• 제목/요약/키워드: light curing

검색결과 464건 처리시간 0.026초

삼차원 마이크로광조형 기술 응용을 위한 광경화 수지 EA1260T의 경화특성 조절에 대한 연구 (Modification of the curing characteristics of the photocurable resin FA1260T for 3D microfabrication using microstereolithography)

  • 김성훈;정대준;주재영;정성호
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.174-179
    • /
    • 2006
  • The curing characteristics of a photocurable resin are critical factors that often decide the ultimate resolution and structural sharpness of a final product fabricated by microstereolithography$(\mu-STL)$. In this study, we investigated the curing characteristics of the FA1260T photopolymer under a visible laser light of 42nm wavelength. Modification of the curing property of the FA1260T is attempted to reduce the cure depth $(D_c)$ by adding a radical quencher to the resin. Also, an organic solvent was used to reduce the resin viscosity for an improvement of the flatness of the liquid surface during layer-by-layer curing. As a result, the minimum $D_c$ has been reduced over a factor of 3 with no abrupt increase. Samples of three dimensional microstructures fabricated using the modified FA1260T are presented.

약한 광중합과 열경화를 이용한 곡면 미세 표면주름 제작 (Fabrication of Microscale Wrinkles on a Curved Surface Using Weak-Polymerization and Thermal Curing Process)

  • 양정호;조지준;박상후
    • 한국정밀공학회지
    • /
    • 제33권10호
    • /
    • pp.875-880
    • /
    • 2016
  • In this study, we proposed an effective and simple way to directly generate wrinkle patterns on a curved surface. A curved surface was prepared using a 3D printer and an UV (Ultraviolet)-lighting system was utilized to weakly polymerize the UV-curable thin resin layer coated on the surface, resulting in a gradient of material properties in the layer thickness. Subsequently, a thermal curing process was conducted to generate microscale wrinkles by compressive forces that were generated during complete curing. Wrinkle shapes from 5, 15, 25 sec of UV-light exposure were compared. With increasing UV-exposure, the line-width of wrinkles became thicker due to much higher strength of skin zone. The results indicated that the proposed fabrication process could be utilized for surface modification in diverse research fields.

브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교 (The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods)

  • 신재호;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.333-342
    • /
    • 2004
  • 기존의 가시광선 중합기와 비교해서 plasma are light와 LED) 방식의 중합기를 이용해 브라켓을 치아표면에 접착한 후 탈락시키는 실험을 시행해 각각의 중합방식별로 전단결합강도와 접착파절양상을 비교함으로써 임상에서의 유용성을 평가하고자 하였다. 교정치료를 위해 발거한 상, 하악 소구치 60개를 윈통형의 레진블록에 매몰하여 시편을 제작하였다. 광중합형 접착레진인 Transbond XT를 이용하여 광중합 방식별로 조건(가시광선 중합기는 40초, LED방식의 중합기는 20춘, 그리고 plasma arc light 방식의 중합기는 3초)에 따라 브라켓을 접착한 후 만능물성실험기로 전단결합강도를 측정하고 브라켓 기저면을 광학현미경으로 관찰해 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 가시광선 중합방식과 LED 중합방식으로 중합시킨 군간에 전단결합강도의 유의성 있는 차이는 없지만 plasma arc Light방식으로 중합시킨 군은 앞의 두 군에 비해 유의성이 있게 작은 간을 나타내었다(p>0.05). 2. 가시광선 중합방식으로 중합한 군과 LED방식을 이용한 군에서는 파절양상이 거의 유사하게 나타났다. 두 군 모두 잔류접착제가 치아면에만 있는 경우가 제일 적은 비율을 도였으며 브라켓 기저면에 50% 이상의 집착제가 남아 있는 양상이 더 큰 비율을 보였다. 3. Plasma arc light 로 중합시킨 경우에는 접착제가 브라켓 기저면에 50% 이하로 남아있는 양상이 큰 비율로 나타났으며 잔류 접착제 전체가 치아면에 남아 있는 경우는 15%였다. 이상의 실험결과 plasma arc light를 이용한 중합 방식이 가시광선이나 LED 방식을 이용한 중합 방식에 비해 유의성 있게(p>0.05) 낮은 전단결합강도를 보였으나 세 방식 모두 인상적으로 사용하기에 충분한 전단결합강도를 보여 유용하게 사용할 수 있음을 알 수 있었다.

DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석 (Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

LED 광중합기의 조사 mode가 복합레진의 미세경도 및 수축응력에 미치는 영향 (INFLUENCE OF IRRADIATION MODES ON THE MICROHARDNESS AND THE POLYMERIZATION CONTRACTION OF COMPOSITE RESIN POLYMERIZED WITH LED CURING UNIT)

  • 박인호;오유향;이난영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제32권2호
    • /
    • pp.312-320
    • /
    • 2005
  • 이 연구의 목적은 LED 광중합기(Elipar Freelight $2^{(R)}$, 3M-ESPE, USA)의 조사 mode에 따른 복합레진($Supreme^{(R)}$, Filtek $Flow^{(R)}$, 3M-ESPE, USA)의 수축응력과 미세경도를 평가하는 것이다. 수축응력을 측정하기 위해 스트레인 게이지가 사용되었다. 표본은 조사 mode와 충전방법에 따라 6개의 군으로 나누어졌다. A군 : Filtek $Flow^{(R)}$ 이장, $Supreme^{(R)}$ 충전, 10초 광중합, B군 : Filtek $Flow^{(R)}$ 이장 $Supreme^{(R)}$ 충전, 15초 광중합, C군 : Filtek $Flow^{(R)}$ 이장, $Supreme^{(R)}$ 충전, 15초 soft start 광중합, D군 : $Supreme^{(R)}$ 충전, 10초 광중합, E군 : $Supreme^{(R)}$ 충전, 15초 광중합, F군 : $Supreme^{(R)}$ 충전, 15초 soft start광중합. 스트레인 게이지를 아크릴릭 링에 부착하고 strainmeter에 연결한 후 광중합하고 10분 동안 1초 간격으로 측정하고 기록하였다. 24시간 후에 각각 표본의 미세경도를 측정하였다. 결과는 ANOVA와 Tukey test를 이용해 통계학적으로 분석하였다. 결과는 다음과 같았다. 1. Soft start curing 했을 때 수축응력이 낮았다(p<0.05). Flowable resin을 이장한 군에서는 효과가 없었다. 2. 10초간 조사한 군은 15초간 조사한 군에 비해 수축응력이 적었다(p<0.05). 3. 미세경도 측정결과 상면과 하면에서 각 군 간에 차이는 없었다(p>0.05). 하지만, 하면의 미세경도가 상면에 비해 80%에 이르지 못했다.

  • PDF

Effect of light-curing, pressure, oxygen inhibition, and heat on shear bond strength between bis-acryl provisional restoration and bis-acryl repair materials

  • Shim, Ji-Suk;Lee, Jeong-Yol;Choi, Yeon-Jo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.47-50
    • /
    • 2015
  • PURPOSE. This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat. MATERIALS AND METHODS. Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.2 Mpa; oxygen inhibition- applied an oxygen inhibitor around the repaired material,; heat treatment - performed heat treatment in a dry oven at $60^{\circ}C$, $100^{\circ}C$, or $140^{\circ}C$. The shear bond strength was measured with a universal testing machine, and the shear bond strength (MPa) was calculated from the peak load of failure. A comparison of the bond strength between the repaired specimens was conducted using one-way ANOVA and Tukey multiple comparison tests (${\alpha}$=.05). RESULTS. There were no statistically significant differences in the shear bond strength between the control group and the light curing, pressure, and oxygen inhibition groups. However, the heat treatment groups showed statistically higher bond strengths than the groups treated without heat, and the groups treated at a higher temperature resulted in higher bond strengths. Statistically significant differences were seen between groups after different degrees of heat treatment, except in groups heated at $100^{\circ}C$ and $140^{\circ}C$. CONCLUSION. Strong bonding can be achieved between a bis-acryl base and bis-acryl repair material after heat treatment.

Impact of UV curing process on mechanical properties and dimensional accuracies of digital light processing 3D printed objects

  • Lee, Younghun;Lee, Sungho;Zhao, Xing Guan;Lee, Dongoh;Kim, Taemin;Jung, Hoeryong;Kim, Namsu
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.161-166
    • /
    • 2018
  • In the last decade, there has been an exponential increase of scientific interest in smart additive manufacturing (AM) technology. Among the different AM techniques, one of the most commonly applied processes is digital light processing (DLP). DLP uses a digital projector screen to flash an ultraviolet light which cures photopolymer resins. The resin is cured to form a solid to produce parts with precise high dimensional accuracy. During the curing process, there are several process parameters that need to be optimized. Among these, the exposure time affects the quality of the 3D printed specimen such as mechanical strength and dimensional accuracy. This study examines optimal exposure times and their impact on printed part. It was found that there is optimal exposure time for printed part to have appropriate mechanical strength and accurate dimensions. The gel fraction and TGA test results confirmed that the improvement of mechanical properties with the increasing UV exposure time was due to the increase of crosslinked network formation with UV exposure time in acrylic resins. In addition, gel fraction and thermogravimetric analysis were employed to microscopically investigate how this process parameter impacts mechanical performance.

