• Title/Summary/Keyword: lesion

Search Result 5,830, Processing Time 0.053 seconds

Comparison of Diagnostic and Post-therapy Radioiodine Scan in Well-Differentiated Thyroid Cancer and the Clinical Outcome (갑상선암 환자에서 방사성옥소 진단스캔과 치료 후 스캔의 비교 및 임상경과)

  • Lee, Seok-Mo;Bae, Sang-Kyun;Yum, Ha-Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose: We compared the first postoperative diagnostic and post-therapy scans of patients who received therapeutic doses of I-131, to investigate the difference in clinical outcomes between patients with concordant findings of diagnostic and post-therapy scans and patients with discrepant (more lesions in post-therapy scan) findings. Materials and Methods: The first postoperative diagnostic and post-therapy radioiodine scans of one hundred forty three patients with well differentiated thyroid carcinoma were reviewed. Diagnostic scans were obtained following ingestion of 185 MBq of I-131 and post-therapy scans were obtained after therapeutic dose of $3.7{\sim}9.3$ GBq of I-131. Successful ablation was defined as no radioiodine uptake on diagnostic radioiodine scan and normal range of serum thyroglobulin level (<10 ng/ml) during serum TSH elevation. Results: Discrepant scan findings were noted in 25 (17.5%) patients. Twenty-two patients (15.4%) showed more lesions in post-therapy scan and 3 patients (2.1%) showed stunning effect. Nine (64.3%) of 14 patients with distant metastasis revealed metastatic lesion(s) only on post-therapy scan. Stunning effect was considered as sublethal damage in 1 patient and treatment by a diagnostic dose in 2 patients. Ablation was achieved in 52.4% (75/143) of all patients. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. Conclusion: There were 17.5% difference between diagnostic and post-therapy scan findings when using 185 MBq of I-131 as a diagnostic dose. However, 64.3% of distant metastases were revealed only on post-therapy scan. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. The stunning effect was considered as not only sublethal damage but also treatment by a small diagnostic dose of radioiodine.

  • PDF

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Development of Disease-resistant Japonica Rice Varieties and Effects of Pyramiding Resistance Genes (내병성 자포니카 벼 계통 육성과 저항성 유전자 집적효과)

  • Kim, Woo-Jae;Baek, Man-Kee;Park, Hyeon-Su;Lee, Geon-Mi;Lee, Chang-Min;Kim, Seok-Man;Cho, Young-Chan;Seo, Jeong-Phil;Jeong, O-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.4
    • /
    • pp.314-326
    • /
    • 2020
  • This study was carried out to develop a resistant variety against the K3a race of bacterial blight, Xanthomonas oryzae pv. oryzae, through expansion and pyramiding of resistance genes. To develop an elite bacterial blight-resistant cultivar, the breeding process and bacterial blight resistance reactions in advanced backcross lines (ABLs) were analyzed. ABLs21 which contain Xa3 and Xa21, were developed by double backcrossing japonica cultivar Hwanggeumnuri, which has bacterial blight resistant Xa3 gene, and indica variety IRBB21, which havs Xa21 gene, followed by disease resistance bioassay and marker-assisted selection. The resistance genes of ABLs21 were amplified by PCR with the molecular markers 9643.T4 (Xa3) and U1/I1 (Xa21). Hwanggeumnuri and IRBB3 showed resistance reactions against K1, K2, and K3 races, and a susceptible reaction against K3a, K4, and K5 races. IRBB21 showed resistance reactions against K2, K3, K3a, K4 and K5 races, and a susceptible reaction against K1 race. Hwanggeumnuri showed susceptible reactions at the seedling, tillering and adult stages (all stages), whereas ABL21-1 showed moderate resistance at the tillering stage. ABL21-1 showed stable resistance against 18 isolates of K3a race, and the lesion length was shorter than that of the donor parents. In cluster analysis, the HB4032 isolate showed the highest pathogenicity among the 18 isolates. The molecular marker polymorphisms and average substituted chromosome segment lengths of ABLs21 were 63.2 % and 86.1 cM, respectively. Insertion of the donor chromosomal segments occurred in the predicted region of the Xa21 gene of ABLs21.

