• 제목/요약/키워드: length measuring

검색결과 1,159건 처리시간 0.026초

Mathematical modeling of concrete beams containing GO nanoparticles for vibration analysis and measuring their compressive strength using an experimental method

  • Kasiri, Reza;Massah, Saeed Reza
    • Advances in nano research
    • /
    • 제12권1호
    • /
    • pp.73-79
    • /
    • 2022
  • Due to the extensive use of concrete structures in various applications, the improvement of their strength and quality has become of great importance. A new way of achieving this purpose is to add different types of nanoparticles to concrete admixtures. In this work, a mathematical model has been employed to analyze the vibration of concrete beams reinforced by graphene oxide (GO) nanoparticles. To verify the accuracy of the presented model, an experimental study has been conducted to compare the compressive strengths of these beams. Since GO nanoparticles are not readily dissolved in water, before producing the concrete samples, the GO nanoparticles are dispersed in the mixture by using a shaker, magnetic striker, ultrasonic devices, and finally, by means of a mechanical mixer. The sinusoidal shear deformation beam theory (SSDBT) is employed to model the concrete beams. The Mori-Tanaka model is used to determine the effective properties of the structure, including the agglomeration influences. The motion equations are calculated by applying the energy method and Hamilton's principle. The vibration frequencies of the concrete beam samples are obtained by an analytical method. Three samples containing 0.02% GO nanoparticles are made and their compressive strengths are measured and compared. There is a good agreement between our results and those of the mathematical model and other papers, with a maximum difference of 1.29% between them. The aim of this work is to investigate the effects of nanoparticle volume fraction and agglomeration and the influences of beam length and thickness on the vibration frequency of concrete structures. The results show that by adding the GO nanoparticles, the vibration frequency of the beams is increased.

AR 플랫폼을 사용하지 않는 실제 방 기반 인테리어 시뮬레이션 연구 (A Study on Interior Simulation based on Real-Room without using AR Platforms)

  • 최규석;김준건;임창묵
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.111-120
    • /
    • 2022
  • 가구는 실내에서 다른 구조물과 잘 어울리는지 확인하는 것이 구매결정에 있어서 필수적이며 COVID-19 사태로 인한 언택트 마케팅 상황에서는 더욱 중요한 요소가 되고 있다. 이에 따라 가구 배치 인테리어 시뮬레이션을 위해 ARCore, ARKit 등 AR(Augmented Reality) 오픈 소스의 등장으로 AR을 이용한 길이 측정법이 등장하고 있는 추세이다. AR를 이용하는 이러한 기존 방식은 평면 카메라 이미지를 토대로 깊이 맵(Depth Map)을 생성하고 복잡한 입체화 연산이 수반되는 방식이라 스마트폰을 사용하여 정확한 실내 크기 정보가 요구되는 작업에서는 한계가 드러난다. 본 논문에서는 ARCore, ARKit 사용 없이 스마트폰에 내장된 가속도 센서, 자이로스코프 센서만으로 정확한 실내 크기를 측정하는 방법을 제안한다. 또한 제시된 기법을 이용한 활용 예제로 미리 디자인된 방 인테리어를 각방에 맞게 적용하는 방법을 제시하였다.

Effect of Uneven Surface Gait Training on Ankle Muscle Activation and Balance in Stroke Patients

  • Ji, Young-Ho;Lee, Jae-Kwang;Lee, Jong-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • 제34권4호
    • /
    • pp.161-167
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effects of regular training on the uneven surface that stroke patients encounter in their daily life on their ankle joint muscle activity and balance ability. They were divided into two groups: the gait training group on uneven surfaces and the gait training group on normal surfaces. Methods: In this study, 30 patients diagnosed with stroke and undergoing rehabilitation were selected. 15 people in the uneven surface gait training group and 15 people in the flat gait training group were selected. The muscle activation of the ankle muscles was measured when walking again on a even surface after walking on an uneven surface and on a flat ground. After each gait training, the limit of stability and Romberg test were performed to evaluate the balance ability. Results: As a result of the experimental results before and after walking by group, the tibialis anterior muscle activity of the paralyzed side was significantly decreased in the uneven surface walking group. As a result of measuring balance ability after training, the limit of stability in all directions was significantly increased in the uneven surface gait training group, and the area and length moved significantly decreased in the uneven surface gait training group in the Romberg test as well (p<0.05). Conclusion: After walking on uneven surface, it was confirmed that the muscle activity of the ankle joint decreased in normal flat walking, and thus the efficiency of muscle activity was increased. In addition, it was possible to confirm the improvement of the balance ability of the gait training on the uneven surface, and in conclusion, it could be confirmed that it had an effect on the improvement of the walking ability.

