• Title/Summary/Keyword: length measuring

Search Result 1,158, Processing Time 0.023 seconds

The Length of Skirt and the Warmth Retentivity (Skirt의 길이와 보온성)

  • Suh Mi A
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.1 no.2
    • /
    • pp.59-64
    • /
    • 1977
  • The effects of skirt length on warmth retentivity were examined by measuring skin temperature on several parts of the leg warm differency length of skirts in the chamber which controlled at $-7\pm1^{\circ}C$ and $85\%$ R.H. The results were obtained as follows: 1. The high correlative efficients were found between the length of skirt and the warmth retentivity. Little warmth retentivity was found in a mini-skirt. 2. The skin temperature was dropped gradually lower nearing the ankle. 3. The skin temperature was also dropped immediately when the skin was exposed to the cold air, and showed a gradual fall.

  • PDF

Study on the Internal Mixing Flow Characteristics for Recess Length in a Swirl Coaxial Injector (스월 동축형 인젝터에서 리세스 길이에 따른 내부 혼합 유동의 특성 연구)

  • Kim, Sung-Hyuk;Yoon, Jung-Soo;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.13-18
    • /
    • 2010
  • This study aim to investigate the internal mixing flow characteristics by recess length of swirl coaxial injector for gas generator has propellant of Kerosene-LOx. Recess length is a very important element, have influence in spray stability and LOx post damage. The influence of recess length was analyzed by visualizing internal flow and measuring liquid film thickness and manifold pressures. Also, frequency characteristics were analyzed by liquid film thickness measurement with mixing time.

  • PDF

Talbot Interferometry for Measuring the Focal Length of a Lens without Moiré Fringes

  • Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.165-168
    • /
    • 2015
  • A simple method to determine the focal length of a lens using the Talbot image is presented. This method uses only one grating, requiring neither Moir$\acute{e}$ fringe analysis nor the angle between the gratings. The original Fourier transform was used to access the spectrum beyond the limitation set of the usual fast Fourier transform to determine the (de)magnification accurately enough to be used for the focal length. A set of Talbot images simulated numerically with the Fresnel diffraction integral was used to demonstrate the method. For focal lengths between 5550 mm and 5650 mm, the mean difference between the focal lengths determined from the Talbot images and the true values was 3.3 mm with the standard deviation of the difference being 3.8 mm. The true focal lengths can be recovered with an accuracy of 0.06%.

Experimental Study on the Internal Flow Characteristics in a Swirl Coaxial Injector for Gas Generator (가스발생기용 스월 동축형 인젝터에서 내부 유동의 특성에 대한 실험적 연구)

  • Kim, Sung-Hyuk;Yoon, Jung-Soo;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.29-33
    • /
    • 2010
  • This study aim to investigate the internal flow characteristics by recess length of swirl coaxial injector for gas generator has propellant of Kerosene-LOx. Recess length is a very important element, have influence in spray stability and LOx post damage. The influence of recess length was analyzed by visualizing internal flow and measuring liquid film thickness and manifold pressures. Also, each spray characteristic by recess length was investigated in internal or external injector.

  • PDF

Design and Analysis of Displacement/Length Measuring System Using Laser Interferometry (광간섭법을 이용한 변위/길이 측정시스템의 설계 및 해석)

  • Kim, J.S.;Kim, S.C.;Chung, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.151-156
    • /
    • 1997
  • A laser measurement system, a modified Michelson interferometer, which can accurately measure high speed length and displacement of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refra- ctive index of the ambient air was calibrated through the Edlens formula. The system achieved a resolution of /40, 16nm, a maximum allow-able measurement speed of 600nm/sec, and a length measure- ment range of 1500 mm. Performance of the system was evaluated on the machining center in short and long length measurements.

  • PDF

Physical Characteristics of Disabled Women by the Cause of Disability (장애원인에 따른 여성 장애인의 신체 특성)

  • Park, Kwang-Ae
    • Fashion & Textile Research Journal
    • /
    • v.7 no.4
    • /
    • pp.419-425
    • /
    • 2005
  • The purpose of this study is to analyze the physical characteristic by directly measuring the wheelchair using disabled women. The subjects were 103 disabled women of wheelchair used women and between 20 - 55 years of age. The result of this study is as follow. There was a remarkable difference in the physical characteristic of wheelchair using disabled women due to their cause of disability. The cause of disability was classified into the 4 groups; poliomyelitis, spiral cord injury, muscular dystrophy, cerebral palsy. Poliomyelitis disability generally had a large horizontal area due to their strong upper body. People with spiral cord injury disability was shown to have the largest height, cervical height, waist back length, crotch length, knee length, The group of muscular dystrophy disabled people have the shortest length of body and also lean. The cebral palsy group of disabled people has an average length and height size body. A comparison of anthropometric measurements of wheelchair using disabled women with National Anthropometric Survey Korea(1997) was significant difference. People with poliomyelitis disability was shown to have a larger waist back length, neck point to breast point compared to normal women, but stature, crotch length was shorter compared to normal women. People with spiral cord injury disability had a similar in the vertical area. The group of muscular dystrophy and cebral palsy disabled people was short and smaller in general compared to a normal woman.

Analytical model for transfer length prediction of 13 mm prestressing strand

  • Marti-Vargas, J.R.;Arbelaez, C.A.;Serna-Ros, P.;Navarro-Gregori, J.;Pallares-Rubio, L.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.2
    • /
    • pp.211-229
    • /
    • 2007
  • An experimental investigation to determine the transfer length of a seven-wire prestressing strand in different concretes is presented in this paper. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the prestressing strand on a series of specimens with different embedment lengths has been used. An analytical bond model to calculate the transfer length from an inelastic bond stress distribution along the transfer length has been obtained. A relationship between the plastic bond stress for transfer length and the concrete compressive strength at the time of prestress transfer has been found. An equation to predict the average and both the lower bound and the upper bound values of transfer length is proposed. The experimental results have not only been compared with the theoretical prediction from proposed equations in the literature, but also with experimental results obtained by several researchers.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

A Study on the Development of Low Frequency Electronic Ignition Trans for Large Combustors (대형연소기에 적용되는 저주파 전자식 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • In this paper, the ignition trans used in boilers was studied. Regardless of the change in the ignition rod length and the ignition rod gap, the output frequency was measured between 59.5 and 61.3 Hz, and it was found that the low frequency circuit operated normally. When the ignition rod gap changed by 2 to 10 mm, the ignition rod length was measured from 2.8A to 3.45A at 30cm. The ignition rod length was measured from 9.37 A to 14.5 A at 500 cm and from 13.2 A to 32.6 A at 1000 cm. As the ignition rod length and the ignition rod gap increased, the current increased. As a result of measuring the secondary coil output voltage. The ignition rod length was measured from AC 0.84 kV to AC 1.75 kV at 30 cm, AC 1.17 kV to AC 1.944 at 500 cm, and AC 1.4 kV to AC 7.18 kV at 1000 cm. As the ignition rod length and the ignition rod gap increased, the output voltage of the secondary coil also increased. As a result of measuring the output voltage of the ignition trans, the ignition rod length was measured from DC 1.11 kV to DC 1.57 kV at 30cm, DC 2.49 kV to DC 3.72 kV at 500cm, and DC 3.78 kV to DC 9.42 kV at 1000cm, and the power voltage increased as the ignition rod length and interval increased.

IN VIVO EVALUATION OF ACCURACY OF TWO ELECTRONIC APEX LOCATORS (전자근관장 측정기의 정확도에 관한 연구)

  • Kim, Hee-Jung;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.289-299
    • /
    • 1996
  • It is necessary to measure the length of a root canal in order to attain a satisfactory prognosis after root canal therapy. There are several methods for determining root canal length, such as tactile sensation by the dental practitioner, the utilization of x-ray film, and electronic root canal measurement. Among these, the electrical measurement methods, in which the impedence between the oral mucous membrane and periodontal membrane is determined, have advantages of simplicity and accuracy. During root canal treatment, the root canal contains a solution of high electrical conductivity such as pus, blood, sodium hypochlorite and so on. Recently a new electronic root canal measurement device of frequency-dependent type has been developed, which is capable of measuring the length of root canal under moist conditions. Endex and Root ZX, which are frequency-dependent type, were evaluated for accuracy of measuring root canal length in vivo by stereomicroscope. The result were as follows ; 1. 82.5% of Endex and 87.5% of Root ZX measured in the range of ${\pm}0.5$ mm from the apical foramen and both showed 57.5 % in the range of 0.1 mm to 0.5 mm. 2. Endex showed significantly higher accuracy in vital teeth than nonvital teeth(p<0.05). But in case of Root ZX, there was no significant difference between vital and nonvital teeth. 3. As a result of this study, there was no significant difference in accuracy between Endex and Root ZX, and both devices showed file passes the apical foramen in more than half of the cases, and it is thought that this must be considered clinically.

  • PDF