A New Screening Method for the Selection of Calla Lily Zantedeschia aethiopica Cultivars Resistant to Calla Lily Soft Rot (칼라의 무름병 저항성 품종 선발을 위한 검정 방법 개발)

  • Joung, Hyang Young;Choi, Mok Pil;Han, Kyung Sook;Kim, Su;Goo, Dae Hoe;Kang, Yun Im;Choi, Youn Jung;Park, Sang Kun
    • Horticultural Science & Technology
    • /
    • v.31 no.3
    • /
    • pp.366-370
    • /
    • 2013
  • This experiment was carried out to establish the screening methods for the selection of Zantedeschia aethiopica cultivars resistant to calla lily soft rot caused by Pectobacterium carotovorum subsp. carotovorum. A center of leaf and petiole tissues of four Z. aethiopica cultivars were wounded and inoculated with three different inoculum concentrations, $1{\times}10^7cfu/mL$, $1{\times}10^8cfu/mL$, and $1{\times}10^9cfu/mL$, of EccNHRI-21 isolate. And they were evaluated at 4, 18, and 26 hours after inoculation. The lesion of maceration was developed well in the leaf tissues inoculated with $1{\times}10^9cfu/mL$ concentration. And evaluation of resistance in 18 hours after inoculation was correlated with field resistance positively. Using this method, ten Z. aethiopica commercial cultivars and four wild types were screened. 'Crowbrough' and 'White Cutie' were selected as highly resistant genotypes and 'Mont Blanc' and 'Silky White' as resistant genotypes. 'Wedding March' and 'Kiwi Blush' were evaluated as moderate resistant and the others including 'Childsiana' were susceptible. And all of four wild types were evaluated as more than moderate resistant. In spite of control through cultural, biological and chemical methods, the use of resistant cultivars is most efficient to overcome calla lily soft rot. This newly developed screening method was helpful for breeding new varieties resistant to calla lily soft rot.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Human Papillomavirus Prevalence and Distribution according to Age among Korean and Chinese Women (중국과 한국여성에서 나이에 따른 인유두종바이러스의 유병률과 분포)

  • Kim, Geehyuk;Kim, Sunghyun;Park, Sunyoung;Park, Sangjung;Lin, Han;Ren, Yubo;Li, Yingxue;Lee, In Soo;Lee, Jae Dal;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.259-266
    • /
    • 2015
  • Cervical cancer is the third most common cancer among women worldwide. Cervical cancer is significantly associated with human papillomavirus (HPV) infection. The prevalence of HPV infection is influenced by geography, immune status, sexual history and genetic factors. For example, geographically, HPV prevalence varies from 1.5% to 39%. However, little is known about the relationship between HPV prevalence and age. An analysis of HPV prevalence by age will help determine when high-risk groups are exposed to HPV. Such an analysis could also demonstrate a correlation between specific HPV genotypes and age. In addition, the analysis might clarify the optimum age for using vaccines. In this study, HPV prevalence and genotype distribution among Korean and Chinese women are analyzed by age. The REBA HPV-ID$^{(R)}$ assay (YD diagnostics, Yong-in, Republic of Korea) was used for detecting HPV genotypes in uterine cervical liquid-based cytology samples from 533 women from Korea and 324 from East China (Western Shandong province. Women with severe dysplasia such as SCC (Squamous cell carcinoma) and HSIL (High-grade squamous intraepithelial lesion) groups were primarily in their 40s and 50s, whereas women with mild and moderate dysplasia (ASCUS and LSIL groups) were primarily in their 30s and 40s. Women with HPV genotype 16 and 18 infections were primarily in their 40s. The results suggest that HPV infection is associated with certain age groups in the Korean population.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

The Effects of Sahyangsohapwon on the Affective Reactivity and the Acquisition of Two-way avoidance in AD Model Rats (사향소합원(麝香蘇合元)이 정서반응성(情緖反應性)과 Alzheimer's disease 모델 백서(白鼠)의 학습(學習)에 미치는 영향(影響))

