• Title/Summary/Keyword: length measuring

Search Result 1,158, Processing Time 0.034 seconds

Experiment Study on the Spray Characteristics according to the Design Factors and SMD Measuring Direction of Y-jet Nozzle (Y-jet 노즐의 설계인자와 SMD 측정방향에 따른 분무특성의 실험 연구)

  • Lee, Sang Ji;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.205-211
    • /
    • 2018
  • Y-jet nozzle has various advantages over other twin-fluid nozzles and are used in industrial boilers. However, it costs large energy consumption because of assisted air and its design is complex. The Y-jet nozzle is consisted of a liquid and gas port and a mixing chamber. The diameter of the port and the length of the mixing chamber greatly affect spray and atomization characteristics, therefore, they are the most important factors in nozzle design. In this study, The experimental setup is consisted of a laboratory scale spray system. The characteristics of the Y-jet nozzle according to the design parameters were observed. As a result, it was found that the length of the mixing chamber did not have effect on the flow rate and the choking condition. The droplet size was measured using a Malvern type measuring device. In addition, measurements were conducted in the front and the right directions of the nozzles. Based on the results, the SMD View Ratio is defined. It is the asymmetrical design characteristics of the Y-jet nozzle.

HOT STRIP WIDTH CONTROL METHOD BY USING LOOPER TENSION MEASURING SYSTEM IN FINISHING MILL (열간 사상압연 투퍼장력 측정에의한 열연판폭제어)

  • 홍완기;김필호;문영훈;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.423-428
    • /
    • 1999
  • A high precision hot strip width control method has been developed in this study by applying interstand looper tension measuring system at finishing mill stands. As with deviation of hot rolled steel strip is closely related to abnormal increase in the interstand strip tension, on-line measuring device of looped tension and data analyzing system was developed in this study. To determine dominant factors that will cause local width shortage, the logged data sets of bar width, bar thickness, looper tension, and strip thickness along the strip length were correlated with the data set of strip width change. With the result of the correlation analysis, existing sequence control logic and parameters for looper actuator were modified for strip width quality and the gains of the looper control were refined for the stable operation during the full passage of rolled strip. The on-line tension measurement and tension feedback control for looper system improved strip travelling stability and reduced strip width deviation in the srip top end region.

  • PDF

Measurement of Stride Length Using Optical Method (광학적 분석방법을 이용한 보폭측정)

  • Jung, Gu-In;Jun, Jae-Hoon;Lee, Kang-Hwi;Song, Min-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1116-1122
    • /
    • 2008
  • Since conventional methods for measuring stride length(distance) are many weaknesses, optical methods have been developed to measure stride length(distance) of human pedestrians. IR(Infrared) elements and Power LED(Light Emitting Diode) with two types of lens were used to correlate detected light intensity with stride length(distance). The suggested methods in this study are simple, convenient, and cost effective. The results can be used to analyze walking patterns of normal and disabled men, and to monitor the recovering processes of the disabled patients.

A Study on the Visual Evaluation about Silhouete Image -Based on X-line- (실루엣 이미지의 시각적 평가에 관한 연구 -X-line의 변화를 중심으로-)

  • 이은령;이경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.4
    • /
    • pp.631-646
    • /
    • 1996
  • The purpose of this study was to investigate the difference of visual evaluation about silhouette image. The specific objective were; 1) to construct of silhouette image evaluation instrument using semantic differential scale for the purpose of measuring the width and length; 2) to identify the factor structure of the silhouette; 3) to test the difference of visual perception to the silhouette as the variation of width; 4) to test the difference of visual perception to the silhouette as the variation of length; 5) to test interaction effect between width and length. The major finding were; For the visual evaluation of silhouette as shoulder width variatiorl, there were significant difference in hardness and softness factor. For the hard and soft image, we should express by variation of the shoulder width. For the visual evaluation of silhouette as skirt width variation, there were significant difference in attention factor. For the attensive image, we should express by variation of the skirt width. For the visual evaluation of silhouette as skirt length variation, there were significant difference in activity factor. For the active image, we should express by variation of the skirt length.

  • PDF

Odd-Even Effects of the Anchoring Strength for Nematic Liquid Crystal on Rubbed Polyimide LB Surfaces (러빙처리된 폴리이미드막 LB막에 있어서 네마틱액정의 결합강도의 홀수짝수 효과)

  • Seo, Dae-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1453-1455
    • /
    • 1996
  • The odd-even effect of the alkyl chain length of rubbed polyimide Langmuir-Blodgett (LB) surfaces on the extrapolation length of 5CB has been successfully evaluated for the first time by measuring polar anchoring strength. The extrapolation length of 5CB for rubbed PI-LB surfaces with even-numbers is small compared with odd-numbers for alkyl chain lengths of greater than 7 carbons. The extrapolation length of 5CB on rubbed PI-LB surfaces with odd-numbers increases gradually as the temperature increases but tends to diverge near the clearing temperature (Tc=$35.3^{\circ}C$). The extrapolation length diverges because of rapidly decreasing surface order near $T_c$. We suggest that the polar anchoring strength on rubbed PI-LB surfaces with even-number is strong because of relatively high surface ordering caused by more crystalline surfaces. Finally, we conclude that the odd-even effects of the polar anchoring strength in NLCs are strongly related to the character of the polymer and observed clearly for long alkyl chain lengths.

