• Title/Summary/Keyword: length measuring

Search Result 1,158, Processing Time 0.024 seconds

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

The Development of the Components of the Length Measurement Concept in the Procedure of Measurement Using a Ruler

  • Antic, Milica D.;Dokic, Olivera J.
    • Research in Mathematical Education
    • /
    • v.22 no.4
    • /
    • pp.261-282
    • /
    • 2019
  • The research related to testing pupils' achievement in the field of Measurement and Measure in initial teaching of geometry points to an insufficient adoption of the basic components of the length measurement concept among pupils. In order to discover the cause, we looked at the basic components on which the procedure of measuring length using a ruler is based, highlighted the possibilities of introducing the procedure in measuring length, and determined pupils' achievement during the procedure of measuring length using a ruler. The research sample consisted of 145 pupils, out of which 72 were the 2nd grade pupils and 73 were the 4th grade pupils. A descriptive method was applied in the research. The technique we used was testing, and for the statistical data processing we used a χ2 test. The results of the research show that, when drawing a straight line of a given length using a ruler, there is no statistical difference in achievement between the 2nd and 4th grade pupils, nor in the pupils' knowledge regarding drawing a ruler independently, while drawing a straight line of a given length using a "broken" ruler 4th grade pupils are statistically better. The results of the research indicate that pupils' achievement is better in doing standard tasks than in non-standard ones, given that the latter require conceptual knowledge. The components of the concept of length measurement using ruler have not been sufficiently developed yet, and these include: zero-point, partitioning a measured object in a series of consecutive measurement units and their iteration. We shed more light on the critical stage in the procedure of length measurement - the transition from non-standard to standard units and the formation of the length measurement scale. For further research, we propose to look at the formation of the concept of length measurement using the ruler through all its components and their inclusion in the mathematics curriculum, as well as examining the correlation of pupils' achievement in the procedure of measuring length with their achievement in measuring area (and volume).

The Development of Visual Inspection for Length Measurement of Injection Product Using Vision System (Vision System을 이용한 사출제품의 길이 측정용 시각검사 System 개발)

  • J.Y. Kim;B.S. Oh;S. You
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.126-134
    • /
    • 1997
  • In this study, We made visual inspection system using Vision Board. It is consist of an illuminator (a fluorescent lamp), image input device (CCD (Charge-Coupled Device) camera), image processing system(Vision Board(FARAMVB-02)), image output device (video monitor, printer), and a measuring instrument(TELMN1000). Length measurement by visual inspection system make use of 100mm guage block(instead of calculating distance between a camera and a object). It measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measure- ment of a injection. A measuring instrument used to ompare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument with visual inspecion system using length factor of 100mm gauge block. We find that maximum error of length is 0.55mm when it compar with the measuring value of two devices(FARAMVB-02, TELMN1000). Program of visual inspection system is made up Borland C++3.1.

  • PDF

Review on the Ancient korea Length, Weight and Volumetric Measures (고대 한국의 도량형 고찰)

