• Title/Summary/Keyword: light direction

Search Result 853, Processing Time 0.03 seconds

Viewing Angle Enhancement of Light Direction Controllable Integral Imaging Three-dimensional Display System by Moving Aperture in 4-f Illumination Optics

  • Shin, Min-Young;Park, Jae-Hyeung;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1341-1344
    • /
    • 2009
  • A novel method to control the viewing direction by moving aperture location in 4-f illumination optics to control light direction is proposed. Based on integral imaging principle, the relayed point light sources by 4-f optics are modulated by a spatial light modulator, displaying three-dimensional images. In the proposed method, we locate the aperture, which acts as a band pass filter, around an optic axis to control the light direction. Resultantly, assuming that we know the viewer position by a tracking system, we can display appropriate three-dimensional images over large viewing angle.

  • PDF

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

PVA Fiber Incorporation Effect According to Light Transmission Direction of LEFC (빛 투과 방향에 따른 LEFC의 PVA섬유 혼입 효과)

  • Seo, Seung-Hoon;Kim, Tae-Wan;Kang, Young-Un;Jeon, Seung-Heon;Oh, Sang-Kun;Kim, Byoung-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.17-18
    • /
    • 2018
  • With the technological advancement of the construction industry, construction materials with future direction appeared. In Korea, LEFC(Light Emotion Friendly Concrete) has been developed and studied, which has improved labor productivity and economic efficiency over semi-transparent concrete by introducing transparent plastic rods into concrete matrix. However, there is a problem in that the bending performance is lowered according to the insertion of the rod and the bending performance is different according to the light transmission direction. In this study, the incorporation of PVA fibers in the direction of light transmission was increased and the change of flexural performance according to the interval of light transmission was examined.

  • PDF

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.

A study on surface roughness depending on cutting direction and cutting fluid type during micro-milling on STAVAX steel (STAVAX 강의 마이크로 밀링 중 가공 방향 및 절삭유체 분사형태에 따른 표면 거칠기 경향에 관한 연구)

  • Dong-Won Lee;Hyeon-Hwa Lee;Jin Soo Kim;Jong-Su Kim
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.22-26
    • /
    • 2023
  • As Light-Emitting Diodes(LEDs) continue to advance in performance, their application in automotive lamps is increasing. Automotive LEDs utilize light guides not only for aesthetics but also to control light quantity and direction. Light guides employ patterns of a few hundred micrometers(㎛) to regulate the light, and the surface roughness(Ra) of these patterns can reach tens of nanometers(nm). Given that these light guides are produced through injection molding, mold processing technology with high surface quality micro-patterns is required. This study serves as a preliminary investigation into the development of high surface quality micro-pattern processing technology. It examines the surface roughness of the workpiece based on the cutting direction of the pattern and the cutting fluid type when cutting micro-patterns on STAVAX steel using cubic Boron Nitride(cBN) tools. The experiments involved machining a step-shaped micro-pattern with a height of 60 ㎛ and a pitch of 400 ㎛ in a 22×22 mm area under identical cutting conditions, with only the cutting direction and cutting fluid type being varied. The machining results of four cases were compared, encompassing two cases of cutting direction(parallel to the pattern, orthogonal to the pattern) and two cases of cutting fluid type (flood, mist). Consequently, the Ra value was found to be the highest(Ra 128.33 nm) when machining with the flood type in parallel to the pattern, while it was the lowest(Ra 95.22 nm) when machining with the mist type orthogonal to the pattern. These findings confirm that there is a difference of up to 25.8 % in the Ra value depending on the cutting direction and cutting fluid type.

Study on Luminance Characteristics in a Design of LED Backlight by the Light-Entering Face Treatment (LED 백라이트 설계에서 입광부처리에 따른 휘도분포의 광학적 해석)

  • Han, Jeong-Min;Kim, Byoung-Yong;Kim, Jong-Yeon;Kim, Jong-Hwan;Kim, Young-Hwan;Lee, Sang-Keuk;Ok, Chul-Ho;Kang, Dong-Hun;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.429-429
    • /
    • 2007
  • In this study, it was investigated about the variation of luminance properties in LED backlight with geometrical shape such as prism or lens shape on the light-entering face. Generally, LED light source has the loss in backlight system because it has horizontal direction light. PMMA(Poly-Methyl-Meta-Acrylate) is used LGP(Light-Guide-Plate) in conventional backlight system. PMMA has low refraction angle. so that. horizontal direction light was not used in backlight system. The addition of geometrical shape in light-entering face in LGP improves the luminance characteristics because it prevents horizontal direction light generation in light-entering-face. Prism or lens shape in same pitch disposition was almost same without these treatment such as the value of 1% rising. Besides. It is particular that the gap of these shape such as the value of 0.407~0.22mm prevents horizontal direction light, so then it contributes luminance rising at 5.6%.

