• 제목/요약/키워드: life testing

검색결과 1,286건 처리시간 0.05초

초음파탐상법을 이용한 Double Edge Notch 선단의 균열발생에 관한 연구 (A Study on the Crack Initiation from Double Edge Notch Tips by Ultrasonic Testing)

  • 임창현;최용식
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.51-57
    • /
    • 1993
  • This study was done by ultrasonic testing. The proves used in this study were 5Z10$\times$10A70. The useful fatigue life of structural components is determined by the sum of the elapsed load cycles required to initiate a fatigue crack and to propagate the crack from subcritical size to critical dimensions. Thus, to predict the service life of many steel structures and to establish safe inspection intervals, an understanding of the Fatigue Crack Initiation and Fatigue Crack Propagation behavior in the steel is required. In the present study, the Fatigue Crack Initiation Life in SPS 5A steel was investigated by testing specimens having widely varying notch acuities. The variation in the notch acuity covered the range from notch root raidus 0.5mm to 2.5mm, and Fatigue Crack Initiation Life data were obtained in that range.

  • PDF

Varistor 의 ALT(Accelerated Life Testing) 설계 및 주 고장모드 분석 (A Study for Accelerated Life Testing and Failure Analysis of Chip Varistor)

  • 장우성;이준혁;이관훈;오영환
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2005년도 학술발표대회 논문집
    • /
    • pp.51-67
    • /
    • 2005
  • General chip SMD parts(chip resistance, chip capacitor, chip varistor etc.) are very wide sed electronics parts for IT units. But, failure modes are indistinct for these chip parts. In factory and field the failure modes are recognized to accidental failure mope caused by potential defect. In this paper used chip varistor ALT(Accelerate Life Test) test for verify general failure modes in chip SMD parts. Also the results are useful for general chip SMD ALT tests.

  • PDF

Approaching the assessment of ageing bridge infrastructure

  • Boller, Christian;Starke, Peter;Dobmann, Gerd;Kuo, Chen-Ming;Kuo, Chung-Hsin
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.593-608
    • /
    • 2015
  • In many of the industrialized countries an increasing amount of infrastructure is ageing. This has become specifically critical to bridges which are a major asset with respect to keeping an economy alive. Life of this infrastructure is scattering but often little quantifiable information is known with respect to its damage condition. This article describes how a damage tolerance approach used in aviation today may even be applied to civil infrastructure in the sense that operational life can be applied in the context of modern life cycle management. This can be applied for steel structures as a complete process where much of the damage accumulation behavior is known and may even be adopted to concrete structures in principle, where much of the missing knowledge in damage accumulation has to be substituted by enhanced inspection. This enhanced and continuous inspection can be achieved through robotic systems in a first approach as well as built in sensors in the sense of structural health monitoring (SHM).

제품(製品) 수명(壽命) 시험(試驗)의 응용(應用)과 확장(擴張) (Expansions and Applications of Item Life-time Testing)

  • 이창호
    • 품질경영학회지
    • /
    • 제11권1호
    • /
    • pp.10-17
    • /
    • 1983
  • 본 연구에서는 제품의 수명시험을 수행하는데 있어서 수명이 지수분포를 따를 때의 결과를 [1]제품의 MTBF가 $T_1$인 경우, 검사에 통과될 확률 $1-{\alpha}$(${\alpha}$는 생산자 위험), 제품의 MTBF가 $T_2$인 ($T_1$ > $T_2$) 경우, 검사에 통과될 확률 ${\beta}$(${\beta}$는 소비자 위험)로 하여 수명이 Weibull 분포(Shape Parameter를 알고 있을 때)를 따를 때에로 확장하였다. 또한, 수명시험과 관계있는 검사특성곡선(QC curve)과 평균수명시험시간(Average Life Testing Time)을 구해 보았다. 비용분석은 [1]의 과정을 그대로 활용하였다. 위의 전 과정은 Level II Basic Language로 Programming하여 Micro-Computer를 이용하여 계산하였다. 본 연구와는 다른 관점에서 Weibull 분포의 수명시험계획을 다루었던 [6]의 결과는 모두 같은 방향 - 지수분포에 비해 수명시험시간의 절감 - 으로 귀결되었음을 알 수 있다.

  • PDF

유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구 (Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type)

  • 도경훈;이석진;김종미;김성민
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구 (The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel)

  • 조의열;권기봉;조대형;김종렬
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.

정전위 전해식 가스센서의 가속수명시험법 개발 (Development of Accelerated Life Test Method for Constant Electrical Potential Electrolysis Gas Sensor)

  • 양일영;강준구;유상우;오근태;나윤균
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권3호
    • /
    • pp.180-191
    • /
    • 2016
  • Purpose: The purpose of this study was to develop the accelerated life test method for Constant Electrical Potential Electrolysis gas sensor (CEPE gas sensor). Methods: The parts and modules of CEPE gas sensor were analyzed by using Reliability Block Diagram (RBD). Failure Mode and Effect Analysis (FMEA) and Quality Function Deployment (QFD) methods were performed for each part to determine the most affecting stress factor in its life cycle. The long term testing was conducted at three different dry heat levels and the acceleration factor was developed by using Arrhenius relationship. Conclusion: The acceleration factor for CEPE gas sensor was developed by using FMEA, QFD, and statistical analysis for its failure data. Also qualification tests were designed to meet the target life.

가속수명시험을 이용한 RF SAW 듀플렉서의 수명예측 (Lifetime Prediction of RF SAW Duplexer Using Accelerated Life Testing)

  • 김영구;김태홍;강상기
    • 한국통신학회논문지
    • /
    • 제39A권10호
    • /
    • pp.616-618
    • /
    • 2014
  • 본 논문에서는 RF SAW 듀플렉서에 대하여 가속수명시험을 설계하고 수명예측방법에 대하여 제시하였다. 가속수명시험설계 시 가속스트레스는 RF 입력전력으로 정하고 삽입손실이 0.5[dB] 증가하는 기간을 듀플렉서의 수명으로 정의하였다. 듀플렉서의 수명예측결과는 $85^{\circ}C$ 주위온도와 30[dBm] RF입력전력에서 약 82,900시간으로 추정되었다.

Non-destructive Evaluation Method for Service Lifetime of Chloroprene Rubber Compound Using Hardness

  • Park, Kwang-Hwa;Lee, Chan-Gu;Park, Joon-Hyung;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • 제56권3호
    • /
    • pp.124-135
    • /
    • 2021
  • Evaluating service lives of rubber materials at certain temperatures requires a destructive method (typically using elongation at break). In this study, a non-destructive method based on hardness change rate was proposed for evaluating the service life of chloroprene rubber (CR). Compared to the destructive method, this non-destructive method ensures homogeneity of CR specimens and requires a small number of samples. Thermal accelerated degradation test was conducted on the CR specimens at 55, 70, 85, 100, and 125℃, and the tensile strength, elongation at break, and hardness were measured. The results of the experiment were compared to those of the accelerated life evaluation method proposed in this study. Comparing the analyzed lives in the high temperature region (70, 85, 100, and 125℃), the difference between the service lives for the destructive method (using the elongation at break) and non-destructive method (using the hardness) was approximately 0.1 year. Therefore, it was confirmed that the proposed non-destructive evaluation method based on hardness changes can evaluate the actual life of CR under thermally accelerated degradation conditions.