Radiographic Evaluation of Vertebral Heart Scale and Caudal Vena Cava Size Useful for Diagnosing Cardiac Diseases in Endangered Long-Tailed Goral (Naemorhedus caudatus)

  • Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Chea-Un Cho;Sooyoung Choi;Jong-Taek Kim
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.119-123
    • /
    • 2023
  • Although various imaging evaluation methods have been developed and utilized, thoracic radiography remains essential and is the top priority for diagnosing and managing cardiac diseases. Thoracic radiographic measurements associated with the vertebral heart scale (VHS) and caudal vena cava (CVC) can objectively diagnose cardiac disease in many animals. In particular, VHS measurement is primarily used to evaluate the dimensions of the heart size on thoracic radiographs and can measure cardiomegaly more objectively. Additionally, the value of the CVC compared with the aorta (Ao) and the length of vertebrae (VL) can be used as valuable parameters in right congestive heart failure. To describe the CVC/Ao and CVC/VL ratios in 10 long-tailed gorals (Naemorhedus caudatus) without subjective radiographic evidence of cardiac diseases. The VHS, CVC, Ao, and VL of gorals were measured in the right lateral (RL) view of the thoracic radiographs. In the RL view of 10 gorals, the VHS was 9.31 ± 0.55 vertebrae (v), the CVC/Ao ratio was 0.84 ± 0.13, and the CVC/VL ratio was 0.67 ± 0.09. Additionally, the thoracic morphology of gorals was determined to be intermediate (thoracic depth-to-width ratio, 1.04 ± 0.09, 0.75-1.25). This study confirmed that VHS was significantly correlated with CVC and Ao, and measuring and comparing each value would help diagnose cardiac diseases in gorals. The radiographic measurements in this study will allow veterinarians to diagnose several cardiac diseases in gorals.

The Effect of Induced Weight Bearing Method Using a Cane on Weight Bearing Distribution in Children with Spastic Hemiplegic Cerebral Palsy

  • Se-Hee Park;Ji-Young Choi;Sung-Min Son
    • The Journal of Korean Physical Therapy
    • /
    • 제35권2호
    • /
    • pp.48-52
    • /
    • 2023
  • Purpose: This study was undertaken to determine whether the position of cane use affects the distribution of weight-bearing on both feet of children with hemiplegic cerebral palsy in a standing posture. Methods: Twenty participants with cerebral palsy were recruited as volunteers for this study. Using the Zebris FDM-System, weight-bearing distribution according to the method of using a cane was measured under three conditions in randomized order: (1) standing unaided (no cane); (2) standing with the affected side using the cane; and (3) standing with the non-affected side using the cane. The cane was matched by measuring length-from-floor to the greater trochanter of the subject, and was placed 15 cm outward from the little toe on the supporting side. Results: Evaluating the method of using a cane under the three conditions, we determined that pressure of the foot on the affected side was higher in the order: standing with affected side using cane > standing unaided (no cane) > standing with non-affected side using cane (p<0.05). In the post-hoc analysis, a significant difference was observed between (i) standing unaided (no cane) and standing with the affected side using cane, and (ii) standing with affected side using cane and standing with non-affected side using cane (p<0.05). Conclusion: This study suggests that induced weight-bearing methods using a cane on the affected side could increase the weight-bearing capacity on the affected side in children with spastic hemiplegic cerebral palsy, which will have a positive effect on reducing asymmetry weight support.

호박의 손쉬운 품질 평가를 위한 건물율 측정방법 이용 (Measuring Total Solids Quantity as Easy Method for Quality Evaluation of Squash Fruits)

  • 홍규현;우영회;허윤찬
    • 현장농수산연구지
    • /
    • 제11권1호
    • /
    • pp.173-179
    • /
    • 2009
  • 부식용 채소로 이용되는 호박의 과실 품질을 손쉽게 측정할 수 있는 방법을 제시하고자 실험한 결과는 다음과 같다. 1. 호박의 식미와 가장 관련이 갚은 성분 중 하나가 총고형물의 양으로, '풋호박'과 '서울마디호박'의 과실내 총고형물이 각각 6.4 및 7.5%이었고 'Ford Zucchini'와 시판 '쥬키니' 품종은 각각 4.7 및 4.3%로 나타나 관능검사로 조사한 식미의 선호도 정도와 거의 일치하였다. 2. 분리세대에서 초장과 과실 품질 관련형질과의 상관관계가 없음을 알 수 있어, 초장이 짧은 우수 계통을 육성하는 것이 어렵지 않음을 알 수 있었다. 3. 호박 과실을 건조시킨 후 무게를 측정하는 간이측정법으로 식미 품질을 파악할 수 있어, 호박을 재배하면서 손쉽게 품질을 평가할 수 있는 방법으로 활용될 것으로 생각된다.