  • PDF

Investigation of Seismic Responses of Single- and Bi-Directional Traffic Light Poles (단방향 및 양방향 교통신호등주의 지진응답 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Oh, Jongwon;Roh, Hwasung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.219-226
    • /
    • 2022
  • The seismic responses of traffic light poles are investigated using a finite element analysis. Among the traffic light poles, single- and bi-directional traffic light poles are considered since such poles are frequently installed on vehicle roads. For a more detailed investigation, three different lengths of the mast arm are considered for each directional pole. For a time-history analysis, six actual and two artificial earthquakes are considered and applied to each direction of the poles (x and y) to investigate which direction input provides more significant responses due to the unsymmetrical structural shape. Herein, the x and y directions are respectively parallel and perpendicular based on the single mast pole case. From the analysis results, the average maximum displacement response is developed with the x-direction input case for both types of light poles. Also, the bi-directional traffic light poles show a 13% larger response than the single-directional traffic light poles. Even though the y-direction input case produces a smaller response, the response difference between the single- and bi-directional light poles considerably increases by about 60%. The average maximum acceleration responses are almost similar for both types of light poles.

A Study on Ceiling Light and Guided Line based Moving Detection Estimation Algorithm using Multi-Camera in Factory

  • Kim, Ki Rhyoung;Lee, Kang Hun;Cho, Su Hyung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.70-74
    • /
    • 2018
  • In order to ensure the flow of goods available and more flexible, reduce labor costs, many factories and industrial zones around the world are gradually moving to use automated solutions. One of them is to use Automated guided vehicles (AGV). Currently, there are a line tracing method as an AGV operating method, and a method of estimating the current position of the AGV and matching with a factory map and knowing the moving direction of the AGV. In this paper, we propose ceiling Light and guided line based moving direction estimation algorithm using multi-camera on the AGV in smart factory that can operate stable AGV by compensating the disadvantages of existing AGV operation method. The proposed algorithm is able to estimate its position and direction using a general - purpose camera instead of a sensor. Based on this, it can correct its movement error and estimate its own movement path.

Electrical Conductivity and Optical Properties of Elongated Conducting Polymer (연신도전성고분자의 전기전도와 광학적 특성)

  • 박대희;강성화;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.59-62
    • /
    • 1994
  • Tact Electrical conductivity. optical absorption spectra of poly(p-phenylene vinylene) and their dependence on stretching are discussed in detail. The conductivity in the parallel direction to the stretching is higher over one order in magnitude than that in the perpendicular direction to the stretching is higher over one order in magnitude than that in the perpendicular direction to the stretching. The photocurrent spectrum for the ligh polarized parallel to the chain direction is much enhanced in lower photon energy compared with that for the light polarized perpendicular to that direction. The result may be originated in the difference of energies which is needed to photogenerate carriers wi th the light polarized parallel and perpendicular to the chain stretched direction.

  • PDF

Polymer Light-Emitting Diodes Based on Poly(3-hexyl thiophene)

  • Chang, Seoul;Kim, Nam-Hee
    • Fibers and Polymers
    • /
    • v.1 no.1
    • /
    • pp.25-31
    • /
    • 2000
  • Poly(3-hexyl thiophene)(P3HT) and poly(3-dodecyl thiophene)(P3DT) were polymerized by oxidative coupling with ferric chloride. The P3HT light-emitting device emitted red light and it could be observable in the ordinary indoor light. The device had the turn-on electric field of about 3$\times$$10^7$ V/m. The maximum electroluminescene (EL) intensity was obtained when the thickness of polymer layer was about 130 nm in IT0/P3HT/Al device. The maximum external quantum yield was 0.002%. The maximum luminance was 21 cd/$m^2$. The EL intensity decreases with increasing the crystallinity of the polymer layer. By using the oriented poly(3-alkyl thiophene)(PAT) layer as an electroluminescent layer in the ITO/polymer/Al light-emitting devices, the polarized EL light emission was observed. The EL intensity ratio of parallel to perpendicular direction to the stretch direction for P3HT was about 1.40.

  • PDF