DOI QR코드

DOI QR Code

Observation of Shape after sinter of Dental Co-Cr sinter metal

치과용 Co-Cr sinter metal의 소결 후 변형비교

  • 송준부 (부산가톨릭대학교 치기공학과) ;
  • 김갑진 (부산가톨릭대학교 치기공학과)
  • Received : 2016.06.03
  • Accepted : 2016.09.09
  • Published : 2016.09.30

Abstract

Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.

Keywords

References

  1. Jin MN. Evaluation of the fit of cobalt-chromium metal-ceramic crown coping produced by CAD/CAM before and after firing, Dept. of Dentistry, The Graduate School, Yonsei University, 2012
  2. Kim CY, Chung IS. Evaluation of Mechanical Characteristic and Biological Stability of Dental Alloys by the Manufacture Method, Journal of the Korea Contents Association 11(3), 293-301. 2011. https://doi.org/10.5392/JKCA.2011.11.3.293
  3. Kim DK, Lim JH, Lim HS. On The marginal fidelity of all-ceramic core using CAD/CAM system, J Korean Acad Prosthodont, 41, 20-34, 2003.
  4. Kim JH, Kim WS, Kim KB. Evaluation of Marginal Gap of Fixed Dental Prostheses Fabricated by Soft Metal Material Using Dental CAD/CAM, journal of dental hygiene science, 14(3), 349-355. 2014. https://doi.org/10.17135/jdhs.2014.14.3.349
  5. Kim KJ, Chung IS, Choi SM. The Surface Property and Shear Bonding Strength according to Composition of Ni-Cr alloy for Porcelain Fused to Metal Crown, Journal of Korean academy of dental technology, 35(2), 133-120. 2013.
  6. Lee BJ. Shear bond strengths of ceramic to a soft milling cobalt-chromium alloy and a base metal casting alloy, Department of dentistry Graduate School, Kyungpook National University, 2014.
  7. Lee SE, Lee SH, Jeon YC, Jeong CM, Yun MJ, Huh JB. The implant overdenture on the edentulous mandible using CAD/CAM system: A case report, Journal of Korean academy of prosthodontics, 53(1), 66. 2015. https://doi.org/10.4047/jkap.2015.53.1.66
  8. May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit, The Procera Allceram crown. J Prosthet Dent, 80, 394-404. 1998. https://doi.org/10.1016/S0022-3913(98)70002-2
  9. Noh HR, Sun GJ, Joo KJ. Evaluation on the Marginal Fitness of Zirconia Core fabricated with CAD/CAM System. The Journal of the Korea Contents Association, 13(11), 800-806. 2013. https://doi.org/10.5392/JKCA.2013.13.11.800
  10. Song JB. Comparison of deformation with sinter of Dental CAD/CAM Co-Cr sinter metal. Dept. of Dental Laboratory Science, Graduate School, Catholic University of Pusan, 2016.
  11. Tinschert J, Natt G, Mautsch W SH, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent, 26, 367-74. 2001.
  12. Wang CJ, Nathanson DN. Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation. J Prosthet Dent, 67, 786-90. 1992. https://doi.org/10.1016/0022-3913(92)90583-V