• Title/Summary/Keyword: lens control

Search Result 357, Processing Time 0.028 seconds

A Study of Auto Focus Control Method for the Mobile Phone Camera (이동단말기 카메라 자동 초점 조절 방식에 관한 연구)

  • Kim, Gab-Yong;Kim, Young-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.1003-1006
    • /
    • 2005
  • Demand of Auto Focus for Camera module is increased very fast in these days and will be adapted to most of mobile phones in next few years instead of traditional method, fixed focus. To make auto focus function, 2 kinds of solutions, VCM(Voice Coil Motor) and Piezo linear motor are normally used. In this paper, VCM which commercially strong candidate for Auto focus mechanism was investigated to verify principles are match up to the actual operation. Auto focus algorithm is different between 1 chip and 2 chip solution. Normally 2 chip is more complicate than the other. To have best performance on this function, hysteresis and depth of field(DOF) table should be optimized.

  • PDF

Empirical Modeling of Lens Distortion in Change of Focal Length (초점거리 변화에 따른 렌즈 왜곡의 경험적 모델링)

  • Jeong, Seong-Su;Woo, Sun-Kyu;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.93-100
    • /
    • 2008
  • The parameters of lens such as focal length, focus, and aperture stop changes while shooting the scenes with zoom lens. Especially, zooming action dramatically changes the geometry of lens system that causes significant change of lens model. We investigated how the lens model changes while zooming in general shooting condition. Each parameters of lens model was estimated and checked whether they can be modeled well in the condition of auto-controlling focus, aperture and vibration reduction. In order to do this, calibration images were taken, modeled in different fecal length setting. And changing patterns of models were inspected to find out if there is some elements that have some particular pattern in changing with respect to focal length. The result showed us that although we didn't control the focus and aperture setting, there's specific changing patterns in radial and do-centering distortion. Especially, the strong linear correlation was found between coefficient of $r^2$ and focal length. It is expected that many parts of distortion can be eliminated without additional self calibration even if zoom operation is done when shooting the scenes if we know its fecal length and model of this coefficient.

UV-cut Lens Manufacture using Optical Absorption Edge Control (광흡수단을 제어를 이용한 UV 차단렌즈 개발)

  • Kim, Yong Geun;Park, Dong Hwa;Sung, Jung Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 2002
  • Because do dilution (5%) in Venzotriazol distilled water and is kept UV interception departure woe which make to time each 1, 2, 5, 15, 20, 30 minutes by dip method, produced sample ore of UV interception lens. Spectrum of transmittance for each sample are measured in 320~450nm sacred grounds. The result optical absorption edge is each 403, 408, 414, 419nm regions, and absorption edge appeared in each band of 3.07, 3.04, 2.99, 2.96 eV. UV-cut lens departure solution make 2-Hydroxy-4-n-octoxyhenzophenones of 5%, 10% because solvent methanol and UV-cut lens made by Spray pyrolysis method. Transmission edge of each lens that do spray to same warelength showed sameinwavelength spectra. Being storehouse absorption edgethat increase 385, 398 and 417nm region of when do spray for 2, 4 and 6 minutes, band is accomplishing each 3.22, 3.11, 2.97 eV.

  • PDF

A Study on Molding Condition of Aspheric Glass Lenses for Mobile Phone Module Using Design of Experiments ; Pressing Condition (DOE를 적용한 카메라폰 모듈용 비구면 Glass렌즈의 성형조건 연구 ; 가압조건)

  • Cha, Du-Hwan;Lee, Jun-Key;Kim, Sang-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.57-57
    • /
    • 2007
  • Aspheric glass lenses have many optical advantages, for glass have superior optical performance and an aspheric form can reduce optical aberrations. Recently, the use of it is rapidly expanding as the mass production becomes possible by glass molding press and so this method is considered as the best method for fabricating an aspheric glass lens, but it is difficult to control many parameters for pressing and cooling process. Design of experiments (DOE) is a very useful tool to design and analyze complicated industrial design problems. This study investigated the pressing conditions to mold aspheric glass lenses for mega pixel phone camera module using DOE method. We have applied fractional factorial design and the response variable was set form accuracy (PV) of aspheric surface of molded lens. The results of analysis indicates that all factors expect for pressing force of each step are available for the form accuracy (PV). It was the optimum condition of the designed pressing conditions for lowering the form accuracy(PV) value of molded lens that all factors were at the low level. The form accuracy (PV) of mold and molded lens under the optimum condition are $0.85\;{\mu}m$ and $0.922\;{\mu}m$ respectively.

