 kg dumbbell in each hand). Results: The contraction ratio (CR) and preferential activation ratio (PAR) of the TrA during ADIM had no significant interactional effect between the group and the sitting postures. However, the CR and PRA of the TrA during the ADIM showed significant differences among the three different sitting postures. The CR of the TrA during the ADIM in the sitting loaded shoulder flexion position was significantly increased compared to that in the sitting position (p<0.05). Moreover, the PRA of the TrA muscle during ADIM in sitting loaded and sitting loaded shoulder flexion positions was significantly higher than that in the sitting position (p<0.05). Conclusion: The findings suggest that ADIM in the sitting-loaded shoulder flexion position should be implemented to facilitate TrA activity.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Exercise Prescription and Dietary Modification for Prevention and Treatment of Chronic Degenerative Disease I. On Obesity and Diabetes (성인병의 예방과 치료를 위한 영양과 운동처방 I. 비만과 당뇨병에 미치는 영향)

  • 백영호;전병학
    • Journal of Life Science
    • /
    • v.9 no.2
    • /
    • pp.222-230
    • /
    • 1999
  • Obesity is an excessive increased state of total body fat, and diabetes is a disease lack or defect of insulin which controls blood sugar. The reason of obesity and diabetes are history, lack of exercise, overeating, stress and so forth. The principle of dietary modification in the obesity and diabetes are controling total calorie control, and taking orderly meals, and restricting high calorie food. General exercise guidance will recommend to take precedence over the medical diagnosis, case history test before the exercise begins, and the beginning of exercise. It start with light excercise, and gradually enhance intensity The fundamental and effective cure of obesity and diabetes is aerobic exercise (as jogging, swimming, playing tennis, aerobic dancing). It is reasonable for exercise intensity to be 60~80$\%$ HRmax(50~70$\%$ $Vo_2$ max) and for the duration to be 15~60minutes a day and frequency to be 3~6 times a week. Especially the exercise intensity may be changeable according to the, pattern of diabetes. The snack that contains carbohydrate during exercise will discontinue the exercise when insulin activity is reached on high peak, and it is a proper way taking 15~20g's carbohydrate contained food against possibility of the low blood sugar occurance after exercise, At last, it is much effective the exercise therapy is combined with the diet therapy for best diabetes treatment.

  • PDF

The Difference of Grip Strength, Upper Limb Dexterity, and Hand Function according to Light Touch and Thermal Sensory Stimulus (촉각과 온각 자극에 따른 악력, 상지 기민성, 그리고 손 기능의 차이)

  • Rhee, Hyeon-Sook;Kim, Sung-Joong;Yu, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2644-2651
    • /
    • 2011
  • The purpose of this study was to investigate difference between grip strength, upper limb dexterity, and hand function according to touch and heat sensory stimulus. Forty healthy men were recruited. After obtaining subjects characteristics, examined grip strength, upper limb dexterity, and hand function, then we made touch sensory input using soft brush and tried the test again. Next day, we made thermal input using hot pack and did retest, too. The result showed significant differences appeared on every variable in grip strength and upper limb dexterity test (p<.001), and significant differences appeared on every variable except lifting small objects in hand function (p<.01). In conclusion, sensory input is to increase grip strength, upper limb dexterity, and hand function. The thermal sensory input has a tendency to increase grip strength, upper limb dexterity, and hand function than that of touch sensory input in effect of stimulus classification. The application of proper stimulus helps to facilitate upper limb and hand function in rehabilitation and in industrial field. So it is necessary to try more tests of frequency and intensity of stimulus.

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF