• Title/Summary/Keyword: leakage current test

Search Result 226, Processing Time 0.026 seconds

A Study on Performance Evaluation of SPD Varistor by Temperature Measurement(I) (온도측정에 의한 SPD용 배리스터의 성능평가에 관한 연구(I))

  • Yeo, In-Sik;Ko, Young-Min;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.490-494
    • /
    • 2009
  • In this paper, how the temperature of a varistor changes when $10/350{\mu}s$ surge currents and/or DC leakage currents are applied on it, respectively, are investigated. The temperature change in varistor is related with injection energy and leakage current. which is the integration of power in time. By the surge current test, we found that the temperature jump is proportional to the level of surge current with slant 52.535 and has no relation with the ambient temperature. And by the DC leakage current test, the difference in temperatures between varistor and ambient is proportional to the magnitude of leakage current. The slope of measured line(the temperature difference vs. the leakage current) shows alteration around $100{\mu}A$. The varistors can not be used more than $100{\mu}A$ region any more. From the above experimental results, we can conclude that data of the surge current test and also those of DC leakage current test can predict the performance of varistors of which the surge protective devices are made.

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

The Study of Leakage Current Distributions of Plymeric Insulators will Changing Environment (주위 환경 변화 따른 폴리머 절연재료의 표면 누설전류)

  • 이병성;한재홍;김주용;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.88-91
    • /
    • 2001
  • Our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate leakage current patterns caused by surface aging on polymeric insulators, we utilized the combined aging test facility and leakage current monitoring system. And we get the continuous leakage current values from each sample. After completing the 3000h combined aging cycle test, leakage current measurement were conducted for these samples and carried out harmonics analysis for its data.

  • PDF

Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test (가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석)

  • Kim, Ju-Yong;Song, Il-Geun;Kim, Chan-Yeong;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line (전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis (피뢰기 열화진단을 위한 저항분 누설전류의 측정장치)

  • 길경석;한주섭;김정배
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

Accelerating aging test of distribution lightning arresters (배전용 피뢰기의 가속열화시험)

  • 김주용;송일근;김찬영;이병성;문재덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.596-598
    • /
    • 2000
  • This paper presents a new accelerating aging test facility for distribution lightning arresters. Aging parameters of lightning arrester are moisture ingress, electrical stress and surge absorption and so on. In this system, we applied 13.2kV to 6 samples and controled temperature and humidity of chamber and measured leakage currents of the all samples. Also we developed accelerating aging cycle which consists of -35$^{\circ}C$∼90$^{\circ}C$ temperature and 40%∼90% humidity. Through the aging test we found out the leakage current of aged sample increases rapidly according to the temperature rising. Hereafter we can determine the replacement guide of leakage current for field operating arresters and condition assessment of aged samples through this aging test.

  • PDF

Study for Measurement of Polluted Outdoor Insulations Using Leakage Current (누설전류 측정을 통한 옥외절연물 오손도 측정)

  • Lee, Bu-Won;Kim, Sung-Jung;Park, Woo-Yong;Kim, Young-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2068-2069
    • /
    • 2007
  • This study describes a compairison leakage current properties between a polluted insulator and insulator subjected to salt polluted condition. Exposure tests at a sea coast test and the leakage current of insulators, climate conditions, and salt deposit density were measured during the tests. Appearance of leakage current for the insulator was affected by the humidity and the salt deposition on the surface. comparison of leakage current under salt polluted conditions. salt polluted test and humidity tests were carried out in laboratory using the same insulator profiles in oder to determine the leakage current patterns during critical conditions

  • PDF

High Temperature Characteristics of submicron GaAs MESFETs (고온 동작 MESFET 의 온도특성 해석)

  • 원창섭;유영한;신훈범;한득영;안형근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.379-382
    • /
    • 2002
  • GaAs has wide band gap, Therefore that malarial can used high Temperature application. in this paper explain to current-voltage characteristics of thermal effect. we experiment on thermal test of current-voltage characteristics and gate leakage current with real device. As a result, we propose a current-volatage characteristics model. that model base on gate leakage current, and gate leakage current influence gate source voltage.

  • PDF

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.