  • PDF

A Study on Antioxidant System in Cataract Patients (한국인 백내장환자의 항산화 체계에 관한 연구)

  • 고영숙;홍영재;정혜연;김수연;이양자
    • Journal of Nutrition and Health
    • /
    • v.35 no.2
    • /
    • pp.229-236
    • /
    • 2002
  • Cataracts are the leading cause of blindness worldwide and are characterized by increased opacity of the lens that significantly diminishes visual acuity. It has been suggested that increased risk of lens opacities are associated with age, exposure to sunlight, diabetes, smoking, and poor nutrition. Antioxidant nutrients have born demonstrated to protect the lens membrane and protein against damage due to oxidative stress. The purpose of this study was to investigate the antioxidant system in the blood of cataract patients. The status of the blood antioxidant system was evaluated based on the levels of antioxidant vitamins and minerals as well as glutathione peroxidase (GSH-Px) and malondialdehyde (M7A) activity in 34 patients with cataracts (17 male and 17 female) and 45 control subjects (20 male and 25 female). After adjusting for age, the results showed significantly lower levels of antioxidant vitamins such as lycopene (M : p < 0.05, F: p < 0.01), zeaxanthin (F: p < 0.01), ${\gamma}$-tocopherol (F: p < 0.01) and ascorbic arid (M: p < 0.05) in the cataract patients than in the control subjects. In contrast, the concentration of cryptoxanthin (F : p < 0.07) showed a significantly higher value in the cataract patients. The serum level of the antioxidant mineral Zn (M : p < 0.01) was found to be significantly lower in the cataract patients while the ratio of cu/zn appeared significantly higher (M : p < 0.05). Significantly higher (M : p < 0.01, F: p < 0.05) concentrations of MDA in serum was found in the cataract patients as compared to the control subjects. GSH-Px activity was significantly lower (F: p < 0.05) in 71e cataract patients. In conclusion, the antioxidant system may play an important roll in cataract creation. Further studies are needed to clarify the mechanisms underlying these findings and to establish preventive measures with an emphasis on antioxidant nutrition for cataract patients.

Improvement Air Gap Control for SIL based Near-Field Recording System (SIL을 이용한 근접장 기록계에서의 서보 방식의 개발)

  • Kim, Joong-Gon;Kim, Tae-Hun;Jeong, Jun;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2007
  • A high density optical data storage device has been required for many years. In the field of the optical data storage, a near-field recording (NFR) technology is considered as a next generation one for achieving the high data density. Due to an evanescent wave effect occurred under 100nm distance which is the excessively small distance between the SIL and the disc, the most significant and difficult problem in this technology is to maintain a gap between a solid immersion lens (SIL) and a disc. Also, maintaining the gap under at least 50nm is required in the NFR gap servo system to use the evanescent wave effect efficiently. There are some institutes that have shown the novel gap servo control. In general, they use a mode switching servo method which consists of approach, hand-over and gap control mode. However there is a critical problem such as an overshoot at the tuning point from the approach mode to the hand-over mode, which may cause a collision between the SIL and the disc. In this paper, we show our NFR system and an improved gap servo system using an exponential function as the approach mode which can reduce the overshoot.

  • PDF

Quantifying Inhibitory Effects of Reclaimed Soils on the Shoot and Root Growth of Legume plant Lentil(Lens culinaris) (정화 처리토가 렌틸(콩과식물)의 지상부 및 뿌리 성장에 주는 영향에 대한 정량평가)

  • Park, Hyesun;Kang, Sua;Bae, Bumhan
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • A series of pot experiments were conducted to quantitatively estimate inhibitory effects of reclaimed soil on the growth of Lentil (Lens culinaris) with two soils remediated by land farming (DDC) and low temperature thermal desorption(YJ), respectively. After cultivation in a growth chamber for 8 days, plants were harvested for the analysis of 8 indices including chlorophyll-a and carotenoid in leaves, shoot fresh weight, root dry weight, root length, number of later roots, specific root length (SRL) as well as germination rate in comparison to control experiment conducted on nursery soil. Root length was estimated by SmartRoot program from the digital images of the roots. The results showed germination rate on YJ and DDC soil decreased 29 and 71%, respectively. In comparison to the control, the averaged value of the 8 indices for YJ and DDC soil showed overall growth inhibition was 48 and 68%, respectively. When the same experiment was conducted with 25% (W/W) vermiculate amended soil, plant growth on each soil was comparable to that of the control. The results implies reclaimed soils requires additional processes and/or amendments to reuse for plant growth.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

A Study on Hygienic Control of contact lens Storage case (콘택트렌즈의 저장 케이스의 위생관리에 관한 연구)

  • Shin, Jae Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.33-42
    • /
    • 2000
  • This study was conducted for 356 customers coming to N optometrist office in Masan city in order to evaluate practice of hygienic control of contact lens storage cases. The results were as follows: 1) For disinfection of contact lens storage case, students used wetting saline solution(42.6%), exclusive wetting solution(23.0%) and 21(11.5%) of them didn't practice disinfection. Others besides students used wetting saline solution(29.1%), boiling water(27.3%) and 42(25.5%) of them didn't practice disinfection(P<0.01). 2) For storage case washing solution, 18(85.7%) out of 21 people who belong to high economic class used wetting saline solution, 3(14.3%) used exclusive wetting solution, 141(48.0%) out of 294 people who belong to middle economic class used wetting saline solution, 129(43.9%) used exclusive solution(P<0.01). 3) For wetting solution of storage case, 132(74.6%) out of 177 students used exclusive wetting solution and the rest(25.4%) used wetting saline solution, 102(64.2%) out of 159 others besides students used exclusive wetting solution, 51(32.1%) used wetting saline solution and 6(3.8%) used sold water and city water(P<0.05). 4) 66(94.3%) out of 70 contact lens storage cases were contaminated by bacteria and Serratia marcescens was isolated in 33(47.1%) out of 70 contact lens storage cases.

  • PDF