• 제목/요약/키워드: leakage detection

검색결과 457건 처리시간 0.037초

IoT를 기반한 조명설비 누전사고 감지시스템에 관한 연구 (A Study on the Leakage Current Detection System of Lighting Installation Using IoT Technology)

  • 박근영;곽동걸;이봉섭;김춘삼;전호진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2018
  • In this study, we develop a leakage current detection device of lighting installation. The reed switch using in proposed device is activated when the leakage current is generated. We also design a GUI system of a management computer using LabVIEW and administrator's mobile phone app based on IoT. As results, this study is to build an IoT convergence system and it aims to protect people and property by coping with leakage current fault in real time.

  • PDF

네트워크 트래픽 특성을 이용한 개인정보유출 탐지기법 (Detection of Personal Information Leakage using the Network Traffic Characteristics)

  • 박정민;김은경;정유경;채기준;나중찬
    • 정보처리학회논문지C
    • /
    • 제14C권3호
    • /
    • pp.199-208
    • /
    • 2007
  • 유비쿼터스 네트워크 환경에서 개인정보의 유출은 다양한 사이버 범죄를 야기하며 개인정보의 상품화로 프라이버시의 침해가 증가하므로 개인정보의 유출을 탐지하는 것은 매우 중요하다. 본 논문은 네트워크의 트래픽 특성을 기반으로 한 개인정보 유출 탐지 기법을 제안하고자 한다. 실제 대학망에서 정상 상태의 트래픽을 수집하여 트래픽의 특성을 분석함으로써 네트워크 트래픽이 자기유사성을 지님을 확인하였다. 개인정보의 유출을 시도하는 악성코드의 사전정보수집단계를 모사한 비정상적인 트래픽에 대하여 정상 트래픽에서의 자기유사성과의 변화를 살펴봄으로써 이상을 조기 감지할 수 있었다.

주파수 도약 신호 탐지에 최적화된 탐지 확률 향상 기법 (Detection Probability Improvement Scheme Optimized for Frequency-Hopping Signal Detection)

  • 이인석;오성준
    • 한국전자파학회논문지
    • /
    • 제29권10호
    • /
    • pp.783-790
    • /
    • 2018
  • 주파수 도약(frequency hopping) 기법은 대역확산(spread spectrum) 방법 중 하나로, 광대역 상에서 반송파의 주파수가 고정되어 있지 않고, 다양한 주파수 채널로 도약하는 통신방식이다. 이러한 특성으로 인해 뛰어난 항재밍 성능, 낮은 탐지율 등의 장점을 가지고 있어, 군 통신에 자주 사용되고 있으며, 상용 통신에도 종종 사용되고 있다. 바꿔 말하면, 이런 주파수 도약 신호를 잘 탐지해내는 것은 매우 어려우며 중요한 연구분야 중 하나이다. 본 논문에서는 FFT를 이용한 신호 탐지를 할 때, 주파수 도약 신호의 탐지율을 증가시킬 수 있는 기법을 제안한다. 수신한 신호를 FFT를 이용하여 주파수 성분으로 변환시킬 경우, 스펙트럼 누설(spectral leakage)이 발생하여 탐지율이 낮아진다. 이때, 해밍 윈도우(hamming window)를 이용하여 문제를 해결하고 탐지율을 증가시킬 수 있는데, 주파수가 도약하는 환경에서는 윈도우가 오히려 성능 저하를 가져오기도 한다. 제안하는 기법은 주파수 변화에 대응하여 이러한 약점을 해결하였으며, 기존에 비해 최대 13 % 정도의 탐지율 향상을 얻을 수 있다.

침수 누전에 대한 자계 특성

  • 김탁용;이경섭;김진사;김충혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.147-147
    • /
    • 2009
  • Every year respect a countermeasure establishment the electric leakage detection system and electric leakage investigation work are becoming enforcement line plentifully in about the electric leakage accident which is increasing, measuring in compliance with a most ground connection voltage and an image electric current mainly is become accomplished, inputs a pulsation group signal in the line and detects a signal change between the line a method which there is. In order to investigate the quality in compliance with an electric leakage electric current from the electric leakage area after conferring the electric leakage environment in compliance with a flooding when the electric leakage electric current exists in the surface, it investigated the electric leakage electric current quality from the electric current distribution and flooded districts from the present paper.

  • PDF

누수탐지를 위한 천이류와 주착수분석 적용 연구 (Application of Transient and Frequency Analysis for Detecting Leakage of a Simple Pipeline)

  • 김형근;김현수;이미현;김상현
    • 대한환경공학회지
    • /
    • 제27권10호
    • /
    • pp.1065-1071
    • /
    • 2005
  • 유체의 파속과 파형을 이용한 많은 누수탐지 기술들이 연구되고 있다. 본 연구에서는 파속을 계산하기 위해 천이류 방법을 이용하였고 누수지점의 탐지를 위해 주파수 분석방법을 개발하였다. 가압관망의 자료획득 시스템을 개발하였으며, 이를 통해 고주파 수압자료를 획득하였다. 이들 방법론은 측정과 모의 과정에서 발생되는 오차로 인한 불화실성을 적절히 처리할 수 있으며, 수압자료의 측정간을 근거로 누수의 예측지점을 추정할 수 있다. 본 연구에서 개발된 방법은 수압자료로부터 확보되는 정보를 기반으로, 누수가 동반된 천이현상에서 누수예측능력을 보여주고 있다.