  • 김소보;나영아
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.4 no.1
    • /
    • pp.1-18
    • /
    • 1994
  • This study is designed to delve into the measuring systems of different periods so as to help with more exact representations of cultures of different periods. The basis of the measuring system in china stems from the huangjong (Huangzhong : the yellow bell) of the period of Huangdi, the length of the bell being the width of 90 black millet grains. Do (Du : width) ; 1 bun=the width of one black millet grain, 1 Chon=10 Buns, 1 Chuk=10 Chons, 1 Jang=10 Cheoks, 1 In=10 Jangs. Ryang (Lyang : volume) ; 1 Yak=the weight of 1,200 grains in the yellow bell, 1 Hab=2 Yaks, 1Seung=10 habs, 1 Du=10 Seungs, 1 Gok=10 Dus. Hyung (Hung : weight) ; 12 Jus=the weight of 1 Yak, 1Yang=24 Jus are equal 1 Hab in weight, 1 Geun=16 Ryangs, 1 Jo=30 Geuns, 1 Seo=4 Jo. In the era of Eun (In) it was decided that the 9-chon length of the Yellowbell shall be 1 Cheok. The Cheok of Ju was set at 4/5 of the length of the yellow bell. The Cheok of Ju breaks into Yongjocheok, Joryegicheok, Pogeumcheok. Yongjocheok, arising from Rohbancheok of the Ju period, is part of Gokcheok also used as a measuring tool for wooden works. The Han cheok has the same length as the yellow bell. The Sang Cheok is 4/5 of the length of the yellow bell. The Tang Cheok was originally the same as the Sang cheok but became longer and longer to be the Long cheok (31.3cm). The length-measuring system used in the three-nation era of Korea includes the gijeom cheil (35.52cm), Ju cheok (25.45cm), sunje Cheok (23.5cm), the Long Tang Cehok (29.706 cm), making 10 Bun 1 Chon and 10 Chon 1 Cheok. The volume-measuring system(Seung) was 198.81 ㎤ before 681 BC in the shilla Dynasty and was 596.42 ㎤ after that. In the seventh year of Kng Munjong of the Koryo dynasty the standard measuring system with the Long Tang Cheok as its basis was adopted, and the standard volume-measuring tools were used under the name of Migok, Daesodugok, Mijangdu, (29.706 cm), making 10 Bun 1 Chon and 10 Chon 1 Cheok. The volume-measuring system(Seung) was 198.81㎤ before 681 BC in the shilla dynasty and was 596.42 ㎤ after that. In the seventh year of King Munjong of the Koryo dynasty the standard measuring system with the Long Tang Cheok as its basis was adopted, and the standard volume-measuring tools were used under the name of Migok, Daesodugok, Kijangdu, Habseung and gokseok. The 1 Seung volumes of theses toolas were 596,447,927 and 1053㎤, respectively. were called Migok, Daesodugok, Mijangdu, Habseung and Gokseok, being respectively 596,447,927, 1053 ㎤, respectively. In the Chosun Dynasty the length of the Yeongjocheos was 27.6 cm or 31.220 in the Sejong era, 29.8 from Heonjong through Gojong, and 30.3 cm after the 6th year of King Kwangmu, and the volume of Du(Mal) also changed like 4.121 or 5.964, 5.187, 23.08 $\ell$, and the 1-Jeonjung also changed like 2.66 or bout 4, 3.45, 3.75 in line with the changes of the length system.

  • PDF

A Study on the Measuring Rule for Korean Traditional Costume (한복에 사용되는 포백척에 관한 연구)

  • 한은희;유송옥
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.2
    • /
    • pp.135-148
    • /
    • 2001
  • The measuring rule Is to extimate a size of a physical solid and its standard was each part of body since the beginning of the world. Korean traditional measuring rule was "Kyul Boo Sok Pa Bob". It bases on wreth of farm land and means a handful and a bundle. It was the real Korean traditional measuring rule though it was a influence on Chinese rule. And in Koguryo it had an effect on Japanese′s. In Chosun dynasty the King Sejong imprived the measuring rule and regylations in such a way to meet the realistic needs of civil lives. He put in good order by a proportions of the musical scale. It was one of fille correct ways to preserve the measuring rule and based on "Kyul Beo Sok Pa Bob"too. So ill that time the measuring rule for Korean traditional costume′s length was 46.703cm. In king Soonjo it′s length was 49.254cm and in 1926 it changed 50cm by the metric system. In 1990s the standard length has a difference in regions, 30cm, 45cm, 50cm, 54.5cm, 55cm and 60cm. As a result of the actual object investigation by regional measuring rule for Korean traditional costume it can reduce an accidental error when use the standard measuring rule, 50cm.

