• Title/Summary/Keyword: leakage environment

Search Result 586, Processing Time 0.027 seconds

Detection Framework for Advanced and Persistent Information Leakage Attack (지능적이고 지속적인 정보유출 공격 탐지 프레임워크)

  • Kil, Ye-Seul;Jeon, Ga-Hye;Lee, Il-Gu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.203-205
    • /
    • 2022
  • As digital transformation and remote work environment advanced by Covid-19 become more common, the scale of leakage damage to industrial secrets and personal information caused by information leakage attacks is increasing. Recently, advanced and persistent information leakage attacks have become a serious security threat because they do not quickly leak large amounts of information, but continuously leak small amounts of information over a long period of time. In this study, we propose a framework for detecting advanced and persistent information leakage attacks based on traffic characteristics. The proposed method can effectively detect advanced and persistent information leakage attacks using traffic patterns, packet sizes, and metadata, even if the payload is encrypted.

  • PDF

A Preliminary Study for the Prediction of Leaking-Oil Amount from a Ruptured Tank (파손된 기름 탱크로부터의 유출양 산정을 위한 기초 연구)

  • Kim Wu-Joan;Lee Young-Yeon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.21-31
    • /
    • 2001
  • When an oil-spilling accident occurs at sea, it is of the primary importance to predict the amount of oil leakage for the swift response and decision-making. The simplest method of oil-leakage estimation is based on the hydrostatic pressure balance between oil inside the tank and seawater outside of leakage hole, that is the so-called Torricelli equilibrium relation. However, there exists discrepancy between the reality and the Torricelli relation, since the latter is obtained from the quasi-steady treatment of Bernoulli equation ignoring viscous friction. A preliminary experiment has been performed to find out the oil-leaking speed and shape. Soy-bean oil inside the inner tank was ejected into water of the outer tank through four different leakage holes to record the amount of oil leakage. Furthermore, a CFD (Computational Fluid Dynamics) method was utilized to simulate the experimental situation. The Wavier-Stokes equations were solved for two-density flow of oil and water. VOF method was employed to capture the shape of their interface. It is found that the oil-leaking speed varies due to the frictional resistance of the leakage hole passage dependent on its aspect ratio. The Torricelli factor relating the speed predicted by using the hydrostatic balance and the real leakage speed is assessed. For the present experimental setup, Torricelli factors were in the range of 35%~55% depending on the aspect ratio of leakage holes. On the other hand, CFD results predicted that Torricelli factor could be 52% regardless of the aspect ratio of the leakage holes, when the frictional resistance of leakage hole passage was neglected.

  • PDF

Detection of Personal Information Leakage using the Network Traffic Characteristics (네트워크 트래픽 특성을 이용한 개인정보유출 탐지기법)

  • Park, Jung-Min;Kim, Eun-Kyung;Jung, Yu-Kyung;Chae, Ki-Joon;Na, Jung-Chan
    • The KIPS Transactions:PartC
    • /
    • v.14C no.3 s.113
    • /
    • pp.199-208
    • /
    • 2007
  • In a ubiquitous network environment, detecting the leakage of personal information is very important. The leakage of personal information might cause severe problem such as impersonation, cyber criminal and personal privacy violation. In this paper, we have proposed a detection method of personal information leakage based on network traffic characteristics. The experimental results indicate that the traffic character of a real campus network shows the self-similarity and Proposed method can detect the anomaly of leakage of personal information by malicious code.

Energy Conversion Efficiency Improvement of Piezoelectric Micropower Generator Adopting Low Leakage Diodes (저누설 다이오드를 사용한 저전력 압전발전기의 효율 개선에 관한 연구)

  • Kim, Hye-Joong;Kang, Sung-Muk;Kim, Ho-Seong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.938-943
    • /
    • 2007
  • In this paper, we show that, in case of piezoelectric micropower generator, just replacing Schottky diodes in the bridge rectifier with ultra-low reverse leakage current diodes improves the mechanical-to-electrical energy conversion efficiency by more than 100%. Experimental and PSPICE simulation results show that, due to the ultra-low leakage current, the charging speed of the circuit employing PAD1 is higher than that of the circuit employing Schottky diodes and the saturation voltage of the circuit employing PAD1 is also higher. This study suggests that , when the internal impedance of source is very large (a few tens of $M{\Omega}$) such that maximum charging current is a few microamperes or less, in order to realize literally the energy scavenging system, ultra-low reverse leakage current diodes should be used for efficient energy conversion. Since low-level vibration is ubiquitous in the environment ranging from human movement to large infrastructures and the mechanical-to-electrical energy conversion efficiency is much more critical for use of these vibrations, we believe that the improvement in the efficiency using ultra-low leakage diodes, as found in this work, will widen greatly the application of piezoelectric micropower generator.

