• 제목/요약/키워드: level gauge

검색결과 248건 처리시간 0.027초

VULNERABILITY OF KOREAN COAST TO THE SEA-LEVEL RISE DUE TO $21^{ST}$ GLOBAL WARMING

  • Cho Kwangwoo;Maeng Jun Ho;Yun Jong-Hwui
    • Proceedings of KOSOMES biannual meeting
    • /
    • 해양환경안전학회 2003년도 추계학술발표회
    • /
    • pp.219-225
    • /
    • 2003
  • The present study intends to assess the long-term steric sea-level change and its prediction, and potential impacts to the sea-level rise due to the 21st global warming in the coastal zone of the Korea in which much socioeconomic activities have been occurred. The analysis of the 23 tide-gauge data near Korea reveals the overall mean sea-level trend of 2.31 mm/yr.In the satellite altimeter data (Topex/Poseidon and ERS), the sea-level trend in the East Sea is 4.6mm/yr. Both are larger than those of the global average value. However, it is quite questionable that the sea-level trends with the tide-gauge data on the neighboring seas of Korea relate to global warming because of the relatively short observation period and large spatial variability. It is also not clear whether the high trend of altimeter data in the East Sea is related to the acceleration of sea level rise in the Sea, short response time of the Sea, natural variability such as decadal variability, short duration of the altimeter. The coastal zone of Korea appears to be quite vulnerable to the 21st sea level rise such that for the I-m sea level rise with high tide and storm surge, the inundation area is 2,643 km2, which is about $1.2\%$ of total area and the population in the risk areas of inundation is 1.255 million, about $2.6\%$ of total population. The coastal zone west of Korea is appeared to be the most vulnerable area compared to the east and south. In the west of the Korea, the North Korea appears to be more vulnerable than South Korea. In order to cope with the future possible impact of sea-level rise to the coastal zone of Korea effectively, it is essential to improve scientific information in the sea-level rise trend, regional prediction, and vulnerability assessment near Korean coast.

  • PDF

Measurement of the Engine Oil Deterioration of the Diesel Vehicle Using the Engine Oil Level Gauge (엔진오일 레벨게이지를 이용한 디젤 엔진의 오일 열화특성 측정)

  • Kim, Man Jae;Sin, Tae Ho;Lee, Sang Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제25권1호
    • /
    • pp.60-65
    • /
    • 2017
  • We designed and fabricated the engine oil monitoring sensor to measure engine oil deterioration through increased vehicle mileage. Since the condition of the engine oil can be affected by the state of the vehicle and its operating conditions, it should be directly measured and determined in every vehicle. The fabricated sensor has an aluminum parallel capacitor structure that measures capacitance related with the dielectric constant, which is one of the indices of oil deterioration. The size of the capacitor is small enough that it could be easily adapted on the oil level gauge without introducing any change in the design. The fabricated device is installed in the diesel engine to measure the change in capacitance accurately as the vehicle moved from 0 km (new engine oil state) to 11,364 km. The results showed the maximum value at around 5,000 km, and the values plateaued as mileage increased, corresponding with the measurement result of the TAN (Total Acid Number). Based on the results, the condition of the oil must be monitored regularly though oil change is recommended once the vehicle has traveled the distance of around 10,000 km.

A Study on the Effects of Relationship Between Copper Crusher Gauge and Internal Piezo Gauge (강내압력측정 신뢰성 확보 방안에 관한 연구: 동구게이지와 IPG 게이지 성능 비교 중심)

  • Jung, Min-Cheol;Lee, Jeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제21권9호
    • /
    • pp.120-127
    • /
    • 2020
  • This study examined the operation of a pressure gauge for measuring the internal pressure of a barrel. During the ammunition performance evaluation test, the internal pressure of the barrel was measured mainly using a copper crusher gauge. The internal piezo gauge (IPG) was used to replace the pressure measurement method, and the test results were analyzed to verify the operability of the IPG. For verification, actual shooting test data were used, and a t-test was used to analyze the results. The 155MM KH179 and M119 series propellant were used for the test equipment and ammunition. The results confirmed that there was no difference between the mean values of the two data results at a significance level of 5% for the data values between the copper gauge and the IPG. The use of the IPG was verified by replacing the existing copper gauge to measure the internal pressure of the barrel, and it was confirmed that the application width could be widened in terms of diversity of test measurement methods. Based on the results of this test, it can be applied to the compression measurement test of various types of ammunition in addition to the propellant charges.

The Analysis of the Correlation between Groundwater Level and the Moving Average of Precipitation in Kum River Watershed (금강유역에서의 지하수위와 강수량 이동평균의 상관관계 분석)

  • Yang, Jeong-Seok;Ahn, Tae-Yeon
    • The Journal of Engineering Geology
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2008
  • Precipitation and groundwater level data sets from Kum river watershed were analyzed and compared. The correlation between groundwater level and the moving average of precipitation was analyzed. Moving averaging technique is stochastic method and that was used to consider the effect of precipitation events on groundwater level fluctuation. Groundwater level generally follows seasonal precipitation pattern and low level occurs from early December to late April. Relatively high groundwater level is appeared in wet spell (July and August). The correlation between groundwater level and the moving average of precipitation to consider precedent precipitation events was analyzed with minimum two-year data sets. When the precipitation and groundwater level data set pair was selected the precipitation gauge station is closely located to groundwater level gauge station in the upstream direction to minimize the non-homogeneous precipitation distribution effect. The maximum correlation was occurred when the averaging periods were from 10 days to 150 days with Kum river watershed data. The correlation coefficients are influenced by data quality, missing data periods, or snow melt effect, etc. The maximum coefficient was 0.8886 for Kum river watershed data.

Preparation Technique of Foam-Floater to Level Gauge of LPG Tank with High Pressure (LPG 고압탱크 레벨 게이지(Level Gauge)용 발포부표 제조 기술)

  • Kim, Byoung-Sik;Hong, Joo-Hee;Chung, Yongjae;Heo, Kwang-Beom
    • Applied Chemistry for Engineering
    • /
    • 제17권4호
    • /
    • pp.361-368
    • /
    • 2006
  • The purpose of this study is to invent the preparation technique of the foam-floater used as a level gauge of liquefied petroleum gas (LPG) tank under high pressure, which has not only closed pores but also has under 5 wt% changingrate in case of depositing 72 h in room-temperature LPG. In pressure-resistance and deposition experiment, the prepared foam-floaters with different sulfur (325 Mesh and 400 Mesh) and foaming agent (dinitrosopentamethylenetetramin; DPT and azodicarbonamide; AC) had a marginal difference in its weight changing-rate. However, the prepared floater with sulfur 400 Mesh and the foaming agent AC had smaller pores and higher closed pore-rate. Under $50kg_f/cm^3$ hydraulic pressure, the floater with medium thermal (MT) carbon showed a lower weight changing-rate than semi reinforcing furnace (SRF) carbon. Providing a post-treatment to the prepared floater, the hardness and the pressure-resistance of the inner pore-wall of floater were increased. Prepared floaters having a specific gravity below 0.30 were distorted and broken, and other floaters with a specific gravity above 0.35 were not useful as a floater because of the low buoyancy. Therefore, it was considered that the floaters with a specific gravity between 0.3~0.35 are the most useful as a floater under $50kg_f/cm^3$ pressure-resistance.

