• Title/Summary/Keyword: ligaments

Search Result 299, Processing Time 0.028 seconds

Cervical Traction (경추견인법)

  • Park Ji-Whan;Park Youn-ki
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.203-209
    • /
    • 1991
  • Cervical traction effects its benefits by immobilizing the neck when it is used in a continuous manner from a reclining position. when used intermittently traction functions by elongating the neck and straightening the cervical Lordosis. This position of slight flexion opens the posterior articulations, widens the intervetebral foramina, disengages the facet surfaces, and elongates the posterior muscular tissues and Ligaments. The duration of traction is arbitary but the amount of traction is that which is tolerated by the patient and benefits the patient's problem. Application of traction in slingh flexion accomplishes the same separation with Less force and thus with Less discomfort experienced by the patient. But the effect of traction on the disks is debated.

  • PDF

Dynamics of a Micro Three-axis Ring Gyroscope (마이크로 3축 링 자이로스코프의 동역학)

  • Kim, Chang-Boo;Choi, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1001-1009
    • /
    • 2002
  • In this paper, we analyse and present mechanical dynamic characteristics of a micro-machined vibrating silicon ring gyroscope which can measure angular velocities about three orthogonal axes. The ring gyroscope has a ring connected to the gyroscope main body by support-ligaments which are arranged with cyclic symmetry. The natural modes of its vibration can be distinguished into the in-plane motion and the out-of-plane motion which are coupled by the gyro-effect due to the rotation of the gyroscope main body. The equations of motion, the response to angular velocities, and the relationships between the natural modes of vibration are derived and compared with the previous studies for the design of a micro three-axis ring gyroscope.

Effect of kinesio taping on gait function in elderly individuals with knee osteoarthritis: A pilot study

  • Park, Jaeyoung;Paik, Youngrim;Oh, Donghwan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1830-1833
    • /
    • 2019
  • Background: Knee osteoarthritis (OA) causes not only pain during walking but also walking disorders. Therefore, intervention for older patients with OA is important. Objective: To study investigated the effects of kinesio taping (KT) on pain and walking ability in elderly persons with knee OA. Design: One group, pre-post design Methods: This study enrolled 12 community-dwelling elderly people with knee OA. KT was applied on the surrounding structures, including the patellar and bilateral lateral ligaments. Assessment was made using the visual analog scale and GAITRite system to measure pain and walking ability during KT and non-KT conditions. Results: In this study, compared to the non-KT condition, the KT condition showed a significant improvement in walking ability and pain reduction during walking (velocity, cadence, step length, and stride length) (p < 0.05). Conclusion: This study demonstrated that knee KT has a positive effect on pain reduction and walking ability of the elderly with OA.

Conservative Management and Postoperative Rehabilitation of Chronic Lateral Ankle Instability (만성 외측 족관절 불안정성의 보존적 치료와 수술적 치료 후의 재활운동)

  • Park, Young Hwan;Kim, Hak Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.6-11
    • /
    • 2019
  • As a result of the increased participation in recreational and competitive sports activity, the incidence of chronic lateral instability has risen. Because chronic ankle instability can cause significant comorbidity and increase the social cost, the interest in this issue is growing. Although there are well-documented and effective surgical treatments for managing this condition, conservative treatments are a viable first option in selected patients. Through conservative treatment, surgical treatments can be reduced or delayed without necessarily affecting the overall outcome, but the failure of conservative treatment results in the need for surgical treatment to reduce the long term complications. Appropriate postoperative rehabilitation is essential for adequate functional recovery, even when surgical treatment is required.

Acute Anterior Talofibular Ligament Open Type Avulsion Fracture: A Case Report (전거비 인대의 개방성 견인 골절: 증례 보고)

  • Kang, Chan;Lee, Gi-Soo;Lee, Jung-Kil
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.170-172
    • /
    • 2018
  • An ankle sprain is a relatively common sports-related injury but a severe open ankle sprain (SOAS) is very rare. A 27-year-old female athlete was injured during running and was hospitalized because of an inversed ankle injury with an open wound. She was diagnosed initially with an open-avulsion fracture at the tip of the fibula with an anterior talofibular ligament tear. The patient was finally diagnosed with SOAS from the surgical findings and literature review. SOAS should also be considered if there is a transverse open wound at the time of an ankle injury.

