• Title/Summary/Keyword: lead plate

Search Result 311, Processing Time 0.028 seconds

Effects of Curing Conditions on the Chemical Compositions of Positive Plate for Lead Acid Battery Plates (납축전지 극판의 숙성 조건이 양극판의 화학적 조성에 미치는 영향)

  • Ku, Bon-Keun;Jeong, Soon-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.347-354
    • /
    • 2006
  • Generally, it has been known that positive plate efficiency is the most influential effect on the initial current capacity of lead acid battery. Thus, in this study, we have investigated the curing effect of the positive plate, which is one of the important lead acid battery processes. The curing process of the positive plate is performed either with the separation of each plate with 1mm gap or with no gap of plate. As a result, when there is no interval between each plate, the higher temperature current happened than expected, resulting in the changes in the initial current efficiency of the lead acid battery. The chemical composition and crystal structure of a material coated on the positive plate were identified with XRD and SEM. It was resulted that were only there not a lot of 4BS (tetrabasic-lead sulfate, $4PbO{\cdot}PbSO_4)$ on the plate in case of curing of plates without interval, but a large quantity of $Pb_3O_4$ also formed on the surface. On the other hand, it was observed that 3BS (tribasic-lead sulface, $3PbO{\cdot}PbSO_4{\cdot}H_2O)$ was the main product on the plate in case of typical curing process with some interval. From the initial current capacity test, the positive plate having 3BS was approximately 40% higher in initial current capacity than that having 4BS. It was concluded that 4BS and $Pb_3O_4$ on the plate surface were harmful to the initial current capacity of lead acid battery.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

A Study on the Curing of Positive Plate and Grid to Improve the Capacity of the Lead-Acid Batteries (납축전지의 성능 향상을 위한 양극판의 숙성과 그리드에 관한 연구)

  • Ku, Bon-Keun;Jeong, Soon-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • This study was conducted to made a grid alloy (Pb-Ca-Sn-Al) which has a temporary composition ratio in order to improve the efficiency of lead acid batteries. The positive activity material made a 3BS(tri-basic lead sulfate; $3PbO{\cdot}PbSO_4{\cdot}H_2O$) by a low temperature curing and it evaluates the plate efficiency through the life cycle testing. The initial current capacity of low temperature curing plate was excellent but the life cycle was not good (S1). As for the S2 plate, however, the initial current capacity and the life cycle were superior.

A Study on the Plate for Deep Discharge in Lead Acid Battery (납축전지의 심방전용 극판에 관한 연구)

  • Jeong, Soon-Wook;Ku, Bon-Keun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.197-202
    • /
    • 2014
  • Positive plate was composed of lead hydroxide via reaction between lead oxide and $H_2O$ and lead sulfate was formed of the reaction of lead hydroxide with sulfuric acid. And its density is $3.8g/cm^3$, $4.0g/cm^3$, $4.2g/cm^3$ and $4.4g/cm^3$ by controlling volume of refined water. Curing of positive plate is done for low ($45^{\circ}C$, 40hr, over 95% of relative humidity) & high ($80^{\circ}C$, 40hr, over 95% of relative humidity) temperature, which created 3BS & 4BS active materials. Experimental result of DOD with 100% life cycle test shows that it was not related to the density of active materials but to the low & high temperature aging of active materials. The test makes us to understand that the crystallization which is made by curing of active materials is a more of a main factor than density of active materials under the deep cycle using circumstances. The active materials which were from the high temperature curing are better for deep cycle performance.

Effect of Curing on Positive Plate Behavior in Lead-Acid Battery (숙성조건에 따른 연축전지용 양극 극판의 특성 연구)

  • 김상필;남기윤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.177-181
    • /
    • 1995
  • Lead-acid battery is used widely as a power source in the automobile, industrial machines, folk lifts U.P.S etc. But this battery has man\ulcorner disadvantages such as heavy low energy density, environment problem etc. In this paper, we have studied the physicochemical and electrochemical properties of lead-acid battery positive plates with regard to the method of curing. It has been observed that curing conditions strongly influence electrode composition and electrchemical performance.

  • PDF

Direct Measurement of Blast Pressure in Near Field with Lead Plate Blast Pressure Meter (Lead Plate Blast Pressure Meter를 이용한 근거리 기폭의 발파압 계측)

  • Ko, Young-Hun;Jang, Hyong-Doo;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.22 no.1
    • /
    • pp.54-59
    • /
    • 2012
  • Deformation of Lead plate blast pressure meter were measured after they were exposed to surface blasting. Blasting pressure was determined by comparing the data with calibration graph which was drawn from the laboratory experiments with gas gun of Hopkinson bar tester. The results were compared with calculated values from the equations of CONWEP (Conventional Weapons Effects Program) and DDESB (Department of Defence Explosives Safety Board). Measured values were lower than calculated values in near field. Gradual decaying tendency of the pressure was observed. It means that estimated blasting pressure of very near field with theoretical equations can be uncertain.

