• 제목/요약/키워드: length measurement

검색결과 2,201건 처리시간 0.031초

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

치과용 Co-Cr sinter metal의 소결 후 변형비교 (Observation of Shape after sinter of Dental Co-Cr sinter metal)

  • 송준부;김갑진
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.127-133
    • /
    • 2016
  • Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.

Grafting-onto법에 의한 poly(MMA-co-PEGMA) 전해질의 합성과 이온전도도에 대한 조성의 영향 (Synthesis of Poly(MMA-co-PEGMA) Electrolytes by Grafting-onto Method and Effect of Composition on Ionic Conductivities)

  • 이주형;류상욱
    • 전기화학회지
    • /
    • 제16권4호
    • /
    • pp.198-203
    • /
    • 2013
  • 본 실험에서는 MMA와 tBMA의 공중합체를 합성하고, tert-butyl 그룹의 가수분해를 선택적으로 유도하여 poly(MMA-co-MA)를 제조하였다. 또한 말단에 에폭시기를 함유한 다양한 분자량의 PEO와 MA와의 grafting-onto 커플링 반응을 통해 같은 주사슬을 가지지만 부사슬의 길이가 다른 poly(MMA-co-PEGMA)를 합성하여 조성이 이온전도도에 미치는 영향을 평가하였다. AC-impedance로 측정한 상온 이온전도도는 MMA의 몰분율이 82%에서 $5.11{\times}10^{-8}Scm^{-1}$의 값이 얻어진 반면, 48%에서는 $1.88{\times}10^{-6}Scm^{-1}$로서 많은 PEGMA에서 높게 관찰되었다. 또한 에폭시기를 함유한 PEO의 분자량에 따라 이온전도도의 차이가 발생하는데, grafting-onto 법의 입체적 장애가 원인으로 고려되었다. 한편, 합성된 poly(MMA-co-PEGMA) 고분자 전해질은 상온에서 6V까지 우수한 전기화학적 안정성을 보여주었다.

765 kV용 400 kN 현수애자 개발 (Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines)

  • 최인혁;최장현;이동일;최연규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

부 모드 억제율이 향상된 소형 이중 링 공진 반사기 기반 하이브리드 집적 파장 가변 레이저 (Hybrid-Integrated Tunable Laser Based on Small Double-Ring Resonator with Improved Side Mode Suppression Ratio)

  • 권오상;정영철
    • 한국광학회지
    • /
    • 제22권2호
    • /
    • pp.102-107
    • /
    • 2011
  • 본 논문에서는 폴리머 도파로를 이용하여 소형 이중 링 공진 반사기를 설계하고 제작하여 그 측정 결과를 분석하였다. 소형 이중 링 공진 반사기는 반경이 서로 다른 두 개의 링 공진기 구조에 의한 버니어 효과로 인해 넓은 범위의 파장가변 특성을 확인 할 수 있었다. 소형 이중 링 반사기의 삽입 손실을 줄이기 위해 도파로의 길이를 기존에 보고된 소자에 비하여 크게 줄임으로써 부 모드 억제율이 크게 향상됨을 확인 하였다. 측정결과 소형 이중 링 공진 반사기 기반 하이브리드 집적 레이저는 45 dB의 부모드 억제율을 유지하면서 단일 모드로 발진함을 확인하였다. 또한 소형 이중 링 공진 반사기 상부에 형성된 전극에 최대 30 mA의 튜닝전류를 인가하여 약 40 nm 까지의 파장가변을 확인하였다.

비만 여성의 체형 특성 분석을 위한 비만 판정 지수의 비교 (A Comparative Study on Obesity Judgment Indices for Body Characteristics Analysis in Korean Obese Women)

  • 이경화
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.1141-1154
    • /
    • 2009
  • As a preliminary research of body characteristics analysis of Korean obese woman, this study aims to select optimal obesity judgment tools for reliable sampling of obese subjects from 2,425 female measurement data out of 2004 Size Korea project's raw data. From previous researches related to obesity, 7 obesity judgment tools were chosen. 2007 obesity rate(26.3%) of Korean female adults was refered in selecting optimal obesity judgment criteria in the study. The results are as follows. Firstly, it was verified that BMI was the most suitable in judging and sampling the obese subjects by the percentile analysis. R$\ddot{o}$hrer index was also reliable in grouping the obese subjects from a population. Secondly, it was concluded that the obesity ratios of relative weight 120 and higher group, R$\ddot{o}$hrer index 1.6 and higher group and waist girth 80cm and higher group were the most similar to obesity rate of Korean female adults by 2007 National Health & Nutrition Survey. Thirdly, 30 direct measurements, age, 2 drop values and 6 ratios of 7 groups by the obesity judgment tools showed the significance each other at p<0.001 level. On the other hand, "bust point to bust point" and "waist to hip length" measurements didn't show the significant differences among 7 groups. Conclusively, 4 to 5 satisfactions out of 7 obesity judgment criteria were adequate and sufficient in sampling the obese subjects. If it is needed the strict criteria for judging the obesity, 5 satisfactions and higher group will be the best choice as the obese subjects. However 4 satisfactions and higher group generally, will be adequate for sampling of the obese subjects.

  • PDF

Design of LED Bicycle Headlamp with a Horizontally Wide Viewing Angle

  • Park, Hyun Jung;Lee, Dong Kyu;Lee, Jae Min;Park, Kwang-Woo;Joo, Jae Young;Kwak, Joon Seop
    • Current Optics and Photonics
    • /
    • 제1권4호
    • /
    • pp.351-357
    • /
    • 2017
  • This paper proposes a LED bicycle headlamp with a wide viewing angle to help bicyclists see the front effectively and because of its high visibility to reduce the risks of accidents around intersections or blind spots. The wide viewing angle was determined to be $28^{\circ}$ because it can illuminate a 5 m wide area 10 m away. Therefore, the road conditions of the intersection can be observed with the bicycle handlebar tilted slightly to the left or right. The headlamp has a compact reflector with a width of 30 mm, height of 27 mm, and length of 17 mm. Owing to its size, a change in the position of a light source leads to severe changes in light distribution. Therefore, the tolerance of the source position was analyzed by a simulation. The tolerance was ${\pm}0.5mm$ at the X, Y and Z axes within a less centered aiming range of ${\pm}1^{\circ}$. Finally, the prototype of the bicycle headlamp was made and the light distribution was measured by an automotive headlamp light measurement system. The experimental results indicate that the headlamp illuminates a 5 m wide area with an edge light of 3.2 lx as well as meeting the K-mark regulation.

궤환신호로 보상되는 Michelson 레이저 간섭계를 이용한 $Fe_49Co_49V_2$ 합금의 자기변형 측정 (Magnetostriction Measurement of an $Fe_49Co_49V_2$ Alloy using the Michelson Laser Interferometer Compensated by Feedback Signal)

  • 안승준;김철기;김호섭;김호철;남궁정
    • 한국자기학회지
    • /
    • 제10권5호
    • /
    • pp.246-249
    • /
    • 2000
  • Fe$_{49}$ Co$_{49}$ V$_2$합금을 50$0^{\circ}C$, 75$0^{\circ}C$, 80$0^{\circ}C$ 및 90$0^{\circ}C$의 furnace에서 열처리한 후, 공냉조건으로 냉각하여 시료를 제작하였다. Michelson 레이저 간섭계를 이용하여 시료의 자기변형을 측정하였다 시료의 자기변형은 간섭계의 한쪽 팔에 piezoelectric transducer(PZT)를 부착하여 간섭계의 두 팔 사이의 상대적 광경로를 일정하게 유지하였으며 궤환회로의 전압을 광경로의 변화(자기변형)로 환산하였다. 시료를 90$0^{\circ}C$의 furnace에서 열처리한 후, H = 60 Oe에서 Fe$_{49}$ Co$_{49}$ V$_2$합금의 자기변형을 측정한 결과열처리 전 2$\times$$10^{-6}$ 에서 33.68$\times$$10^{-6}$ 가지 증가하였다. 이것은 시료의 미세구조가 변화되어 자기특성이 개선된 것으로 생각된다.

  • PDF

브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작 (Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke)

  • 박포규;김영균;신석우;최형호;김태익;정동근
    • 한국자기학회지
    • /
    • 제13권6호
    • /
    • pp.251-256
    • /
    • 2003
  • 컴퓨터, TV, 의료용기기 등의 모니터로 사용되는 브라운관의 자기장 영향에 따른 특성을 분석하기 위한 자기장 발생 및 측정장치를 개발하였다. 한 변의 길이가 2 m인 정육각형 형태의 3-축 자기장 발생장치, 컴퓨터, 전원공급기 및 자기장 측정기 등을 이용하여 전세계 각 나라별 지구자기장(Earth Magnetic Field, EMF)을 발생시킬 수 있는 대형 3-축 코일 시스템을 설계하고 제작하였다. 각 코일의 코일상수는 X축(E-W)는 30.31 $\mu$T/A, Y축(Ver)는 29.73 $\mu$T/A 및 Z축(N-S)는 30.51 $\mu$T/A이고, 자기장 분해능은 0.01 $\mu$T이었다. 자기장 균일도는 사용되는 편향요크(Deflection York, DY)의 크기를 고려하여 중심에서 12 cm 이내의 공간에서 측정하였고, 균일도는 1 % 내외 이었다.