Forearm Mechanism Inspired by Ligamentous Structure and Its Mobility Analysis (인대 구조에서 기인한 전완 메커니즘과 자유도 해석)

  • Lee, Geon;Lee, Ho
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.2
    • /
    • pp.209-215
    • /
    • 2022
  • In this paper, a forearm Mechanism design inspired by ligamentous structure of the human body is proposed. The proposed mechanism consists of four rigid bodies and fourteen wires without any mechanical joints. Actually, the mechanism is based on the concept of the tensegrity structure. Therefore, the proposed mechanism has inherently compliant characteristics due to the flexibility of the wires composing the structure. Rigid bodies and wires of the mechanism mimic bones and major ligaments in the forearm of the human. The proposed mechanism is classified as one of the interconnected hybrid flexure systems. The analysis method of the degree of freedom (DOF) of the proposed mechanism is also introduced through analyzing technique of the interconnected hybrid flexure systems, in this paper. Ultimately, the proposed mechanism, whose structure is complicated with rigid bodies and wires, mathematically drives that it has 3-DOFs.

Musculoskeletal Ultrasound Application in Cervical Spine: Pictorial Essay (경추부의 초음파 적용: 임상화보)

  • Yoon, Yong-Soon;Lee, Jung-Hoo;Kim, Eun-Sil;Lee, Kwang Jae
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.74-85
    • /
    • 2021
  • Ultrasound (US) can depict of various anatomical structures, such as muscles, tendons, ligaments, nerve roots, and vessels, around the neck. The usage of US around the neck is increasing due to its quick and easy application for guided injection for nerves, tendons, and joints. This article elaborates the degenerative diseases causing neck pain, sonoanatomy, and the use of US for diagnosis and intervention; for example, small nerves around the neck, cervical root, stellate ganglion, medial branches, greater occipital nerve (GON), and third occipital nerve (TON). The aim of this review article is to lead readers to understand the anatomy around the neck and structural relations, and to get to know about several US-guided intervention of the neck.

Analysis of droplet formation under sloshing phenomena in liquid fuel tank (액체 연료 탱크 내 슬로싱 현상에서의 액적 형성 분석)

  • Sungwoo Park;Jinyul Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.102-110
    • /
    • 2023
  • With the global shift from a carbon-based economy to a hydrogen-based economy, understanding the sloshing phenomenon and its impact on boil-off rate (BOR) in liquid hydrogen (LH2) tank trailers is crucial. Here, we analyze the primary breakup process under sloshing phenomena in a liquid fuel tank. We observe the growth of multiple holes on the sheet-like structures and the formation of ligament structures reminiscent of jet atomization. Through the extraction of three-dimensional liquid regions, we analyze the geometrical characteristics of these regions, enabling the classification of sheets, ligaments, and droplets. The present findings could contribute to understanding the breakup mechanism and hold potential for the development of strategies aimed at minimizing BOR.

Development of Flexible and Lightweight Robotic Hand with Tensegrity-Based Joint Structure for Functional Prosthesis (기능형 의수를 위한 텐스그리티 관절 구조 기반의 유연하고 가벼운 로봇 핸드 개발)

  • Geon Lee;Youngjin Choi
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • This paper presents an under-actuated robotic hand inspired by the ligamentous structure of the human hand for a prosthetic application. The joint mechanisms are based on the concept of a tensegrity structure formed by elastic strings. These rigid bodies and elastic strings in the mechanism emulate the phalanx bones and primary ligaments found in human finger joints. As a result, the proposed hand inherently possesses compliant characteristics, ensuring robust adaptability during grasping and when interacting with physical environments. For the practical implementation of the tensegrity-based joint mechanism, we detail the installation of the strings and the routing of the driving tendon, which are related to extension and flexion, respectively. Additionally, we have designed the palm structure of the proposed hand to facilitate opposition and tripod grips between the fingers and thumb, taking into account the transverse arch of the human palm. In conclusion, we tested a prototype of the proposed hand to evaluate its motion and grasping capabilities.

MR Imaging of the Perihepatic Space

  • Angele Bonnin;Carole Durot;Manel Djelouah;Anthony Dohan;Lionel Arrive;Pascal Rousset;Christine Hoeffel
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.547-558
    • /
    • 2021
  • The perihepatic space is frequently involved in a spectrum of diseases, including intrahepatic lesions extending to the liver capsule and disease conditions involving adjacent organs extending to the perihepatic space or spreading thanks to the communication from intraperitoneal or extraperitoneal sites through the hepatic ligaments. Lesions resulting from the dissemination of peritoneal processes may also affect the perihepatic space. Here we discuss how to assess the perihepatic origin of a lesion and describe the magnetic resonance imaging (MRI) features of normal structures and fluids that may be abnormally located in the perihepatic space. We then review and illustrate the MRI findings present in cases of perihepatic infectious, tumor-related, and miscellaneous conditions. Finally, we highlight the value of MRI over computed tomography.