A Study on the Pb-Ca-Sn Grid Alloy of Positive Plate in Lead-Acid Battery (납축전지에서 양극판의 Pb-Ca-Sn 그리드 합금에 관한 연구)

  • Ku, Bon-Keun;Jeong, Soon-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.518-524
    • /
    • 2008
  • In this study, positive plates of lead acid battery of Pb-Ca alloy and Pb-Ca-Sn alloy were fabricated and the mechanical characteristics of positive plates were measured. This study observed how the changes of content of Ca & Sn affect interface corrosion which is located in between grid & active materials and lead acid batteries as well. The mechanical characteristics of grid alloy is better when Ca is 0.05 wt.% then 0.1 wt.%. This study said that the corrosion rate between the active material based on the charge/discharge cycle of lead acid battery and grid interface is much faster than a grid which contains Sn. And furthermore, according to the study the rate 30 of Sn/Ca which is added to grid shows the best performance.

A Study on the Reduction of Scattered Ray in Outside Radiation Field (조사야 외부의 산란선량 감소 방법에 관한 연구)

  • Je, Jaeyong;Jang, Howon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.539-543
    • /
    • 2016
  • In this research, The way to decrease a patient's exposure dose by reducing the scattered radiation dosage outside a radiation field with an diagnosis X-ray was examined. The scattered radiation dosage reaching other parts outside the radiation field was to be reduced by attaching a self-produced $150{\times}190mm^2$ lead plate to the lower part of a collimator. When a lead plate was inserted additionally and the scattered radiation dosage of the X axis was measured in the direction of the central X-ray axis, It was found out to have been decreased by 26 to 36%, and in the direction of Y axis, which was vertical direction from the central axis, The scattered radiation dosage depending on whether a lead plate was used or not displayed no large differences. These results shows that the impact of the scattered radiation by the off focus X-ray that was generated around the focus was bigger than that generated by the shutter of the collimator. Therefore it has been concluded that installing an additional lead plate in the lower part of the existing collimator can decrease the scattered radiation dosage outside a radiation field.

Aerodynamic Analysis of a Rectangular Wing in Flapping with Lead-Lag Motion using Unsteady VLM (직사각형 평판날개의 리드래그 운동이 조합된 날개짓에 대한 비정상 VLM 공력 해석)

  • Kim, Woo-Jin;Kim, Hark-Bong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.14 no.2
    • /
    • pp.39-44
    • /
    • 2006
  • The unsteady vortex lattice method is used to model lead-lag in flapping motions of a rectangular flat plate wing. The results for plunging and pitching motions were compared with the limited experimental results available and other numerical methods. They show that the method is capable of simulating many of the features of complex flapping flight. The lift, thrust and propulsive efficiency of a rectangular flat plate wing have been calculated for various lead-lag motion and reduced frequency with an amplitude of flapping angle(20o). To describe a motion profile of wing tip such as elliptic, line and circle, the phase difference of flapping and lead-lag motion was changed. And the effects of the motion profile on the aerodynamic characteristics of the flapping wing are discussed by examination of their trends.

  • PDF

A Decision of the Production Control Policy using Simulation in Zinc Manufacturing Process (시뮬레이션을 이용한 아연공장의 생산통제 방안의 결정)

  • Kim, Jun-Mo;Kim, Yearn-Min
    • IE interfaces
    • /
    • v.21 no.4
    • /
    • pp.418-434
    • /
    • 2008
  • This paper studied issues in decision making on the production control policy of a cathode plate manufacturing process in zinc refining plant. The present production system has a long lead time from raw materials (aluminum plate) to products (cathode plate) due to many WIP inventories. Because WIP inventories are stocked at each process and moved from one place to another frequently, they are the main cause of inefficiency in the process. In this paper, to solve this problem, several production control policies have been identified and studied. Several simulation models are used to compare the performances of these production control policies. The output lead time and WIP (Work In Process) of real production system are compared with those of simulation models. PUSH, CONWIP, DBR, KANBAN and CONWIP-DBR models have been used to simulate and review the optimized production control policy that achieves the target output quantities with decreased lead time and WIP. The simulation results of each production control policy show that CONWIP and CONWIP-DBR models are the good production control policy under the present production system. Especially in present production system, CONWIP with one parameter is easier control policy than CONWIP-DBR with two parameters. Therefore CONWIP has been selected as the best optimum production control policy. With CONWIP, lead time has been reduced by 97% (from 6,653 to 187 minute) and WIP has been reduced from 1,488 to 53, compared to the present system.