• Title/Summary/Keyword: light condition

Search Result 2,486, Processing Time 0.032 seconds

Effect of Night Illumination on Growth and Grain Yield of Wheat and Barley (야간조명에 대한 대ㆍ소맥의 생육 및 수량반응)

  • 김영용;김충국;김시주;강병화
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • This experiment was conducted to investigate the effect of night illumination on the growth and yield of wheat and barley. Three varieties of barley and four cultivars of wheat were tested under the different night illuminance which was controlled in the range of 1.2∼20 Lux during whole growth season at night. As night illumination was stronger, the culm length of all varieties tended to be shorter. The shortening was greater in barley than wheat. Node number, awn length and culm diameter tended to decrease as the light intensity was stronger. Internode length above the 4th and 5th node was remarkably decreased by the stronger illuminance. The degree of decrease in spike length affected by the night illuminance was much larger in the late-maturing variety among wheat cultivars. As night illumination was stronger, days to heading was shortened in general. The range of decrease was 2 to 10 days under 10∼20 Lux condition similarly in both barley and wheat. Effect of night illumination on heading date and days from initial heading to full heading was not considerably different between the crops and among varieties except Kangbori. Night illumination decreased the grain yield by 12.5% in barley, and 11.0% in wheat at 2.1∼5.0 Lux condition, and 34.6% in barley, and 29.3 % in wheat at 10∼20 Lux condition compared to control. Yield reduction was significantly different among varieties, being greatest in Kangbori among barley varieties, and in Chokwang (late-maturring variety) and Changkwang (late-maturring variety) among wheat varieties. It was interpreted that the decrease of grain yield was resulted from the decrease in the number of spikes and the number of grains per spike under the stronger night illumination. The decrease of grain yield was more directly attributed to the decrease in the number of grains per spike.

Barley Sowing by Partial Tillage Direct Grain Seeder in Wet Paddy Field (논 과습포장에서 부분경운 건답직파기를 이용한 보리 파종)

  • Koo, Bon-Cheol;Kim, Jae-Cheol;Yang, Yon-Ha;Kang, Moon-Seok;Cho, Young-Son;Park, Seok-Ho;Park, Kwang-Geun;Lee, Choon-Ki;Shin, Jin-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.52 no.3
    • /
    • pp.259-263
    • /
    • 2007
  • Sowing time of barley after cultivation of rice has frequently been delayed because of rainfall or some other reasons by rice cultivation. Partial tillage direct grain seeder with eight row, which had been developed for rice sowing and showed many advantages in wet field, were tested for barley sowing. After flooding during $2{\sim}3days$, plots were designed to make wet condition. Three sowing methods were tested; high ridged broadcasting, plat drill seeding and partial tillage direct grain seeding. It were impossible to sow properly even in 27% of soil water content by high ridged broadcasting, plat drill seeding but could be possible to sow normally by partial tillage direct grain seeder in 42% of soil water content as good as in 27% of soil water content. Initial growth condition after sowing in plots of partial tillage direct grain seeder were normal even in plots sown in more than 50% of soil water content. No. of spike, which was $508/m^2$, in plot of partial tillage direct grain seeder sowed at 30% soil water content was better than plat drill seeding, $404/m^2$. Yield and yield components of plot of partial tillage direct grain seeder, were higher than plot sowed by plat drill seeder in same soil water content. Partial tillage direct grain seeding can be a good sowing way for barley especially in wet condition. However, parts of seeder have to be improved for barley sowing; 1) ridged width of partial tillage direct grain seeder should be $10{\sim}20cm$ wider than 10 cm, which is necessary for drainage during barley growing season in wet paddy field. 2) sowing width of partial tillage direct grain seeder was not same with one of drill seeder which was the best width for light interception and should be shorter than 30cm.