A Study on the single crystal growth of the optic-grade $LiTaO_3$ as a electro-optic materials

  • Kim, B.k.;J.K. Yoon
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.526-526
    • /
    • 1996
  • The single crystal of LiTaO3 is well known eletro-optic material as well as the piezoelectric one applied to SAW filter. LiTaO3 has large electro-optic effects, so applied to optical switch, acosto-optic deflector, and optical memory device using photorefractive effects. The crystal growth of SAW-grade LiTaO3 has been studied many aspects, but there is no detail research about optic-grade crystal growth. The conditions of optic-grade LiTaO3 single crystal are as below. The optical transmittance must be over 75%, and axial and radial concentratiom uniformity below 1%. The variation of Curie temperature depending on Li/Ta ratio must be also below 2$^{\circ}C$ and no internal no internal cracks and defects. Because of the limitation of crystal quality, the growing of optic-grade LiTaO3 single crystal is very difficult compared with the growing of SAW-grade. In this research, upper conditions of optic-grade single crystal was investigated after growing of 1 inch diameter and 1.5 inch length LiTaO3 single crystal having no internal cracks and defects using Czochralski method. Curie temperature was determined with DSC and measuring capacitance and lattice parameter was calculated about the grown crystal and ceramic powder samples of various Li/Ta ratio. The result of Tc variation was below 1.2$^{\circ}C$ all over the grown crystal, so it is confirmed that LiTaO3 was grown under congruent melting composition having optical homogeniety. Also, the optical transmittance was about 78%, which was sufficient for optical device.

  • PDF

일개 대학병원 내과 병동 입원환자의 전자의무기록에 사용된 통증간호 기록 분석 (Analysis of Pain Records Using Electronic Nursing Records of Hospitalized Patients in Medical Units at a University Hospital)

  • 박인숙;장미;유순애;김희진;오필주;정희정
    • 임상간호연구
    • /
    • 제16권3호
    • /
    • pp.123-132
    • /
    • 2010
  • Purpose: This study was done to analyse nursing records to identify the nature of pain and actual conditions of pain management in patients hospitalized in one university hospital. Methods: The participants in this study were 783 patients with a length of stay of 3 to 30 days who were discharged from medical wards between June 1 and June 30, 2009. Data on nursing records related to pain management from these patients were reviewed using the Electronic Nursing Records (ENRs) system. Results: Over 30 percent of 10,702 nursing records related to pain assessment had no record on region, severity, nature or frequency of pain. About 30 percent of 13,638 nursing records related to pain intervention showed non-drug pain management techniques. Conclusion: Accurate and complete records on pain assessment including region, severity, nature and frequency of pain are essential to effectively manage patients' pain. Improvement in ENRs system for better assessment and management of pain is required as well as education programs on a standardized measuring tool for both nurses and patients.

Reliability and Validity of Balancia 2.5 Program Using Wii Balance Board for Assessment of Static Balance Ability

  • Ho Kim;Dong-Min Kum;Won-Seob Shin
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.488-492
    • /
    • 2022
  • Objective: The purpose of this study is to find out the reliability and validity of the newly updated Balancia 2.5 program using Wii balance board through equipment that can measure center of pressure data with the precision. Design: Cross-sectional study Methods: Twenty-seven healthy adults participated in the study. The subjects were assessed for static balance ability by Accusway, and were assessed for static balance ability on Wii balance board connected to theBalancia 2.5 program.To limit postural fluctuations due to stare, the subjects were asked to look at a 15 cm dot drawn 3 m in front of them for 30 seconds with their eyes open. Static balance ability data such as path length and sway velocity were extracted from all measurement tools.Intra-rater and inter-rater reliability and validity were extracted through intraclass correlation coefficient (ICC) and 95% confidence interval (CI). Results: The intra-rater reliability that the same rater shows consistent results through test-retest was a high level at ICC=0.968 (0.926~0.986), and inter-rater reliability that the requires consistent results even when measured by different raters was a high level at ICC=0.943 (0.870~0.975). The validity was a high level at ICC=0.948 (0.881~0.977), which shows whether the measurement tool is properly measuring what it is intended to measure. Conclusions: The Balancia 2.5 program, newly updated through this study, proved to be a program with high reliability and validity in evaluating static balance ability like the existingBalancia 2.0 program.

인공지능 기반 어류 분류 및 무게 추정 시스템에 관한 연구 (A Study on the AI-based Fish Classification and Weight Estimation System)

  • 고준혁;오동협;이지원;임태호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.229-232
    • /
    • 2022
  • 최근 우리나라 연근해어업 생산이 줄어들고 있다. 2016년도 연근해어업 생산량이 44년 만에 100만톤 이하로 내려간 이후 회복이 되지 않고 줄어들고 있다. 이와 같은 수산자원 감소에 대응하기 위해 국제적으로 수산자원관리를 위하여 TAC(총허용어획량) 제도를 시행하고 있다. 우리나라는 1999년부터 TAC 제도를 도입하여 자원관리를 수행하고 있다. 본 논문에서는 TAC 제도 시행을 위해서 필수적인 육상 옵서버의 수산자원 조사에 활용이 가능한 인공지능 기반 어류 분류 및 무게 추정 시스템을 제안한다. 이 시스템은 라이다 센서가 탑재된 단말기를 이용하여 어류의 체장, 체고를 자동 측정 및 사진 촬영을 수행하는 앱과 클라우드 서버로 구성된다. 클라우드 서버에는 CNN 기반의 efficientnet 모델을 이용하여 어류 분류를 수행하고 자동 측정된 체장, 체고 정보를 이용하여 어류의 무게를 예측한다. 본 시스템을 이용하면 기존에 육상 옵서버가 위판장에서 줄자와 무게 측정 후 수기로 작성하는 기존 방식을 개선할 수 있다.

  • PDF