  • Hong Dae-Sung;Kim Jong-Woo;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.10 no.1
    • /
    • pp.17-38
    • /
    • 1999
  • The effects of Sahyangsohapwon on the affective reactivity of rats were studied with open-field behavior. Sample group was treated with the medicine for 8 weeks, whereas control group was treated with the vehicle. The effects of Sahyangsohapwon on the enhancement of learning and memory of AD model rats were studied with two-way avoidance task. Sample group electrically lesioned on nbM(nucleus basalis of Meynert) was treated with the medicine for 8 weeks, whereas control group with nbM lesion and sham group with the sham operation were treated with the vehicle. 1. In the open-field behavior task, the start latency from start box was measured $27.08{\pm}7.51sec$ in control group, $23.15{\pm}5.98sec$ in sample group. Rats in sample group showed a tendency of shortened latency going out to a strange place compared with those in control group, but with no statistical significance(p>0.05). 2. In the open-field behavior task, the number of locomotion crossing the grid lines was measured $84.54{\pm}3.55$ in control group, $116.93{\pm}6.41$ in sample group. There was an increased locomotion in sample group compared with control group with statistical significance(p<0.01). This can be interpreted as rats in sample group showed lowerd anxiety under a strange environment. 3. In the open-field behavior task, the rearing number was measured $7.46{\pm}0.57$ in control group, $10.13{\pm}0.95$ in sample group. There was an increased rearing in sample group compared with control group with statistical significance(p<0.05). This can also be interpreted as rats in sample group showed lowerd anxiety under a strange environment. 4. In the open-field behavior task, the number of crossing behavior was measured $5.54{\pm}1.50$ in control group, $9.20{\pm}1.67$ in sample group. There was a increasing tendency of crossing behavior in sample group compared with control group, but with no statistical significance(p<0.05). 5. In the open-field behavior task, the total activity was measured $97.54{\pm}4.70$ in control group, $136.27{\pm}792$ in sample group. There was an increased total activity in sample group compared with control group with statistical significance(p<0.01). This can also be interpreted as rats in sample group showed lowerd anxiety under a strange environment. 6. In the analysis of effects on the learning and memory in AD model rats with two-way avoidance task, the response latency was measured $6717{\pm}134msec$ in the 1st session, $5416{\pm}160msec$ in the 2nd session, $5252{\pm}148msec$ in the 3rd session in control group. It was measured $6724{\pm}155msec$ in the 1st session, $4642{\pm}139msec$ in the 2nd session, $4914{\pm}148msec$ in the 3rd session in sample group and $4357{\pm}144msec$ in the 1st session, $3125{\pm}115msec$ in the 2nd session, $3091{\pm}98msec$ in the 3rd session in sham group. There were differences between sham group and nbM lesioned groups with statistical significance in post hoc analysis(p<0.000). And in the 2nd session, there was a reduction of latency in sample group compared with control group with statistical significance (p<0.000). This showed that sample group had better learning capacity than control group. 7. In the analysis of effects on the learning and memory in AD model rats with two-way avoidance task, the number of avoidance response was measured $5.85{\pm}1.41$ in the 1st session, $14.23{\pm}2.89$ in the 2nd session, $15.69{\pm}2.56$ in the 3rd session in control group. It was measured $7.92{\pm}1.94$ in the 1st session, $16.83{\pm}2.29$ in the 2nd session, $15.42{\pm}2.81$ in the 3rd session in sample group and $14.38{\pm}1.62$ in the 1st session, $22.88{\pm}0.89$ in the 2nd session, $23.88{\pm}1.64$ in the 3rd session in sham group. There were differences between sham group and nbM lesioned groups with statistical significance in post hoc analysis(p<0.001). But between control and sample group, there was no significant difference. With the experimental results above, Sahyangsohapwon can be supposed to have the enhancing effects on the affect reactivity and learning with memory of AD model rats induced by electrolyte injury of nbM.

  • PDF