• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.029 seconds

A Study on stylistic measurement of Chogori with Museum specimens (유물실측을 통한 여자저고리의 치수연구)

  • 유송옥
    • Journal of the Korean Society of Costume
    • /
    • v.32
    • /
    • pp.21-30
    • /
    • 1997
  • Chogori the basic upper garment of korea costume occupies an important role in tra-ditional dressing and continues to be in use to the present days. Of course there has been changes in the length and line of Chogori with the flow of time based on the Ancient Yoo. This is a study of the 14 parts of Chgori based on statistical analysis by computing the practical measuements. Here the statistical analysis is a objective and quantitative of the stylistic changes in Chogori with time. In this study from the data the Mean and Standard deviation has been evaluated and periodic change is shown by graph to test the periodic change T-test Regressional analysis Index analysis has been used. The results are as follows: 1. The length of clothing has changed with time except the sleeve length. Here the length of clothing means all the other measurements ex-cept the sleeve Thus while the measurements of sleeve length has been uniquely unchanged the other measurements have influenced each other. 2. Generally the form of Chogori had the tendency towards smallness in the 19th cen-tury. But it tended to get larger in the 20th century. 3. Compared to other periods the mode of 19th and 20th century Chogori was widely ac-cepted as the Standard deviation of that period was very narrow. 4. The results seen from the regressional analysis of the Cho-sun period woman's Chogori satisfy the t-value and R-squared and thus support the regression formula presump-tion. 5. From the index analysis it is revealed that with decrease in the armhole measurement sleeve measurement and neckband; relatively same decrease in the wrist measurement; and very marked decrease in the sideline measurement.

  • PDF

Comparison of the Results between Cadaveric and Radiological Measurements of Calcaneus (종골의 사체 실측 결과와 방사선학적 측정 결과의 비교)

  • Kim, Jung-Han;Gwak, Heui-Chul;Lee, Chang-Rack;Jeong, Dong-Woo;Roh, Sang-Myung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.3
    • /
    • pp.102-106
    • /
    • 2015
  • Purpose: We wanted to compare the results between cadaveric and radiological measurements of calcaneus. Materials and Methods: Sixty three calcaneus of 33 cadavers donated between December 2012 and December 2014 were actually measured. Computed tomography (CT) images of 244 calcaneus in 122 patients of the same age group with cadavers were radiologically measured. Maximum length, maximum width, maximum height, $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were measured. Results: In cadaveric measurement, the mean maximal height, length, and width were $41.8{\pm}3.3mm$, $73.3{\pm}3.4mm$, and $40.7{\pm}2.2mm$, respectively. In radiological measurement, the mean maximal height, length, and width were $38.5{\pm}4.3mm$, $74.0{\pm}5.7mm$, and $44.7{\pm}1.4mm$, respectively. In cadaveric measurement, the mean $B\ddot{o}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.1^{\circ}{\pm}6.2^{\circ}$, $110.8^{\circ}{\pm}8.1^{\circ}$, $55.8^{\circ}{\pm}6.8^{\circ}$, and $59.7^{\circ}{\pm}4.6^{\circ}$, respectively. In radiological measurement the mean $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.6^{\circ}{\pm}3.8^{\circ}$, $113.7^{\circ}{\pm}5.7^{\circ}$, $62.2^{\circ}{\pm}3.9^{\circ}$, and $61.6^{\circ}{\pm}6.3^{\circ}$, respectively. The mean maximal height was significantly higher in the cadaveric measurement group (p<0.001) and the mean maximal length and width were significantly higher in the radiologic measurement group (p<0.001, p<0.001). The mean Gissane angle, Fowler-Philip angle, and $B{\ddot{o}}hler$ angle were significantly higher in the CT group (p=0.001, p<0.001, p=0.016, respectively). There was no significant difference in the mean tala-articular angle (p=0.352). Conclusion: Significant differences in length parameters were observed between the cadaveric measurement group and the radiologic measurement group. However, no significant differences in angular measurements were observed between the two groups. The authors carefully conclude that radiological measurement values may be different from actual values in the calcaneus.

Certification of magnification standards for the establishment of meter-traceability in microscopy (현미경의 길이표준 소급성 확립을 위한 배율 교정 시편 인증)

  • Kim J.A.;Kim J.W.;Park B.C.;Eom T.B.;Kang C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.645-648
    • /
    • 2005
  • Microscopy has enabled the development of many advanced technologies, and higher level microscopic techniques are required according to the increase of research in nano-technology and bio-technology fields. Therefore, in many applications, we need to measure the dimension of micro-scale parts accurately, not just to observe their shapes. To establish the meter-traceability in microscopy, gratings have been widely used as a magnification standard. KRISS provides the certification service of magnification standards using an optical diffractometer and a metrological AFM (MAFM). They are based on different measurement principles, and so can give complementary information for each other. In this paper, we describe the configuration of each system and measurement procedures to certificate grating pitch values of magnification standards. Several measurement results are presented, and the discussion about them are also given. Using the optical diffractometer, we can calibrate a grating specimen with uncertainty of less than 50 pm. The MAFM can measure a grating specimen of down to 100 nm pitch value, and the calibrated values usually have uncertainty less than 500 pm.

  • PDF

A Study on the Limit of Dynamic Rrange Improvement of Complementary Con-elation OTDR Caused by the Increased Measurement Cycle at Long Code Length (Complementary Correlation OTDR에서의 긴 코드 길이에 따른 측정시간 증가에 의한 Dynamic Range 증가 제한에 대한 연구)

  • 김동선;박재홍
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.11
    • /
    • pp.19-28
    • /
    • 2003
  • The limitation on the dynamic range improvement of the complementary correlation optical time domain reflectometer(CCOTDR) is presented. In CCOTDR, the improvement of dynamic range is function of both the averaging number of measurement cycles and the length of codes. The trade off between the averaging number and the code length restricts the improvement of the dynamic range and a very long code is not effective to improve the dynamic range. In this paper, the improvement limitation on dynamic range caused by the trade off between the averaging number and the code length is presented. For derivation of the trade off, the number of one measurement cycles employing a conventional single pulse method and employing a complementary code method are presented and compared. And the effective maximum code length is presented in addition.

A Study on the Somatotype Characteristics of Adolescent Girls between the Ages of 13 and 18 (13~18세 청소년기 여학생의 체형 특성에 관한 연구)

  • Kim, Sangmi;Kim, Sora
    • Human Ecology Research
    • /
    • v.57 no.4
    • /
    • pp.513-522
    • /
    • 2019
  • This study analyzes the characteristics of somatotype changes of girls from the ages of 13 to 18 that provide basic data on clothing construction for middle and high school girls. We use data obtained from body measurements of 1,590 adolescent girls 13 to 18 years of age provided in the 6th national anthropometric survey report. The differences among the age groups for 56 direct measurements were analyzed by ANOVA, and the structures of the differences by SNK (Students-Newman-Keuls test) were analyzed. The two major growth ages were 'ages 13-14' and 'ages 15-16'. The first major growth ages focused on all measurement items of height, length, circumference, breadth, depth and other items. The second one focused on measurement items of height and length of torso, circumference, and breadth of lower body. The major growth pattern of the age groups was 'ages 13<14&15<16&17&18' which appeared focused on the height and length items of upper body and torso, the width items of lower body and the circumference items of upper body and lower body. The measurement items of front length like waist front length, N.P. to B.P to waistline, N.P. to B.P., and B.P. to B.P. showed the growth pattern for 'ages 13<14<15<16<17&18'.

New Standards for Measurement in Meridians & Acupoints by Taking the Size of Normal Male Legs (정상 성인 남자(男子) 하지부위(下肢部位)의 수혈(?穴) 정위(定位)를 위한 도량형(度量衡) 산출)

  • Yu, Shin-Jong;Kwon, Oh-Sang;Ahn, Seong-Hoon;Kim, Young-Jin;Kim, Kyung-Sik;Sohn, In-Chul;Kim, Jae-Hyo
    • Journal of Pharmacopuncture
    • /
    • v.13 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Objective : Standard of measurement in Korean Medicine has been changed in dynasty and location. Thus, cun (寸) and chi (尺) as unit of measurement for meridians and acupoints could be recognized as the length of equally divided portions of a certain long bone or the distance between two anatomical landmarks and as an symbolical meaning to date. The goal of this study is to propose a new standard measurement in the metric system for the relative measurement of cun and chi as unit of measurement for meridians and acupoints in normal male legs. Methods : This study was conducted by gauging each parts of normal male legs in the metric system and comparing to the relative measurement of cun and chi as follows; to calculate 1 cun, the length of each parts was divided into the unit of cun referred to Measurement of the Bone in Neijing Lingshu (靈樞 骨度篇); it was compared the unit of cun referred to Measurement of the Bone in Neijing Lingshu with cun which was calculated by dividing subject's height into 75 cun, respectively. Result : There has no significant difference in length of 1 cun among each leg's areas based on a standard of subject's height. The unit of cun by the metric length in the legs was similar to the unit of cun referred to Measurement of the Bone in Neijing Lingshu based on each subject's height. Conclusion : It is suggested that an unit of cun as the measurement for meridians and acupoints in the male legs should be considered to the ranges from 2.4cm to 2.6cm.