Effect of Torrefaction Condition on The Chemical Composition and Fuel Characteristics of Larch wood (낙엽송재의 화학적 조성 및 연료적 특성에 대한 반탄화 조건의 영향)

  • Kim, Sang Tae;Lee, Jae-Jung;Park, Dae-Hak;Yang, In;Han, Gyu-Seong;Ahn, Byoung Jun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.122-134
    • /
    • 2015
  • This study was conducted to investigate the potential of torrefied larch wood as a raw material of pellets. First of all, larch chip was torrefied at the temperatures of 230, 250 and $270^{\circ}C$ for 30, 50 and 70 min. Secondly, moisture content, moisture absorption, higher heating value and ash content of the torrefied chip were measured to examine the effects of torrefaction conditions on the fuel characteristics of larch. Thirdly, surfaces of the torrefied chip were observed by light microscope (LM), field emission scanning microscope (FE-SEM) and SEM-energy dispersive spectroscopy (EDXS). With the increases of torrefied temperature and time, contents of lignin increased and those of hemicellulose reduced. Moisture content of torrefied larch chip was greatly lower than that of non-torrefied chip. Moisture absorption of the torrefied chip decreased as torrefaction temperature increased. As torrefaction temperature increased, higher heating value and ash content of larch chip increased. However, durability of torrefied-larch pellets was remarkably lower comparing to non-torrefied-larch pellets. When surface of larch chip was observed by LM and FE-SEM, surface color and cell wall of the chip was getting darker and more collapsed with the increases of torrefaction conditions. Through the analysis of SEM-EDXS, distribution and quantity of lignin existing on the surface of larch chip increased with the increases of torrefied conditions. In conclusion, $270^{\circ}C$/50 min might be an optimal condition for the torrefaction of larch with the aspect of fuel characteristics, but torrefaction condition of $230^{\circ}C$/30 min should be considered according to the durability of torrefied-larch pellets.

Studies on Germination Characteristics and Differential Responses to Herbicides in Setaria Spp. (강아지풀 종류별 종자발아특성과 제초반응 차이)

  • Kim, J.S.;Kim, T.J.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.16 no.3
    • /
    • pp.187-193
    • /
    • 1996
  • To supply seeds with a good quality as plant materials for herbicide screening and to know whether the germination characteristics could be associated with a differential response to herbicides, germination characteristics and differential responses to herbicides were investigated with 3 species of a genus Setaria ; Yellow foxtail(Setaria glauca P. Beauv, SETGL), Giant foxtail(Setaria faberi Hetrm, SETFA), and Green foxtail(Setaria viridis P. Beauv, SETVI). Degree of dormancy was high in the order of SETGL, SETVI and SETFA. The dormancy of SETGL seed was relatively well removed by room temperature and drying storage, but SETFA and SETVI by low temperature and wetting storage(stratification). For breaking dormancy of SETGL, SETVI and SETFA, it was necessary for being kept under the above storage conditions for at least 2, 4 and 4-5 months, respectively. When the dormancy-breaked seeds were transfered to low temperature($4^{\circ}C$) and drying condition, SETGL showed germination rate of 96% even after 2 month storage. However, SETVI and SETFA showed a decreased germination of 54% and 69%, respectively, with a decreased velocity of germination, indicating that secondary dormancy might be induced. On the other hand, a significant change in germination rate was not observed as the seeds were transfered to room temperature($25^{\circ}C$) and drying condition. The germinability of SETGL seed began to decline from 6th year after storage in room temperature and drying condition. All of 3 species showed relatively high germination rate at alternating temperature of $30^{\circ}C$/$20^{\circ}C$(14hr/10hr) and their germination were not increased by light. All of 3 species exhibited similar responses to cycloxydim, sethoxydim and primisulfuron in greenhouse experiment. In contrast, SETVI and SETFA were relatively susceptible to fenoxapropethyl, SETFA to fluazifop-butyl, SETGL and SETFA to clorimuron-ethyl, and SETGL to EK-2612. The difference in herbicidal response among 3 species was the highest in the treatment of EK-2612. These results suggest that there is no a consistent tendency in responses of 3 species to herbicides which have the same target site. And the relationship between germination characteristics and differential responses to herbicides was not found.

