• Title/Summary/Keyword: light source modulation

Search Result 72, Processing Time 0.024 seconds

A Study on the WDM-PON System Using Shared Laser and LED Light Sources (공유 레이저 광원 및 LED 광원을 이용한 WDM-PON 시스템에 관한 연구)

  • 이용기;이영호;박봉근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.573-578
    • /
    • 2000
  • This paper presents a noble optical access system using shared laser and LED light sources, which is based on WDM-PON technologies. This system adopts an external modulation of the shared laser sources for high-speed downstream and a direct modulation of the LED sources for low-speed upstream. To split or combine the transmission channels, AWG(Arrayed Wave-guide Grating) devices are used in the optical cable section. The proposed system is attractive for low cost implementation. The laser light sources can share the optical carriers in the downstream scheme. Also, in upstream, the LED sources can afford to make simple of the circuits for controlling light source and of standardization for ONU(Optical Network Unit). The feasibility of the proposed system is demonstrated by several experiments. Our results show that the system operates well at 2.SGbps for downstream and up to 622.08Mbps for upstream.

  • PDF

Performance analysis of the visible light communication in seawater channel (해수채널 환경에서 가시광 통신 성능 해석)

  • Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.527-532
    • /
    • 2013
  • The wireless visible light communication technology has received great attention for high-data rate services in the room and underwater. However, performance of a visible light seawater link is limited by multiple constraints from the current light source and detector technology, and underwater channel conditions. In this paper, performance of the line of sight underwater link was analyzed in terms of signal to noise ratio and bit error rate of the detector. Roles of different parameters such as data rate, transmission distance, and attenuation coefficient, are studied. Through the modeling and simulation of the OOK and L-PPM modulation technologies for undersea environment application, the advantages and limitations are described in detail.

A Study on Strobe Control over LED Lighting System for Machine Vision (머신비전을 위한 LED 조명시스템의 스트로브 제어 구동에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.121-125
    • /
    • 2021
  • The machine vision technology has been widely used in the industrialized nations like the United States, Japan, and EU in the various industries from the late 1980s. Machine vision inspection system mainly consists of a camera, optics, illumination and an image acquisition system. Optimization of the illumination light source is very important. This paper shows a comparison between Pulse Width Modulation (PWM) control and strobe control in driving LED lighting system for machine vision. PWM control method has problems such as a temperature rising of LED and a flickering in image measurement for inspection. In contrast, the proposed strobe control method can suppress the temperature of LED light source below 40℃. Also, it can remove the flickering problem through a synchronization between a frame grabber and a camera shutter. Finally, the strobe control method was shown to extract clearer images with a high precision compared to PWM control method.

Optical Property Measurements of Optical Phantoms and Honan Tissues Using Frequency-Domain Diffuse Optical Tomography (주파수 영역 확산광 단층촬영 장치를 이용한 광 팬텀 및 인체조직의 광 계수 측정)

  • Ho, Dong-Su;Kwon, Ki-Woon;Eom, Gi-Yun;Lee, Seung-Duk;Kim, Beop-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.229-234
    • /
    • 2007
  • Diffuse optical tomography (DOT) is a relatively new medical imaging modality which uses near infrared light to image large-sized tissues noninvasively. We constructed a frequency-domain DOT system to measure the optical properties of optical phantoms and human tissues. The FD-DOT uses the intensity-modulated infrared light source that illuminates the biological tissues. The phase shift and modulation changes at each detector site are separately processed to measure the optical properties. The absorption and scattering coefficients are separately estimated using inverse algorithms.

A flat thin display with RF electron generation

  • Dijk, R. Van;Vissenberg, M.C.J.M.;Zwart, S.T. De
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.927-930
    • /
    • 2004
  • We report on a new type of a flat and thin display with a secondary emission electron source. In this display device electrons are multiplied between two secondary emission plates under a high frequency electric field. This principle has a few important advantages over a field emission display: the emission comes from flat plates, which reduces the life-time problems of ion bombardment of field emitter tips. Furthermore, the electron emission is space charge limited which gives a uniform electron distribution. The electrons are extracted from the source and accelerated to a phosphor screen to generate light. Gray levels are made by pulse width modulation.

  • PDF

The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application (방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가)

  • Shin, Jung-Wook;Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Yul;Kim, Jin-Young;Lee, Gun-Hwan;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

Characteristics of Low-level Light Source for Animal Cell Proliferation (동물 세포 증식을 위한 저출력 광 소스의 특성)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Song, Chang-Hun;Mun, Seong-Pyo;Kim, Tae-Gon;Park, Yong-Pil;Kim, Dae-Young;Kim, Young-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.92-97
    • /
    • 2007
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for both Rat bone marrow and Rat tissue cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow and tissue cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.

MTM MEASUREMENT OF THE LENS ON THE KITSAT-1 EARTH IMAGING SYSTEM (우리별 인공위성의 지상 촬영 장치에 쓰여진 렌즈의 MTF 측정)

  • 류광선;민경욱;유상근
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.320-326
    • /
    • 1994
  • The KITSAT-1 (Auguse, 1992) and the KITSAT-2(September, 1993) were successfully launched and operated by the SatRec(Satellite Research Center). Both carry the CCD cameras to monitor the image of the earth. We used the camera bench type automatic equipment in the KSRI(Korea Standards Research Institute) to measure the MTF(Modulation Transfer Function) value of the lens attached to the CCD camera. We measured the tangential MTF and the sagital MTF by varing the f-number and the field angle. According to the result, the light from a point source is focused within one pixel of the CCD chip when the f-number is smaller than 4.0, and the MTF value becomes smaller as the field angle increases.

  • PDF

BATHYMETRIC MODULATION ON WAVE SPECTRA

  • Liu, Cho-Teng;Doong, Dong-Jiing
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.344-347
    • /
    • 2008
  • Ocean surface waves may be modified by ocean current and their observation may be severely distorted if the observer is on a moving platform with changing speed. Tidal current near a sill varies inversely with the water depth, and results spatially inhomogeneous modulation on the surface waves near the sill. For waves propagating upstream, they will encounter stronger current before reaching the sill, and therefore, they will shorten their wavelength with frequency unchanged, increase its amplitude, and it may break if the wave height is larger than 1/7 of the wavelength. These small scale (${\sim}$ 1 km changes is not suitable for satellite radar observation. Spatial distribution of wave-height spectra S(x, y) can not be acquired from wave gauges that are designed for collecting 2-D wave spectra at fixed locations, nor from satellite radar image which is more suitable for observing long swells. Optical images collected from cameras on-board a ship, over high-ground, or onboard an unmanned auto-piloting vehicle (UAV) may have pixel size that is small enough to resolve decimeter-scale short gravity waves. If diffuse sky light is the only source of lighting and it is uniform in camera-viewing directions, then the image intensity is proportional to the surface reflectance R(x, y) of diffuse light, and R is directly related to the surface slope. The slope spectrum and wave-height spectra S(x, y) may then be derived from R(x, y). The results are compared with the in situ measurement of wave spectra over Keelung Sill from a research vessel. The application of this method is for analysis and interpretation of satellite images on studies of current and wave interaction that often require fine scale information of wave-height spectra S(x, y) that changes dynamically with time and space.

  • PDF

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF