• Title/Summary/Keyword: light and lens

Search Result 549, Processing Time 0.028 seconds

Effect of the Sag Height of a PDMS Microlens on the Acceptance Angle of an Artificial Compound Eye (겹눈 모사 구조체에서 마이크로 렌즈의 높이가 빛의 수용각에 미치는 영향 연구)

  • Jihyun, Jung;Mihee, Park;Hyerin, Song;Kyujung, Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2023
  • We have investigated the acceptance angle and imaging performance of a curved artificial compound eye (ACE), depending on the sag height of the microlens array to maximize its sensitivity to light. When the h/r values increased from 0.22 to 0.37, the acceptance angle of the curved ACE was expanded from 28.70° to 49.02°, which is an enhancement by 70.8%. With the designed optical system, it was demonstrated that a microlens located at the 23rd position from the center of the main lens could still focus an incident beam tilted at 56.35°, so that the letter F was clearly observed.

Realization of the multi-phase level CGH according to the multi-channel encoding method using a PAL-SLM (PAL-SLM을 이용한 다채널 부호화 방법에 따른 다위상형 CGH의 광학적 구현)

  • Jung, Jong-Rae;Baek, Woon-Sik;Kim, Jung-Hoi;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.299-308
    • /
    • 2004
  • We proposed more efficient encoding methods that can design a multi-channel multi-level phase only computer-generated hologram(CGH) that can reconstruct many objects simultaneously without a conjugate image. We used a fabrication technique for the pixel oriented CGH for designing the pattern of the proposed multi-channel CGH. We investigated the difference of the optical efficiency(η), mean square error(MSE) and signal-to-noise ratio(SNR) of multi-channel CGHs that were designed by three kinds of encoding methods according to the number of quantization phase levels, and we estimated the performance of the pattern of the proposed multi-channel CGH. Generally, as the number of input objects' reference patterns stored in the CGH is increased, the reconstruction quality of the CGH is degraded. But we observed through computer simulation that the diffraction efficiency of the 1-ch CGH is 70%, and those of the 2-ch, 4-ch, 8-ch CGHs are 62%, 62% and 63%. Therefore we found that the diffraction efficiencies of the multi-channel CGHs using the newly proposed encoding method are similar to that of 1-ch CGH. We implemented the CGH optically using a liquid crystal spatial light phase modulator that consisted of a PAL-SLM efficiently coupled with a XGA type LCD by an optical lens and an LD for illuminating the LCD. We discussed the output images that are reconstructed from the PAL-SLM.

PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR (한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작)

  • Oh, T.H.;Park, K.C.;Kim, Y.H.;Yi, Y.;Kim, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.305-318
    • /
    • 2002
  • We have constructed two flight models of airglow photometer system (AGP) to be onboard Korea Sounding Rocket-III (KSR-III) for detection of MUV dayglow above the Korean peninsular. The AGP system is designed to detect dayglow emissions of OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ and background 3070${\AA}$ toward the horizon at altitudes between 100 km and 300 km. The AGP system consists of a photometer body, a baffle an electronic control unit and a battery unit. The MUV dayglow emissions enter through a narrow band interference filter and focusing lens of the photometer, which contains an ultraviolet sensitive photomultiplier tube. The photometer is equipped with an in-flight calibration light source on a circular plane that will rotate at the rocket's apogee. A bane tube is installed at the entry of the photometer in order to block strong scattering lights from the lower atmosphere. We have carried out laboratory measurements of sensitivity and in-flight calibration light source for the AGP flight models. Although absolute sensitivities of the AGP flight models could not be determined in the country, relative sensitivities among channels are well measured so that observation data during rocket flight in the future can be analyzed with confidence.

Characterization of Electro-wetting Velocity by Measuring Transmission Intensity (광량 측정을 통한 전자습윤 현상의 동작 특성 평가)

  • Park, Seung-Ryong;Song, Seok-Ho;Oh, Cha-Hwan;Kim, Pill-Soo;Oh, Byoung-Do;Chung, Sang-Kug
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • The electro-wetting effect can be implemented as a fast means to move liquid interfaces. A continuous and numerical method would be required in measurement of electro-wetting liquid interfaces. We propose an /in-situ/ measurement method to characterize the dynamic change in curvature of liquid interfaces. In the proposed method, variation of light intensity transmitted through the liquid interfaces is measured, leading to numerical determination of the liquid curvatures. Experimental results obtained from our efficient method are confirmed by the direct images of a streak camera.

Effects of storing defocused Fourier plane holograms in three-dimensional holographic disk memories (디스크형 3차원 홀로그래피 메모리에서 비초점 Fourier 면 홀로그램의 저장 효과)

  • 장주석;신동학
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.1
    • /
    • pp.61-66
    • /
    • 2001
  • Defocused Fourier plane holograms are stored in disk-type holographic memories where thin recording media are used, the areal storage density per hologram and the intensity uniformity of the signal beam at the recording plane are studied. As the pixel pitch of the spatial light modulator that represents binary data increases, the storage density per hologram increases if exact Fourier holograms are stored. When defocused Fourier plane holograms are stored, however, we show that there exists an optimal pixel pitch that maximizes the area storage density per hologram in general, to increase the areal storage density per hologram, f/# of the Fourier transform lens that focuses the data image should be as small as possible. In this case, not only the intensity distribution at the recording plane but also the recording area becomes very sensitive to the degree of defocusing. Therefore, even if the exact Fourier plane holograms are stored, the defocusing effect owing to the medium thickness should be taken into account to achieve the maximal areal storage density per hologram.logram.

  • PDF

Area storage density of ideal 3-D holographic disk memories (이상적인 디스크형 3차원 홀로그래픽 메모리에서의 면적 저장밀도)

  • 장주석;신동학
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.58-64
    • /
    • 2000
  • Assuming that the performance of holographic storage media is ideal, we estimate the area storage density of disk-type holographic memories, when the method of either angle multiplexing, or rotational multiplexing, or both are used. The area storage density is strongly dependent on the f numbers (ratio of focal length to diameter) of both the Fourier transform lens in the signal arm, denoted by $F/#_2$, and the angle range over which the reference beam is incident (or, the equivalent f number corresponding to the angle range denoted by $F/#_1$). The area storage density is largely independent of the pixel pitch of the spatial light modulator when the Fourier plane holograms are recorded, while it is sensitive to the pixel pitch when the image plane holograms are recorded. In general, to obtain high area storage density, the Fourier or at least near Fourier plane holograms rather than the image plane holograms should be recorded. In addition, when the thickness of the recording materials are less than approximately $500\mu\extrm{m}$, rotational multiplexing gives higher area storage densities than angle multiplexing does. To increase the storage density further, however, it is desirable to use both of the two multiplexing methods in combination.nation.

  • PDF

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

KMT-2018-BLG-0029LB: A VERY LOW MASS-RATIO Spitzer MICROLENS PLANET

  • Gould, Andrew;Ryu, Yoon-Hyun;Novati, Sebastiano Calchi;Zang, Weicheng;Albrow, Michael D.;Chung, Sun-Ju;Han, Cheongho;Hwang, Kyu-Ha;Jung, Youn Kil;Shin, In-Gu;Shvartzvald, Yossi;Yee, Jennifer C.;Cha, Sang-Mok;Kim, Dong-Jin;Kim, Hyoun-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Lee, Dong-Joo;Lee, Yongseok;Park, Byeong-Gon;Pogge, Richard W.;Beichman, Charles;Bryden, Geoff;Carey, Sean;Gaudi, B. Scott;Henderson, Calen B.;Zhu, Wei;Fouque, Pascal;Penny, Matthew T.;Petric, Andreea;Burdullis, Todd;Mao, Shude
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.1
    • /
    • pp.9-26
    • /
    • 2020
  • At q = 1.81 ± 0.20 × 10-5, KMT-2018-BLG-0029Lb has the lowest planet-host mass ratio q of any microlensing planet to date by more than a factor of two. Hence, it is the first planet that probes below the apparent "pile-up" at q = 5-10 ×10-5. The event was observed by Spitzer, yielding a microlens-parallax πE measurement. Combined with a measurement of the Einstein radius θE from finite-source effects during the caustic crossings, these measurements imply masses of the host Mhost = 1.14+0.10-0.12 M and planet Mplanet = 7.59+0.75-0.69 M, system distance DL = 3.38+0.22-0.26 kpc and projected separation a = 4.27+0.21-0.23 AU. The blended light, which is substantially brighter than the microlensed source, is plausibly due to the lens and could be observed at high resolution immediately.

UV Absorbent-added Polymerization and its Application as Ophthalmological Material (자외선 흡수제를 첨가한 고분자 중합 및 안 의료용 소재로의 적용)

  • Sung, A-Young;Kim, Tae-Hun;Ye, Ki-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.98-103
    • /
    • 2011
  • This study was done for the preparation of macromolecular material with UV-blocking features by adding the benzophenone group that is commonly used as a UV-absorbent and $TiO_2$ which is known to be a very stable material in chemical and physical aspects. Also, we compared the level of UV absorbency of the polymer produced from polymerization with previous materials and measured basic properties such as water content, refractive index and optical transmittance of produced contact lenses. The results of the measurement showed that the refractive index and water content of the contact lens with added UV-absorbent was 1.430~1.440 and 35.0~45.0% respectively, which was similar to that of previous contact lenses. Also, for optical transmittances of each wave length, contact lenses without the UV-absorbent was 89%, 88% and 89% respectively for UV-A, UV-B and visible light, indicating that the UV transmittance is very high though contrary with cases of contact lenses with added 2-hydroxy-4-methoxy-benzophenone and 2,4-dihydroxy-benzophenone which showed transmittances of 0% and 6% respectively for UV-A and UV-B showing a UV-blocking effect. Meanwhile, contact lenses with added $TiO_2$ showed transmittance of 6% and 51% respectively for UV-A and UV-B also showing a UV-blocking effect. The visible transmittance was 77~89% showing that it satisfies the visible transmittance required for ophthalmological materials.