  • PDF

Charaterization of Biomass Production and Wastewater Treatability by High-Lipid Algal Species under Municial Wastewater Condition (실제 하수조건에서 고지질 함량 조류자원의 생체생성과 하수처리 특성 분석)

  • Lee, Jang-Ho;Park, Joon-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • Wastewater treatment using algal communities and biodiesel production from wastewater-cultivated algal biomass is a promising green growth technology. In literature, there are many studies providing information on algal species producing high content of lipid. However, very little is known about adaptability and wastewater treatability of such high-lipid algal species. In this study, we attempted to characterize algal biomass production and wastewater treatability of high-lipid algal species under municipal wastewater condition. For this, four known high-lipid algal strains including Chlorella vulgaris AG 10032, Ankistrodesmus gracilis SAG 278-2, Scenedesmus quadricauda, and Botryococcus braunii UTEX 572 were individually inoculated into municipal wastewater where its indigenuous algal populations were removed prior to the inoculation, and the algae-inoculated wastewater was incubated in the presence of light source (80${\mu}E$) for 9 days in laboratory batch reactors. During the incubations, algal biomass production (dry weight) and the removals of dissolved organics (COD), nitrogen and phosphorous were measured in laboratory batch reactors. According to algal growth results, C. vulgaris, A. gracilis and S. quadricauda exhibited faster growth than indigenuous wastewater algal populations while B. braunii did not. The wastewater-growing strains exhibited efficient removals of total-N, ${NH_4}^+$-N, Total-P and ${PO_4}^{3-}$-P which satisfy the Korea water quality standards for effluent from municipal wastewater treatment plants. A. gracilis and S. quadricauda exhibited efficient and stable treatability of COD but C. vulgaris showed unstable treatability. Taken together with the results, A. gracilis and S. quadricauda were found to be suitable species for biomass production and wastewater treatment under municipal wastewater condition.

Performance of Waste-air Treating System Composed of Two Alternatively-operating UV/photocatalytic Reactors and Evaluation of Its Characteristics (교대로 운전되는 두 개의 UV/광촉매반응기로 구성된 폐가스 처리시스템의 성능 및 특성 평가)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.574-583
    • /
    • 2021
  • Waste air containing ethanol (100 ppmv) and hydrogen sulfide (10 ppmv) was continuously treated by waste air-treating system composed of two annular photocatalytic reactors (effective volume: 1.5 L) packed with porous SiO2 media carrying TiO2-anatase photocatalyst, one of which was alternately operated for 32 d/run while the other was regenerated by 100 ℃ hot air with 15 W UV(-A)-light on. As its elimination-behavior of ethanol, the removal efficiencies of ethanol at 1st, 2nd and 3rd operation of the photocatalytic reactor system(A), turned out to be ca. 60, 55 and 54%, respectively, at their steady state condition. Unlike the elimination-behavior of ethanol, its hydrogen sulfide-elimination behavior showed repeated decrease of hydrogen sulfide removal efficiency by its resultant arrival at a lower level of steady state condition. Nevertheless, the removal efficiencies of hydrogen sulfide at 1st, 2nd and 3rd operation of the photocatalytic reactor system, turned out to be ca. 80, 75 and 73%, respectively, at their final steady state condition, higher by ca. 20, 20 and 19% than those of ethanol, respectively. Therefore, assuming that adsorption on porous SiO2-photocatalyst carrier was regarded to belong to a reversible deactivation and that decreased % of removal efficiency due to the reversible deactivation of photocatalyst including the adsorption was independent of the number of its use upon regeneration, the increments of the decreased % of removal efficiency of ethanol and hydrogen sulfide, due to an irreversible deactivation of photocatalyst, for the 3rd use of regenerated photocatalyst, compared with the 2nd use of regenerated photocatalyst, were ca. 1 and 2%, respectively, which was insignificant or the less than those of ca. 5 and 5%, respectively, for the 2nd use of regenerated photocatalyst compared with the 1st use of virgin photocatalyst. This trend of the photocatalytic reactor system was observed to be similar to that of the other alternately-operating photocatalytic reactor system.

Effect of storage condition of resin cement on shear bond strength of the orthodontic bracket (레진시멘트의 보관 조건이 치열교정용 브라켓의 전단접착강도에 미치는 영향)

  • Seul-Gi, Yi;Jin-Woo, Kim;Se-Hee, Park;Yoon, Lee;Eung-Hyun, Kim;Kyung-Mo, Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.189-195
    • /
    • 2022
  • Purpose: For orthodontic bracket bonding, light curing resin cement is widely used because the process is convenient, and it can be polymerized at the desired time. This study compared the difference of bonding strength of orthodontic resin cement according to storage condition. Materials and Methods: After acid etching the bovine enamel surface with 37% phosphoric acid, 15 orthodontic brackets for mandible incisors were bonded with Ortho Connect and Orthomite LC according to following three conditions; 1) Immediate after 4℃ refrigeration for 3 months (IR), 2) One day room temperature after 4℃ refrigeration for 3 months (OR), 3) Room temperature for 3 months (RT). The shear bond strength was measured with a universal material tester and failure pattern of the specimen was observed. Two-way ANOVA and One-way ANOVA were used at the 95% significance level. Results: Ortho Connect that was applied immediately after refrigeration showed the maximum shear bond strength. Orthomite that was applied immediately after refrigeration showed the lowest shear bond strength, and the group stored at room temperature for three months showed the highest shear bond strength, and the difference between the two groups was significant. Conclusion: Ortho Connect can be used without worrying about bond strength even if it is used immediately after refrigeration, but Orthomite should be kept at room temperature sufficiently after refrigeration.

국내 시판우유의 보관방법별 품질변화에 관한 연구

  • Jeong, Seok-Chan;Kim, Gye-Hui;Jeong, Myeong-Eun;Kim, Seong-Il;Byeon, Seong-Geun;Lee, Deuk-Sin;Park, Seong-Won;Jo, Nam-In;Kim, Ok-Gyeong
    • 한국유가공학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.23-40
    • /
    • 2002
  • This study was conducted to investigate the quality changes of the UHT(ultra-high temperature), LTLT(law temperature long time) and HTST(high temperature short time) treated milk samples by storage conditions for 6 months from August 2000 to February 2001. The UHT treated milk samples collected from 3 plants(A, B and C) were stored at l0$^{\circ}$C and room temperature(dark and light exposure) for 6 months, and the LTLT and HTST treated milk samples(D and E) were also stored for 30 days. The UHT pasteurized milk of A, B and C plant was treated at 130$^{\circ}$C for 2-3s, 133$^{\circ}$C for 2-3s and 135$^{\circ}$C for 4s, respectively. The UHT sterilized milk of A and B plant was treated at 140$^{\circ}$C for 2-3s and 145$^{\circ}$C for 3-4s, respectively. The LTLT milk of D plant was treated at 63$^{\circ}$C for 30 mins, and the HTST milk of E plant was treated at 72$^{\circ}$C for 15s. All of the raw milk samples collected from storage tank in 5 milk plants were showed less than 4.0 X 10$^5$cfu/ml in standard plate count, and normal level in acidity, specific gravity, and component of milk. Preservatives, antibiotics, sulfonamides and available chloride were not detected in both raw and heat treated milk samples obtained from 5 plants. One(10%) of 10 UHT pasteurized milk samples obtained from B plant and 2 (20%) of 10 from C were not detected in bacterial count after storage at 37$^{\circ}$C for 14 days, but all of the 10 milk samples from A were detected. No coliforms were detected in all samples tested. No bacteria were also detected in carton, polyethylene and tetra packs collected from the milk plants. A total of 300 UHT pasteurized milk samples collected from 3 plants were stored at room(3$^{\circ}$C ${\sim}$ 30$^{\circ}$C) for 3 and 6 months, 11.3%(34/300) were kept normal in sensory test, and 10.7%(32/300)were negative in bacterial count. The UHT pasteurized milk from A deteriorated faster than the UHT pasteurized milk from B and C. The bacterial counts in the UHT pasteurized milk samples stored at 10$^{\circ}$C were kept less than standard limit(2 ${\times}$ 10$^4$ cfu/ml) of bacteria for 5 days, and bacterial counts in some milk samples were a slightly increased more than the standard limit as time elapsed for 6 months. When the milk samples were stored at room(3$^{\circ}$C ${\sim}$ 30$^{\circ}$C), the bacterial counts in most of the milk samples from A plant were more than the standard limit after 3 days of storage, but in the 20%${\sim}$30%(4${\sim}$6/20) of the milk samples from B and C were less than the standard limit after 6 months of storage. The bacterial counts in the LTLT and HTST pasteurized milk samples were about 4.0 ${\times}$ 10$^3$ and 1.5 ${\times}$ 101CFU/ml at the production day, respectively. The bacterial counts in the samples were rapidly increased to more than 10$^7$ CFU/ml at room temperature(12$^{\circ}$C ${\sim}$ 30$^{\circ}$C) for 3 days, but were kept less than 2 ${\times}$ 10$^3$ CFU/ml at refrigerator(l0$^{\circ}$C) for 7 days of storage. The sensory quality and acidity of pasteurized milk were gradually changed in proportion to bacterial counts during storage at room temperature and 10$^{\circ}$C for 30 days or 6 months. The standard limit of bacteria in whole market milk was more sensitive than those of sensory and chemical test as standards to determine the unaccepted milk. No significant correlation was found in keeping quality of the milk samples between dark and light exposure at room for 30 days or 6 months. The compositions of fat, solids not fat, protein and lactose in milk samples were not significantly changed according to the storage conditions and time for 30 days or 6 months. The UHT sterilized milk samples(A plant ; 20 samples, B plant ; 110 samples) collected from 2 plants were not changed sensory, chemical and microbiological quality by storage conditions for 6 months, but only one sample from B was detected the bacteria after 60 days of storage. The shelflife of UHT pasteurized milk in this study was a little longer than that reported by previous surveys. Although the shelflife of UHT pasteurized milk made a significant difference among three milk plants, the results indicated that some UHT pasteurized milk in polyethylene coated carton pack could be stored at room temperature for 6 months. The LTLT and HTST pasteurized milk should be sanitarily handled, kept and transported under refrigerated condition(below 7$^{\circ}$C) in order to supply wholesome milk to consumers.

  • PDF

The effects of polishing technique and brushing on the surface roughness of acrylic resin (연마 방법과 칫솔질이 아크릴릭 레진의 표면 거칠기에 미치는 영향)

  • Lee, Ju-Ri;Jeong, Cheol-Ho;Choi, Jung-Han;Hwang, Jae-Woong;Lee, Dong-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.287-293
    • /
    • 2010
  • Purpose: This study evaluated the effect of polishing techniques on surface roughness of polymethyl methacrylate (PMMA), as well as the influence of light-cured surface glaze and subsequent brushing on surface roughness. Materials and methods: A total of 60 PMMA specimens ($10{\times}10{\times}5\;mm$) were made and then divided into 6 groups of 10 each according to the polymerization methods (under pressure or atmosphere) and the surface polishing methods (mechanical or chemical polishing) including 2 control groups. The mechanical polishing was performed with the carbide denture bur, rubber points and then pumice and lathe wheel. The chemical polishing was performed by applying a light-cured surface glaze ($Plaquit^{(R)}$; Dreve-Dentamid GmbH). Accura $2000^{(R)}$, a non-contact, non-destructive, optical 3-dimensional surface analysis system, was used to measure the surface roughness (Ra) and 3-dimensional images were acquired. The surface roughness was again measured after ultrasonic tooth brushing in order to evaluate the influence of brushing on the surface roughness. The statistical analysis was performed with Mann-Whitney test and t-test using a 95% level of confidence. Results: The chemically polished group showed a statistically lower mean surface roughness in comparison to the mechanically polished group (P = .0045) and the specimens polymerized under the atmospheric pressure presented a more significant difference (P = .0138). After brushing, all of the groups, except the mechanically polished group, presented rougher surfaces and showed no statistically significant differences between groups. Conclusion: Although the surface roughness increased after brushing, the chemical polishing technique presented an improved surface condition in comparison to the mechanical polishing technique.

The Characteristics of Membranoproliferative Glomerulonephritis I Detected from School Urine Screening (학교 집단 소변 검사로 발견 된 막증식성 사구체신염 I형의 특성)

  • Choi, Jung-Youn;Park, Mi-Young;Lee, Yong-Jik;Ha, Il-Soo;Cheong, Hae-Il;Choi, Yong;Park, Young-Seo;Han, Hye-Won;Jin, Dong-Kyu;Chung, Woo-Yeong;Kim, Kee-Hyuck;Yoo, Kee-Hwan;Park, Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.10 no.2
    • /
    • pp.152-161
    • /
    • 2006
  • Purpose : In Korea, the school urine screening program is a useful tool for screening urine abnormalities. It is particularly useful in early detection of membranoproliferative glomerulonephritis(MPGN) I, which frequently progresses to chronic renal failure. In this study, we studied the medical history, laboratory findings, and histologic findings of MPGN to gain helpful information on early detection and treatment. Methods : The subjects were 19 children, who were diagnosed with MPGN from kidney biopsies that were performed in ten nationwide university hospitals because of abnormal urine findings from school urine screening programs conducted from July 1999 to April 2004. We divided the patients into 2 groups, a nephrotic range proteinuria group(n=8) and a non-nephrotic proteinuria group(n=11), and retrospectively analyzed the clinical features, laboratory findings, histologic findings, treatment, and clinical course. Results : The mean age at the first abnormal urinalysis was $10.6{\pm}2.2$ years in the nephrotic proteinuria group and $9.6{\pm}3.2$ years in the non-nephrotic proteinuria group. The mean age at the time of kidney biopsy was $11.3{\pm}2.3$ years in the nephrotic range proteinuria group and $10.4{\pm}3.2$ years in the non-nephrotic proteinuria group respectively. There was no significant difference in the mean age and sex between the two groups. In the nephrotic proteinuria group, 6 children had a low plasma C3 level and in the non-nephrotic proteinuria group, 8 children had a low plasma C3 level, but there was no significant difference between the 2 groups. There was no significant difference in the laboratory test results(including WBC count, RBC count, platelet count and other serologic tests) between the 2 groups except for 24 hour urine protein secretion. There was no difference between the 2 groups with regard to the acute and chronic changes in the glomerulus on light microscopic findings, IgG, IgA, Ig M, C1q, C3, C4, fibrogen deposition on immunofluoroscence findings, and mesangial deposits, subendothelial deposits, and subepithelial deposits on electron microscopic findings. The children were treated with corticosteroids, ACE(angiotensin-converting enzyme) inhibitors, dipyridamole and other immunosuppressive agents. During the course of treatment, there were no children whose clinical condition worsened. Among 19 children, 3 children went into remission(2 in the nephrotic proteinuria group, 1 in the non-nephrotic proteinuria group) and 9 children went into a partial remission(4 in the nephrotic proteinuria group, 5 in the non-nephrotic proteinuria group) on urinalysis. There was no significant difference in the treatment results between the two groups. Conclusion : The 73.7% of children who were incidentally diagnosed with MPGN by the school urine screening program had reduced C3. 42.1% of the children had nephrotic range proteinuria. There were no significant differences in clinical features, laboratory test results, light microscopic, immunofluorescence microscopic, and electron microscopic findings between the nephrotic proteinuria group and the non-nephrotic proteinuria group except for the 24 hour urine protein secretion. Therefore, for early detection of MPGN during the school urine screening program, we strongly recommend a kidney biopsy if children have abnormal urine findings such as persistent proteinuria and persistent hematuria, or if the serum C3 is reduced.

  • PDF