Sea Level Variabilities in the East Asian Marginal Seas by Topex/Poseidon Altimeter Data (Topex/Poseidon 고도계자료를 이용한 동북아시아 연변해역의 해수면 변화 연구)

  • Yoon, Hong-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제5권6호
    • /
    • pp.1190-1194
    • /
    • 2001
  • The first 7 years of altimeter data from the TOPEX/POSEIDON(T/P) were analyzed to study the surface circulation and its variability in the East Asian Marginal Seas. Long term averaged T/P sea level time series data where compared with in situ sea level measurements from a float-operated type tide gauge around of south Korea and Japan. T/]P data are a large contaminated by 60-day tidal aliasing effect, very near the alias periods of M2 and 52. When this 60-day effect is removed, the data agree well with the tide gauge data with 4.6 cm averaged RMS difference. The T/P derived sea level variability reveals clearly the well-known, strong current-topography such as Kuroshio. The T/P mean sea level of North Pacific(NP) was higher than Yellow Sea(YS) and East Sea(ES). The T/P sea level variability, with strong eddy and meandering, was the largest in eastern part of Japan and this variability was mainly due to the influence of bottom topography in Kuroshio Extension area.

  • PDF

Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구)

  • 박준오;이준석;최일윤;민경주
    • Journal of the Korean Society for Railway
    • /
    • 제5권3호
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

Uncertainty Analysis of Spinning Rotor Gauge Calibrated by High Vacuum Standard of Static Expansion Method (정적법 고진공표준기에 의해 교정한 스피닝 로터 게이지 불확도 평가)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • 제14권4호
    • /
    • pp.186-194
    • /
    • 2005
  • A Spinning Rotor Gauge was calibrated between $4.04\times10^{-3}$ Pa and $1.11\times10^{-2}$ Pa at the high vacuum standard by static expansion method. The results were analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The expanded uncertainty was $3.0035\times10^{-3}$ Pa at $7.5448\times10^{-3}$ Pa. $95\%$ confidence level, and coverage factor of k = 1.

A Study on the Geometric Deformation Measurement of Structures by Collinearity Condition (공선조건에 의한 구조물의 기하학적 변형해석에 관한 연구)

  • 강준묵;오원진;이진덕;한승희
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제4권2호
    • /
    • pp.77-87
    • /
    • 1986
  • As for the deformation measurement of structure, there are many controversial points in using the methods by the strain guage, inclinometer, bial guage, and geodetic method because of the difficulty of instrument setting and the problem in the degree of accuracy of the results as well as in the economical aspect. Therefore, to verify the superiority of the Close- Range Photogrammetry method for the structural deformation measurement, the result of load deformation on the model structure, which was made using the Close-Range Photogrammetry method was compard with the results which was made using the methods of dial guage, precision level, and triangulation. In addition to that, to consider the general problem which would happen when C. R. P method was applied to the practical structure. The elements of C. R. P method like camera rotation angle ($\psi$,$\omega$), exposure elevation (Z$_{L}$), and angle of inclined base line ($\theta$) were experimented, and their specificities were reconsidered. As a result, the application of C. R. P method to the general structure is expected to be increased not only in the aspect of accuracy but in the economical aspect.t.

  • PDF

A Study on the Proper Installation of Storage Tank Measuring Instruments through a Case Study of Corrosive Fluid Leak Accident (부식성 유체 누출 사고사례 연구를 통한 저장탱크 레벨게이지 적정설치에 관한 연구 )

  • Sang Ryung Kim;Gyu Sun Cho;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • 제27권2호
    • /
    • pp.32-38
    • /
    • 2023
  • In a chemical plant, while supplying corrosive fluid to a storage tank with a pump, an accident occurred where the corrosive fluid leaked through the upper exhaust vent because the level indicator was not accurately determined. There are various causes of leakage accidents, but we focused on the sticking of the level indicator of the level gauge, which is the direct cause. As a result of the analysis, the level indicator used in the workplace where the accident occurred was randomly replaced, and in the summer when the accident occurred, the tubular type level gauge was found to be more likely to stick than other types because thermal expansion easily occurs. In addition, there were difficulties in reviewing the proper installation because the installation standards for measuring instruments installed in storage tanks were not clear in Korea. Therefore, in this study, based on accident cases and overseas standards, we are going to find out about precautions when installing storage tank instrumentation.