Transient Analysis and Leakage Detection Algorithm using GA and HS algorithm for a Pipeline System

  • Kim Sang-Hyun;Yoo Wan-Suk;Oh Kwang-Jung;Hwang In-Sung;Oh Jeong-Eun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.426-434
    • /
    • 2006
  • The impact of leakage was incorporated into the transfer functions of the complex head and discharge. The impedance transfer functions for the various leaking pipeline systems were also derived. Hydraulic transients could be efficiently analyzed by the developed method. The simulation of normalized pressure variation using the method of characteristics and the impulse response method shows good agreement to the condition of turbulent flow. The leak calibration could be performed by incorporation of the impulse response method with Genetic Algorithm (GA) and Harmony Search (HS). The objective functions for the leakage detection can be made using the pressure-head response at the valve, or the pressure-head or the flow response at a certain point of the pipeline located upstream from the valve. The proposed method is not constrained by the Courant number to control the numerical dissipation of the method of characteristics. The limitations associated with the discreteness of the pipeline system in the inverse transient analysis can be neglected in the proposed method.

정보유출 악성코드 분석을 통한 개선된 탐지 규칙 제작 연구 (Study on Improved Detection Rule Formation via Information Leakage Malware Analysis)

  • 박원형;양경철;이동휘;김귀남
    • 융합보안논문지
    • /
    • 제8권4호
    • /
    • pp.1-8
    • /
    • 2008
  • 최근 해킹 기법들은 기존보다 정교한 기술을 바탕으로 악성화 되어 그 피해 규모가 증가하고 있으며, 인터넷 사용자의 확대와 맞물려 그 위력은 커지고 있다. 특히 정보유출을 목적으로 제작한 해킹메일에 첨부된 악성코드의 피해가 급증하고 있다. 본 논문에서 이러한 정보유출형 악성코드를 효과적으로 분석, 탐지할 수 있는 기술에 관하여 연구한다. 또한 본 연구에서는 기존 악성코드의 탐지규칙과 해킹메일 악성코드 탐지규칙을 비교하였으며 이를 통해 해킹메일 악성코드 뿐 아니라 새로운 악성코드와 변종들에 대해서도 탐지할 수 있는 기술에 대해 설명한다.

  • PDF

편로드 유압실린더 내부 누유 검출을 위한 T—S 퍼지 모델 기반 샘플치 관측기 설계: LMI 접근법 (T—S Fuzzy Model-based Sampled-data Observer Design for Detecting Internal Oil Leakage in Single-rod Hydraulic Cylinder: LMI Approach)

  • 지성철;김효곤;박정우;이문직;강형주;이계홍
    • 한국해양공학회지
    • /
    • 제30권5호
    • /
    • pp.405-414
    • /
    • 2016
  • This paper presents an internal oil leakage detection problem for a hydraulic single-rod cylinder. We derive the dynamics of the hydraulic cylinder as a state space model, and then design a T—S fuzzy model-based fault detection observer. We adopt an H observer design scheme so that the observer is robust against disturbance and relatively sensitive to the leakage fault. Sufficient design conditions are derived in the form of linear matrix inequalities. A numerical example is provided to verify the proposed techniques.

API간 상호 의존성 및 최단거리 분석을 통한 안드로이드 애플리케이션의 개인정보 유출 탐지 기법 (Detection of Privacy Information Leakage for Android Applications by Analyzing API Inter-Dependency and the Shortest Distance)

  • 김도래;박용수
    • 정보과학회 논문지
    • /
    • 제41권9호
    • /
    • pp.707-714
    • /
    • 2014
  • 스마트폰 사용자에게 서비스를 제공하기 위해 정상 앱은 특정 개인정보를 외부로 전달하는 행위를 하며, 이러한 정상 앱의 행위는 악성 앱과 행위 측면에서 유사한 면을 지닌다. 즉, 정상 앱을 악의적인 목적으로 일부 조작한다면, 정상 앱은 쉽게 악성 앱으로 변조될 수 있다. 때문에 정상 앱이라 할지라도 개인정보의 유출 가능성을 사용자에게 앱 설치 이전에 경고해서 잠재적인 악의적 행위를 예방하는 것이 중요하다. 본 논문에서는 추출된 API간 상호의존성 정보 내부에서 개인정보 탈취 및 유출 노드사이의 최단거리를 계산하여 개인정보 유출의 가능성을 지닌 의심스러운 일반 앱 탐지 방법을 제안한다. 또한 제안방법을 적용시켜 "LeakDroid"를 구현하였으며, 이를 검증하기 위해 악성 앱 250개와 일반 앱 1700개를 사용하여 실험을 진행하였다. 실험결과 악성 앱은 96.4%의 탐지율을 달성하였고, 일반 앱은 1700개중 실제 68개의 앱에서 개인정보 유출을 의심할 수 있는 흐름을 확인하였다.

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.