• Title/Summary/Keyword: leakage point

Search Result 333, Processing Time 0.027 seconds

Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: I. Variations of Electrical Properties of Subsurface due to Contaminants (전기저항 측정기법을 이용한 오염물질 누출감지시스템의 개발: I. 오염물질에 의한 지반의 전기적 특성 변화)

  • 오명학;박준범;김영진;홍성완;이용훈
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.215-224
    • /
    • 2001
  • The concept that the electrical properties of subsurface material can be affected by the introduction of contaminants might be applicable fur developing the leakage detection system for petroleum hydrocarbons of underground storage tanks and leachate coming from landfill. Investigations were conducted with diesel, NaCl solution, and leachate by laboratory tests. Simulation test was performed leaking at a certain point in the field. The measured resistance was exponentially decreased as the water content of uncontaminated unsaturated sand was increased. The resistance of soil was increased by diesel but decreased by NaCl solution or leachate. The optimum electrode spacings were found for NaCl solution, leachate and diesel. Electrolytic solutions were better detected by wider spacing than non electrolytic solution.

  • PDF

A High Efficiency Reconfigurable Doherty Amplifier (고효율의 재구성된 도허티 증폭기)

  • Kim, Ell-Kou;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.3
    • /
    • pp.220-226
    • /
    • 2008
  • This paper proposes the Reconfigurable Doherty Amplifier(RDA) with asymmetric structure which has ${\lambda}/4$ impedance transformer for modulating the load impedance in peaking amplifier path. This structure is possible to implement a compact size for N-stage multi Doherty amplifier and to get almost same characteristics that is compared to conventional Doherty amplifier. To realize the high efficiency amplifier, we were implemented 45 Watts power amplifier at transmitter band of Wideband Code Division Multiple Access(WCDMA) base-station. As a result, in case of WCDMA 1 Frequency Allocation(FA) input signals, this amplifier has obtained a 26.3% Power Added Efficiency(PAE) at 8 dB back-off point from P1dB and an Adjacent Channel Leakage Power(ACLR) is -40.4 dBc at center frequency ${\pm}5MHz$ deviation.

  • PDF

Experimental Study on the Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan (엇회전식 축류팬의 비정상 유동특성에 관한 실험적 연구)

  • Cho, Lee-Sang;Choi, Hyun-Min;Kang, Jeong-Seek;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.305-310
    • /
    • 2007
  • For the understanding of the complex flow characteristics in the counter-rotating axial flow fan, it is necessary to investigate the three-dimensional unsteady flow fields in the counter-rotating axial flow fan. This information is also essential for the prediction of the aerodynamic and acoustical characteristics of the counter-rotating axial flow fan. Experimental study on the three-dimensional unsteady flow in the counter-rotating axial flow fan is carried out at the design point(operating condition). Three-dimensional unsteady flow fields in the counter rotating axial flow fan are measured at the cross-sectional planes of the upstream and downstream of each rotor using the $45^{\circ}$ inclined hot-wire. Three-dimensional unsteady flow fields in the counter-rotating axial flow such as the wake, the tip vortex and the tip leakage flow are shown the form of the velocity vectors and the velocity contours.

  • PDF

A Study on Local Standard Complement Between the LED Signal Head and Traffic Controller for Improving Signal Safety (신호의 안전성 향상을 위한 교통신호기와 LED신호등의 연계 특성 개선 방안 연구)

  • Le, Choul-Ki;Lee, Jeong-Jun;Oh, Bong-Sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • The off-state impedance of LED signal head is greater than that of a traditional bulb signal head, and the traffic controller has inherent off-state output leakage current. These two characteristics make the field trouble and reduce signal safety when the LED signal head is installed with traffic controller. In this Paper, a complement method of the LED signal head and traffic controller local standard (220vac line voltage) for improving signal safety is suggested. The point of designed complement method is to reduce the output leakage current of the traffic controller under 3mA, to increase the voltage feedback threshold to $70{\pm}5V$, and to make LED signal head maintain off-state in 0-95vac with 10Kohm maximum impedance.