Glass ionomer cement초기 경화시 수분접촉의 영향에 관한 연구 (THE EFFECT OF EARLY WATER CONTACT ON GLASS-IONOMER CEMENTS)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.507-513
    • /
    • 1993
  • 본 연구의 목적은 3종의 일반적 glass ionomer cement과 1종의 광중합형 glass ionomer cement을 자료로 하여 연화후 3, 5, 7, 10분 경과시켜 methylene blue용액에 침적하여 그침투를 측정하여 물의 영향을 관찰하고 이상의 시간과 관련하여 수분과 접촉시 그 용해도를 zinc phosphate와 polycarboxylate cement와 비교관찰하였다. blue stained zone은 모든 glass ionomer cement에서 나타났고 inner opaque zone은 두종의 regular glass ionomer cement에서만 나타났다. 연화시작부터 물에 침적시키는 사이시간이 연장되매 따라 모든 cement에서 두 zone의 후경이 감소하였고 regular glass ionomer cement의 면으로 부터 물질의 손실량은 현저히 감소하였으며 물질의 손실량에 대해서는 light curing glass ionomer cement는 시간에 거의 영향을 받지 않았으며 zinc phosphate cement파 polycarboxylate cement도 이와 유사성을 보였다.

  • PDF

광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구 (Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin)

  • 최용훈;배지현;손호현;이인복;백승호;엄정문;김오영;김창근;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.177-184
    • /
    • 2004
  • 본 연구는 광중합형 상아질 접착제에서 광조사 시간의 증가가 접착제 표면의 미중합층에 대한 영향과 그에 따른 전단접착강도에 대해 연구하고자 120개의 치아를 아크릴 몰드에 식립한 후 상아질이 노출되도록 연마하였다. 3종류의 접착제 〔All Bond2 (AB2), One-Step (OS) and Adper Prompt (AP)〕를 40개 치아에 제조사의 지시대로 도포한 후 각각 다른 광조사 시간 (10, 20, 30 and 60sec)동안 광조사 하고 복합레진을 접착한 24시간 후 전단접 착강도를 측정하였다. 미중합층의 두께와 중합률은 슬라이드 글라스와 FT-NIR을 이용하여 FT-NIR spectrum에서의 peak height를 비교 측정하여 다음과 같은 결론을 얻었다. 1. 전단접착강도에서 AB2는 20초 이후 감소하고, AP는 30초까지 증가하였으며,OS는 차이를 보이지 않았다. 2. 미중합층 두께는 3가지 접착제 모두 유의성 있는 차이를 보이지 않았다. 3. 중합률에서 OS는 10초와 나머지군 사이에 유의성 있는 차이를, AP는 60초에서 유의성 있게 증가되고, AB2의 경우 차이를 나타내지 않았다.

방향족 도입에 의한 자외선 경화형 프리즘시트의 휘도 개전 (Improvement of Brightness in UV Curing Type Prism Sheet by Using Aromatic Groups)

  • 김동열;김형일
    • 폴리머
    • /
    • 제33권5호
    • /
    • pp.413-419
    • /
    • 2009
  • 프리즘 시트의 프리즘 층 물질의 굴절률을 증가시킬수록 휘도가 향상되어 LCD 백라이트 유닛의 효율이 향상되었다. 프리즘 층의 굴절률을 증가시키기 위해서 방향족을 포함하고 있는 고굴절 물질과 다관능성 반응물을 혼합하여 자외선 경화형 수지를 제조하였다. 9,9-Bis [4-(2-acryloyloxyethoxy)phenyl] fluorene을 반응시켜 프리즘층의 도막 굴절률을 1.58까지 증가시켰고 백라이트의 휘도를 향상시킬 수 있었다. 백라이트 유닛에 사용되는 광원에 장기간 노출될 경우 프리즘 시트에 황변현상이 발생하게 되어 휘도가 감소되므로 자외선 안정제로 hindered amine light stabilizer를 사용하여 프리즘 시트의 내황변성을 크게 향상시켰다.