  • PDF

The variation of optical pass length between incident and reflective beam in multilayer thin film (다층박막에서의 입사광과 반사광의 광로정변화)

  • 김문환;최영규
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.515-520
    • /
    • 2002
  • The variation of the optical pass length between incident and reflective beam in a multilayer thin film reflection mirror is investigated. This variation is caused mainly by environmental parameters around the optical system, such as the air pressure, temperature, humidity and $CO_2$concentration. In this paper, a new method for measuring optical pass length variation is proposed. This optical pass length is measured against the above parameters by experiment. From the experimental results, it is clarified that the optical pass length is mostly effected by humidity changes.

The development of jacket patterns for baby-boomer generation women according to silhouette (베이비붐 세대 여성의 실루엣에 따른 재킷 패턴 개발)

  • Choi, Chang Sook;Kim, Ji Hyeon;Kim, Hyo Sook
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.5
    • /
    • pp.778-792
    • /
    • 2015
  • The purpose of this study is to identify women (aged from 49~59), who have recently emerged as consumers, and their clothing preferences, and it suggests how to make jackets provide better fit and wearability. The results of the study are as follows. In drafting a pattern for size 66 tailored collar jacket with an X-silhouette, it was made with front waist length measuring B/4+1.5 cm, a back length of B/4+1.3 cm, an armhole depth of B/4, a hip ease of H/4+1.2 cm and a sleeve opening of 34.5 cm, to allow for easy movement. In drafting a size 66 high neck collar jacket, it was made with a front and back waist length measuring B/4+1.5 cm, an armhole depth of B/4, a hip ease of H/4+1.2 cm and a sleeve opening of 35 cm. In drafting a size 66 sports collar jacket with an A-silhouette, it was made with front and back waist lengths measuring B/4+1.5 cm, an armhole depth of B/4, and a side dart of 1.3 cm, to provide raglan sleeves. The last experimental jacket pattern improved the appearance and moving fitness evaluation especially for shoulder and arm movement. Based on analysis, jackets were made and subjected to an appearance evaluation using multi-modules to test the level of wearing satisfaction for each fabric and silhouette. the results of the multi-module wearing tests indicate that the preferred silhouettes caused less stressful situations in terms of both psychological and physiological signals.

The effect of tool length on distance compression to the pointed object (도구의 길이가 가리키는 대상까지의 거리압축에 미치는 영향)

  • Hong, Seongkyun;Kim, ShinWoo;Li, Hyung-Chul O.
    • Korean Journal of Cognitive Science
    • /
    • v.29 no.1
    • /
    • pp.17-38
    • /
    • 2018
  • The purpose of present study was to examine whether the perceived distance is compressed to different extent according to the length of the tool in the object that is not reachable even when using the tool, and whether the perceived distance is compressed according to the tool length only in the object being pointed. In Experiment 1, we found by measuring the egocentric distance that the length of the tool causes the distance to the target to be closer to that of the object placed at a far distance. In Experiment 2, we found by measuring the egocentric distance that when the operated object and the non-operated object coexisted in the visual field, the length of the tool does not affect the distance perception to the non-pointed object. In Experiment 3, we found that the tool length affects only the distance perception of the operated object by measuring the exocentric distance which is the distance between the operated object and the target in the same environment as Experiment 2. The results of present experiment suggest that the compression of the perceived distance occurs at a distance that can not be reached by using the tool, and that the compression of the perceived distance is limited to the pointed object.

Tests on Transfer Bond Performance of Epoxy Coated Prestressing Strands (에폭시 코팅 처리된 PS강선의 정착부착성능 실험)

  • 유승룡
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.1
    • /
    • pp.89-100
    • /
    • 1994
  • The current test procedure for transfer length, which determine transfer length by measuring concrete strain, has an actual bond stress state in the prestressed pretensioned member : however, it is difficult to determine the bond properties of maximum bond stress and bond stiffness with this method. It is also difficult for design engineer to understand and select a correct safety criterion from the widely distributed results of such a ransfer test alone. An alternative testing procedure is provided here to determine the bond properties without measuring the concrete strain. In this test the bond stress is measured directly by creating a similar boundary condition within the transfer length in a real beam during the transfer of prestressing force. The prestressing force was released step by step by step from the unloading side. The release of force induces a swelling of the strand at the unloading side of concrete block, bonding force in the block, and a bond slip of the strand toward the other side of the block. Two center-hole load cells are used to record the end loads until the point of general bond slip(maximum bond stress). It is suggested that this test procedure be performed with the ordinary transfer test when determining the transfer length in a prestressed, pretensioned concrete beam.

Development of Multi-Axis Control Program for Long Range AFM Using an FPGA Module (FPGA 모듈을 이용한 Long Range AFM용 다축 제어 프로그램 개발)

  • Lee J.Y.;Eom T.B.;Kim J.W.;Kang C.S.;Kim J.A.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.289-290
    • /
    • 2006
  • In general, atomic force microscope (AFM) used for metrological purpose has measuring range less than a few hundred micrometers. We design and fabricate an AFM with long measuring range of $200mm{\times}200mm$ in X and Y axes. The whole stage system is composed of surface plate, global stage, microstage. By combining global stage and microstage, the fine and long movement can be provided. We measure the position of the stage and angular motions of the stage by laser interferometer. A piezoresistive type cantilever is used for compact and long term stability and a flexure structure with PZT and capacitive sensor is used for Z axis feedback control. Since the system is composed of various actuators and sensors, a real time control program is required for the implementation of AFM. Therefore, in this work, we designed a multi-axis control program using a FPGA module, which has various functions such as interferometer signal converting, PID control and data acquisition with triggering. The control program achieves a loop rate more than 500 kHz and will be applied for the measurement of grating pitch and step height.

  • PDF