A Study on a Pattern Design for Pleated Skirts Based on the Amount of Waist Darts by Somatotype (체형별 허리 다트량을 활용한 플리츠 스커트 원형 설계에 관한 연구)

  • Lee, Jung-Hwa;Maruta, Naomi;Hirokawa, Taeko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.8
    • /
    • pp.933-945
    • /
    • 2011
  • This research proposes a pattern design method for 24 pleated skirts in order to develop an automatic draft program for pleated skirts that will enhance fit and enable mass production. The research method and results are outlined as follow. 1. Three-dimensional body measurements were conducted on 30 randomly selected women in their 20s. By using 34 body measurement items and 6 types of calculations among the items, the items required in the designing of an original pleated skirt were extracted. They were then interpreted through correlation analysis, variance analysis, a t-test, linear regression analysis and multiple regression analysis. 2. An extra amount was added to the waist measurement and external capsule measurement according to the number of times the pleats coincided and the thickness of the fabric by the degree of polymerization of the horizontal cross section (the test of this research: 0.518mm). The extra amount of waist measurement was 3.6cm while the hip measurement was 4.3cm larger than the hip measurement combined with the external capsule measurement and the extra amount. 3. Based on the ${\pm}$standard deviation/2 as the average of the difference between the external capsule measurement and waist measurement, the subjects were classified into 3 somatotypes. Somatotype 1 presented an average total length of waist darts of 23.6cm while that of somatotype 2 was 26.2cm and that of somatotype 3 was 30.2cm. It has been confirmed that there is a significant difference among somatotypes in the total length of waist darts from the front center to the front side and the total length of waist darts from the side to the back center in terms of the average amount of waist darts for every 12 parts on the WL.

Performance Improvement of Wald Test for Resolving GPS Integer Ambiguity Using a Baseline-Length Constraint

  • Lee Eun-Sung;Chun Se-Bum;Lee Young-Jae;Kang Tea-Sam;Jee Gyu-In;Abdel-Hafez Mamoun F.
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.333-343
    • /
    • 2006
  • In this paper, the baseline-length information is directly modeled as a measurement for the Wald test, which speeds up the resolution convergence of the integer ambiguity of GPS carrier phase measurements. The convergent speed improvement is demonstrated using numerical simulation and real experiments. It is also shown that the integer ambiguities can be resolved using only four actual satellite measurements with very reasonable convergence speed, if the baseline-length information is used just like one additional observable satellite measurement. Finally, it is shown that the improvement of convergence speed of the Wald test is due to the increase of the probability ratio with the use of the baseline-length constraint.

A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan. (공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구)

  • Lee Kwang Myung;Ham Jin Sik
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

A Study on the Stabilization Scheme of Optical Source for Precision Measurement (정밀측정을 위한 안정된 광원에 관한 연구)

  • 김지대;서호성;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.265-271
    • /
    • 2003
  • This study is for the stable optical source in order to get the precision measurement, which contributes to help the laser frequency and the output to be settled. The laser optical frequency is changed by the length of resonance cavity. The length variation of the laser resonance amplitude is affected by the thermal expansion of that system. So, we try not only to adjust the temperature of the laser tube using the heater for fine length of resonance cavity, but also to maintain the fixed temperature of the resonance cavity for outputting the safe laser optical frequency. Therefore, we must take materials with the thermal expansion of the supporting system, which is closer to it of the laser resonance cavity. Using the materials, we can promote to stabilize the temperature of it. In advance, we also plan to get the settlement of the laser frequency and the output in the long km, optimizing and stabilizing the system.

  • PDF