• Title/Summary/Keyword: leakage problems

Search Result 545, Processing Time 0.037 seconds

Preparation and Characterization of Polymer Lubricating Bearings (고온용 폴리머 윤활 베어링의 특성 연구)

  • Han, Jong-Dae;Kim, Sang-Keun;Kim, Byung-Kwan
    • Tribology and Lubricants
    • /
    • v.24 no.4
    • /
    • pp.179-185
    • /
    • 2008
  • Microporous polymer lubricants(MPLs) are solid polymer materials containing micropores which are filled with liquid lubricants, and which are molded or formed to suit rolling bearings or other machine parts requiring lubrication. MPLs can be effectively applied to provide long-term, maintenance-free lubrication of a variety of machine elements without fully replacing of oils and greases. The application of rolling bearings packed fully with an MPL could reduce or eliminate the problems such as grease deterioration, leakage, under-lubrication caused by insertion of water or foreign matters under severe operation conditions. This paper discuss the application of MPLs for lubrication of rolling ball bearings. Two different MPLs were synthesized and the features of MPLs were tested. Characteristics of the bearings which are packed fully with synthesized MPLs were investigated using SEM, TG/DSC, extents of oil leakage, OIT, and life time test. After these preliminary tests twelve MPLs were synthesized and evaluated by measuring extents of oil leakage and OIT values. Then synthesis conditions for the optimum MPL were selected by SSRED(Six Sigma Robust Engineering Design) pro gram using extents of oil leakage and OIT values respectively. The optimum MPL by means of OIT value showed higher performance such as long life time and application at higher temperature of $140^{\circ}C$ than previous temperature of $100^{\circ}C$.

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.

Study on Improved Detection Rule Formation via Information Leakage Malware Analysis (정보유출 악성코드 분석을 통한 개선된 탐지 규칙 제작 연구)

  • Park, Won-Hyung;Yang, Kyeong-Cheol;Lee, Dong-Hwi;Kim, Kui-Nam J.
    • Convergence Security Journal
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • Not only the recent hacking techniques are becoming more malicious with the sophisticated technology but also its consequences are bringing more damages as the broadband Internet is growing rapidly. These may include invasion of information leakage, or identity theft over the internet. Its intent is very destructive which can result in invasion of information leakage, hacking, one of the most disturbing problems on the net. This thesis describes the technology of how you can effectively analyze and detect these kind of E-Mail malicious codes. This research explains how we can cope with malicious code more efficiently by detection method.

  • PDF

Design of a Novel Integrated L-C-T for PSFB ZVS Converters

  • Tian, Jiashen;Gao, Junxia;Zhang, Yiming
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.905-913
    • /
    • 2017
  • To enhance the zero-voltage switching (ZVS) range and power density of the phase-shift full-bridge (PSFB) ZVS converters used in geophysical exploration, an additional resonant inductor is used as a leakage inductance and a blocking capacitor which is equivalent to interlayer capacitance is integrated into a novel integrated inductor-capacitor-transformer (L-C-T). The leakage inductance and equivalent interlayer capacitance of the novel integrated L-C-T are difficult to determine by conventional methods. To address this issue, this paper presents accurate and efficient methods to compute the leakage inductance and equivalent interlayer capacitance. Moreover, the accuracy of this methodology, which is based on electromagnetic energy and Lebedev's method, is verified by an experimental analysis and a finite element analysis (FEA). Taking the problems of the novel integrated L-C-T into consideration, the losses of the integrated L-C-T are analyzed and the temperature rise of the integrated L-C-T is determined by FEA. Finally, a PSFB ZVS converter prototype with the novel integrated L-C-T is designed and tested.

The Experimental Study on the Leakage of Automatic Pressure Differential·Overpressure Control Dampers by Increasing the Number of Damper Operation (자동차압·과압조절형댐퍼의 개폐동작횟수 증가에 따른 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.56-61
    • /
    • 2016
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of above 40 Pa, but pressure differential is excessively overpressure in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by increasing the number of dampers operation for identifying this problems. The result of testing, the leakage has difference between new dampers and increased the number of operation dampers. As the static preassure increase, the leakage difference increase. Comparison with preceding study, this result has similar linear tendency.

The Experimental Study on the Leakage of Automatic Pressure Differential · Overpressure Control Dampers (자동차압 · 과압조절형댐퍼의 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.71-75
    • /
    • 2015
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of 40 Pa~60 Pa, but pressure differential is over 60 Pa in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by testing for identifying this problems. The result of testing, leakage is $0.090m^3/s{\sim}0.154m^3/s$. It is necessary to limit the leakage of dampers for safe of escapers.

Experimental Study on the Safety of a Valve for a Special Gas Cylinder (특수가스용기용 밸브의 안전성에 관한 실험적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • This paper presents an experimental study on the safety of a valve for a special gas cylinder. The test valves that were randomly dismantled from the special gas cylinder were experimented on the gas leakage and operation safeties. The crack, wear and deformation of the valve body, screw thread, safety disk, vent hole, stem and handle components that may affect to the gas leakage safety of a used valve were not found in this experimental study. A painted handle of a valve was partly stripped from the coated surface, and the surface of PT screw of a used valve body was rusted. But, these paint and rust problems do not affected to the gas leakage safety of used valves. And there was no gas leakage in the dismantled valve, and the permanent deformation and partial scars of a valve stem and O-rings were observed on the rubbing surfaces. Thus, the valve seat and O-rings are recommended to be replaced for a gas leakage safety of a dismantled valve. And it is necessary to repair and inspect handle fastening forces for a safe opening and closing operations of a valve.

Reduction of EMI Generated by a PWM Inverter-Fed AC Motor Dirve System

  • Ogasawara, Satoshi;Akagi, Hirofumi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.452-457
    • /
    • 1998
  • This paper deal with problems of leakage current, shaft voltage, bearing current, and EMI, in valiable-speed AC drives. The originating mechanism is illustrated with a high-frequency equivalent circuit. Reduction methods are classified in to six categories based on the equivalent circuit. Some experimental results show that a common-mode transformer (CMT) and a common-noise canceler (ACC) can solve the problems, which have been proposed the authors.

  • PDF

Hardware Design and Deployment Issues in UHF RFID Systems

  • Jang, Byung-Jun;Yoon, Hyun-Goo;Lim, Jae-Bong
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • In this paper, we discuss hardware design and deployment issues in current passive UHF RFID systems. Using the link budget concept, the methodology to calculate forward- and reverse-link interrogation range is shown. Then, we consider hardware issues: phase diversity, phase noise with range correlation, and TX leakage problems. Finally, three interference problems when deploying RFID systems are presented.

A Study on Measuring Leaky Waves of Outdoor CATV Facilities in The Mobile Band (800MHz 이동통신 대역에서의 유선방송 전송설비 누설전자파 측정방법에 관한 연구)

  • Park, Seong-Gyoon
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • Cable leakage criterion of technical regulations on CATV transmission system was reinforced considering interference against CDMA mobile communication system in 2007. The criterion is $3{\mu}V$/m(at 10m) over 824~849MHz. But generally it is difficult for us to decide if a given CATV transmission facilities conform to it or not through simple measurement methods. In this paper, the problems on measuring cable leakage is identified theoretically and the measuring model with spectrum analyzer, LNA, and antenna is proposed to settle the problems. Also, the model is proved to be useful by practically measuring outdoors and analysing the results and the process to decide to fit to the criterion or not is established.