  • PDF

A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases (공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

Effect of Low-Temperature Sintering on Electrical Properties and Aging Behavior of ZVMNBCD Varistor Ceramics

  • Nahm, Choon-Woo
    • Korean Journal of Materials Research
    • /
    • v.30 no.10
    • /
    • pp.502-508
    • /
    • 2020
  • This paper focuses on the electrical properties and stability against DC accelerated aging stress of ZnO-V2O5-MnO2-Nb2O5-Bi2O3-Co3O4-Dy2O3 (ZVMNBCD) varistor ceramics sintered at 850 - 925 ℃. With the increase of sintering temperature, the average grain size increases from 4.4 to 11.8 mm, and the density of the sintered pellets decreases from 5.53 to 5.40 g/㎤ due to the volatility of V2O5, which has a low melting point. The breakdown field abruptly decreases from 8016 to 1,715 V/cm with the increase of the sintering temperature. The maximum non-ohmic coefficient (59) is obtained when the sample is sintered at 875 ℃. The samples sintered at below 900 ℃ exhibit a relatively low leakage current, less than 60 mA/㎠. The apparent dielectric constant increases due to the increase of the average grain size with the increase of the sintering temperature. The change tendency of dissipation factor at 1 kHz according to the sintering temperature coincides with the tendency of the leakage current. In terms of stability, the samples sintered at 900 ℃ exhibit both high non-ohmic coefficient (45) and excellent stability, 0.8% in 𝚫EB/EB and -0.7 % in 𝚫α/α after application of DC accelerated aging stress (0.85 EB/85 ℃/24 h).

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

A Rapid Convergent Max-SINR Algorithm for Interference Alignment Based on Principle Direction Search

  • Wu, Zhilu;Jiang, Lihui;Ren, Guanghui;Wang, Gangyi;Zhao, Nan;Zhao, Yaqin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1768-1789
    • /
    • 2015
  • The maximal signal-to-interference-plus-noise ratio (Max-SINR) algorithm for interference alignment (IA) has received considerable attention for its high sum rate achievement in the multiple-input multiple-output (MIMO) interference channel. However, its complexity may increase dramatically when the number of users approaches the IA feasibility bound, and the number of iterations and computational time may become unacceptable. In this paper, we study the properties of the Max-SINR algorithm thoroughly by presenting theoretical insight into the algorithm and by providing the potential of reducing the overall computational cost. Furthermore, a novel IA algorithm based on the principle direction search is proposed, which can converge more rapidly than the conventional Max-SINR method. In the proposed algorithm, it searches along the principle direction, which is found to approximately point to the convergence values, and can approach the convergence solutions rapidly. In addition, the closed-form solution of the optimal step size can be formulated in the sense of minimal interference leakage. Simulation results demonstrate that the proposed algorithm outperforms the conventional minimal interference leakage and Max-SINR algorithms in terms of the convergence rate while guaranteeing the high throughput of IA networks.

The Comparision of X-ray Detection Characteristics as Additive ratio of As in a-Se of $BrO_2/a-Se$ Film ($BrO_2/a-Se$ 필름의 a-Se에 첨가된 As 변화에 따른 X선 검출특성 비교)

  • Park, Ji-Koon;Choi, Jang-Yong;Kim, Dae-Hwan;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.424-427
    • /
    • 2002
  • In this papaer, there is a basic research for the development of the Hybrid digital radiation detector with a new system, make up for existing digital radiation detector of direct/indirect method with a weak point. for enhance the efficiency characteristics of signal response from X-ray detector using the a-Se, We make sample with various kinds of layer, through the ratio of As(0.l%,0.3%,0.5%,1%,1.5%,5%,10%). We measure net charge with a leakage current and photo current for electric charateristics. Ratio of As in a-Se consist of 7 stage, It made of using the thermal deposition system, In the made of samples, we made multi layer using the EFIRON optical adhesives from phosphor layer consist of Oxybromide$(BrO_2)$. As a result of X-ray measurement, the best result is ; leakage current(0.30nA/cm2), net charge(610.13pC/cm2/mR) when the condition is voltage(9V/um), 0.3% ratio of As in multi layer(BrO2 + a-Se)

  • PDF

Development of Privacy Impact Assessment Tool (개인정보 영향평가 툴 개발)

  • Heo, Jin-Man;Woo, Chang-Woo;Park, Jung-Ho
    • The Journal of Korean Association of Computer Education
    • /
    • v.15 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • As the number of web users is increasing, the leakage of personal information is increasing. If some personal information is leaked, the victim can suffer from material damage or mental damage at the same time. Most of the leakages are result from the people who works for the personal information by accident or design. Hence, the Ministry of Public Administration and Security proposeed the measuring index and enumerates the details. The index is used in a system to check protection of a personal information. However, because this system is used to evaluate after the leakage, it cannot be used to construct some security system or programming a security system. To solve this problem, it needs to express the diversity of items and be able to count what assessors want to count. Thus, a summary sheet which displays the result of the tool will be presented in a radial form graph. Details will be presented as a bar graph. Therefore, it will be proposed that the tool can grasp the weak point and propose the direction of security.

  • PDF