  • PDF

Development of the system for error evaluation in coordinate measuring machines (3차원 좌표 특정기의 오차 평가 시스템 개발)

  • ;M.Burdekin;G.Peggs
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.116-120
    • /
    • 1991
  • Technique of length measurement error is widely used in the accuracy assessment of CMMS(Coordinate measuring machines) and machine tools, as it is simple and direct measurement within the working volume of a machine. In this paper, a new method is proposed for the evaluation of the length measurement error in relation to the volumetric accuracy. lD, 2D, and 3D measuring lines are considered for recpective length measurement error: 1D, 2D, and 3D length measurement uncertainties are evaluated from volumetric accuracy. The relationship between the volumetric accuracy md length measurement error to is discussed. PC based system for length measurement error evaluation and simulation is developed.

  • PDF

A Study on Analysis of Dimensional Error of Projector for Formulations of Measurement Automation (측정 자동화 구축을 위한 투영기의 치수오차 분석에 관한 연구)

  • Choi, Jisun;Kim, Moon Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.114-118
    • /
    • 2021
  • In this research, the dimensional error of the measured specimen according to the measurement method was analyzed for the length, angle, radius of curvature and diameter using a projector which is used in industry. One-way analysis was performed on each data tested 30 times using a statistical technique. Through the experiment, it was found that an error occurred in each data when measuring the length and radius of curvature according to the measurement method, and the null hypothesis that no error occurred when measuring the angle and length was established. Based on this experimental data, the automatic measurement when measuring the projector causes less measurement error, so automatic measurement is recommended when measuring a small product. Also, an optimal measuring method is suggested for securing reliability on formulations of measurement automation.

Development of a precision length measuring system by using laser (레이저를 이용한 정밀 길이 측정시스템 개발)

  • 김진상;정성종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1415-1418
    • /
    • 1997
  • An accurate length measuring system has been develope by a modified Michelson interferometer. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. Resolutioin of .lambda./40, 16 nm, was achieved from the discrete length measuring system. In order to obtain a resoltuion of 1.mu.m a decimalizing module was designed for the 0.016.mu.m resolution system. The refractive index of the ambient air was calibrated on the decimalizing module through the Edlen's formula. Performance of the system was evaluated on the machining center in short and long length measruements.

  • PDF

A New Method for Measuring Fiber Length and Fiber Coarseness Using Image Analysis Technique (화상분석법을 응용한 섬유장 및 섬유 조도 측정법 개발)

  • 배진한;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.13-21
    • /
    • 2002
  • A new method for measuring fiber length and fiber coarseness was developed using image analysis technique. Measured fibers were transferred to a glass slide on a filter paper placed on a wire of the laboratory paper machine. After staining the fibers on the slide, mean fiber lengths and coarseness were measured by a commercial image analysis software, named KS400. The resultant data obtained from the image analysis displayed a close correlation with those from FS-200 and also showed excellent reproducibility as well as those from FS-200. The length of synthetic fibers over 10 mm long could be readily measured by this new analysis technique. Finally, a substantial improvement in precision for measuring fiber length and coarseness was made with less operator's effort for a given time.

An Analysis on Elementary Students' Measuring Abilities by Using a Microgenetic Method (미시발생학적 방법을 이용한 초등학생의 측정 능력 분석)

  • Yang, Il-Ho;Song, Jin-Lyoung;Lim, Sung-Man;Lim, Jae-Keun
    • Journal of Korean Elementary Science Education
    • /
    • v.27 no.4
    • /
    • pp.341-355
    • /
    • 2008
  • The purpose of this study was to analyze the measuring abilities of elementary school students by using a microgenetic method. The participants were seven elementary students in the fourth grade. To analyze their measuring abilities, students attended three physical quantities measuring tasks such as length, volume, and time task by six times. Results were as follows. First, in the measuring length task, students selected appropriate measuring instruments but they didn't consider measuring amounts. And as their measuring experience increased, they desirably improved management abilities of measuring instruments. In the measuring volume task, they dealed with measuring instruments, but not very well. And these tendency were maintained. In the measuring time task, they were not measure exactly. Second, as their measuring experience increased, their ability to read the scale marks improved. However, they had difficulties in estimating the volume between scale marks. Results indicate that, elementary students need to basic education about measuring instruments, their usage, and scale reading ability for their science experiment courses in schools.

  • PDF