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Reactive transport modeling of the $CO_2-H_2O$-cement reaction in a $CO_2$ injection well for $CO_2$ geological storage ($CO_2$ 지중저장 주입정에서의 $CO_2-H_2O$-시멘트 반응 운송 모델링)

  • Jo, Min-Ki;Chae, Gi-Tak;Choi, Byoung-Young;Yu, Soon-Young;Kim, Tae-Hee;Kim, Jeong-Chan
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.359-370
    • /
    • 2010
  • $CO_2$ leakage from a geological formation utilized for $CO_2$ storage could result in failure of the facility and threaten the environment, as well as human safety and health. A reactive transport model of a $CO_2-H_2O$-cement reaction was constructed to understand chemical changes in the case of $CO_2$ leakage through a cement crack in an injection well, which is the most probable leakage pathway during geological storage. The model results showed the dissolution of portlandite and CSH (calcium silicate hydrate) within the cement paste, and the precipitation of secondary CSH and calcite as the $CO_2$ plume migrated along the crack. Calcite occupied most of the crack after 3 year of reaction, which could be maintained until 30 years after crack development. The present results could be applied in the development of technology to prevent $CO_2$ leakage and to enhance the integrity of wells constructed for $CO_2$ geological storage.

A Study on Implementation Method of ECM-based Electronic Document Leakage Prevention System through Security Area Location Information Management (보안구역 위치정보 관리를 통한 ECM기반 전자문서유출방지 시스템 구현방안 연구)

  • Yoo, Gab-Sang;Cho, Seung-Yeon;Hwang, In-Tae
    • Journal of Information Technology Services
    • /
    • v.19 no.2
    • /
    • pp.83-92
    • /
    • 2020
  • The current technology drain at small and medium-sized enterprises in Korea is very serious. According to the National Intelligence Service's survey data, 69 percent of technology leaks are made through employees of small and medium-sized enterprises. A document security system was introduced to compensate for the problem. However, small and medium-sized enterprises are not doing well due to their poor environment. Therefore, it proposes a document security system suitable for small businesses by developing a location information machine learning system that automatically creates a document security Green Zone through learning, and an ECM-based electronic document leakage prevention system that manages generated Green Zone information by reflecting it into the document authority system. And step by step, propose a universal solution through cloud services..

Mechanical Face Seal Performance Test for 75ton Class Turbopump (75톤급 터보펌프 기계평면 실의 작동 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.187-191
    • /
    • 2009
  • A leakage performance test and an endurance performance test of a 75 ton class turbopump mechanical face seal are performed using water under high speed and high temperature environment. A prototype mechanical face seal is manufactured for the purpose of sealing of fuel between a fuel pump and turbine. By simulating operating condition experimentally, the leakage rate and seal carbon wear rate are obtained to evaluate the performance of the prototype mechanical face seal. The test results show the acceptable leakage performance and reasonable wear tendency as well.

A Study on the Security Management System for Preventing Technology Leakage of Small and Medium Enterprises in Digital New Deal Environment

  • Kim, Sun-Jib
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.355-362
    • /
    • 2021
  • Through the Korean version of the New Deal 2.0, manufacturing-oriented SMEs are facing a new environmental change called smart factory construction. In addition, SMEs are facing new security threats along with a contactless environment due to COVID-19. However, it is practically impossible to apply the previously researched and developed security management system to protect the core technology of manufacturing-oriented SMEs due to the lack of economic capacity of SMEs. Therefore, through research on security management systems suitable for SMEs, it is necessary to strengthen their business competitiveness and ensure sustainability through proactive responses to security threats faced by SMEs. The security management system presented in this study is a security management system to prevent technology leakage applicable to SMEs by deriving and reflecting the minimum security requirements in consideration of technology protection point of view, smart factory, and remote access in a non-contact environment. It is also designed in a modular form. The proposed security management system is standardized and can be selectively used by SMEs.

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure (습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구)

  • 강효진;우영제;강호경;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF