• 제목/요약/키워드: lead particle

검색결과 260건 처리시간 0.024초

공기중 납입자의 크기 특성과 혈액중 납농도와의 관계에 의한 허용농도 측정 (Estimation of Occupational Health Standard by Relationship between Airborne Lead Concentration by Particle Size and Lead in Blood)

  • 박동욱;백남원
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.265-271
    • /
    • 1996
  • This study was conducted to investigate distribution of lead particles by operation of industry, to evaluate the effect of particle size on the absorption to workers, and to recommend the Occupational Health Standard for lead. Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Average blood lead level of workers was $85.1{\mu}g/dl$ in secondary smelting manufacturing, $51.3{\mu}g/dl$ in the battery manufacturing, and below $40{\mu}g/dl$ in the litharge and radiator manufacturing industry. Blood lead levels of workers by industry were significantly different(p<0.05). From relationship between airborne lead concentrations by size and lead in blood, confidence limits of airborne lead concentration equivalent to $40{\mu}g/dl$ of permissible limit in blood, was $147.9-489.8{\mu}g/m^3$ as total lead and $28.8-79.4{\mu}g/m^3$ as ACGIH-RPM. It is recommended that two separate occupational health standards for lead should be established by particle size. Airborne concentration of $150{\mu}g/m^3$ as fatal lead dust and $30{\mu}g/m^3$ as respirable lead dust was recommended.

  • PDF

Single-particle Characterization of Aerosol Particles Collected Nearby a Lead Smelter in China

  • Jung, Hae-Jin;Song, Young-Chul;Liu, Xiande;Li, Yuwu;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.83-95
    • /
    • 2012
  • China has been a top producer and exporter of refined lead products in the world since the year 2000. After the phasing-out of leaded gasoline in the late 1990s, non-ferrous metallurgy and coal combustion have been identified as potential major sources of aerosol lead in China. This paper presents the single particle analytical results of ambient aerosol particles collected near a lead smelter using a scanning electron microscopy- energy dispersive x-ray spectroscopy (SEM-EDX). Aerosol particle samples were collected over a 24-hour period, starting from 8 pm on 31 May 2002, using a high volume TSP sampler. For this near source sample, 73 particles among 377 particles analyzed (accounting for 19.4%) were lead-containing particles mixed with other species (S, Cl, K, Ca, and/or C), which probably appeared to be from a nearby lead smelter. Lead-containing particles of less than $2{\mu}m$ size in the near source sample were most frequently encountered with the relative abundances of 42%. SEM-EDX analysis of individual standard particles, such as PbO, PbS, $PbSO_4$, $PbCl_2$, and $PbCO_3$, was also performed to assist in the clear identification of lead-containing aerosol particles. Lead-containing particles were frequently associated with arsenic and zinc, indicating that the smelter had emitted those species during the non-ferrous metallurgical process. The frequently encountered particles following the lead-containing particles were mineral dust particles, such as aluminosilicates (denoted as AlSi), $SiO_2$, and $CaCO_3$. Nitrate- and sulfate-containing particles were encountered frequently in $2-4{\mu}m$ size range, and existed mostly in the forms of $Ca(NO_3,SO_4)/C$, $(Mg,Ca)SO_4/C$, and $AlSi+(NO_3,SO_4)$. Particles containing metals (e.g., Fe, Cu, and As) in this near source sample had relative abundances of approximately 10%. Although the airborne particles collected near the lead smelter contained elevated levels of lead, other types of particles, such as $CaCO_3$-containing, carbonaceous, metal-containing, nitrates, sulfates, and fly-ash particles, showed the unique signatures of samples influenced by emissions from the lead smelter.

업종별 공기중 납입자의 입경별 분포특성에 관한 조사 연구 (A Study on the Characteristic of Airborne Lead Particle Size by Industry)

  • 박동욱;백남원
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.160-171
    • /
    • 1995
  • The size characteristics of lead particle which is one of the important factors associated with absorption of lead were ignored in establishing lead standard. This study was conducted to investigate distribution of lead particles by operation of industry. Aerodynamic Mass Median Diameters (MMD) of airborne lead particles in the battery and litharge manufacturing industry were $14.1{\mu}m$ and $15.1{\mu}m$, respectively. There was no significant difference between those two values(p>0.05). However, the diameters in radiator manufacturing and secondary smelting industry were $1.3{\mu}m$, $4.9{\mu}m$, respectively. Those were significantly smaller than the particle sizes in other industries(p<0.05). Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Concentrations of lead particles smaller than $1{\mu}m$ defined as respirable fraction by OSHA's CPA model assumption were $72.4{\mu}g/m^3$ in the secondary smelting industry, exceeding $50{\mu}g/m^3$. The relationship of concentrations between total lead and lead of particles smaller than $1{\mu}m$ was log Y = 0.46 logX + 0.06(n=119, $r^2=0.44$, p=0.0001). Relationship of respirable lead concentrations between OSHA and ACGIH was significantly detected in the litharge and battery manufacturing industry(p=0.0001), but was not significant in the radiator(p=0.2720) and secondary smelting manufacturing industry(p=0.2394). As MMDs of lead particles generated in industry were small, difference of respirable lead concentration between OSHA and ACGIH became smaller. There was a significant difference between concentrations respirable lead defined by two organizations such as OSHA and ACGIH in the battery and litharge manufacturing industry. Average concentration of respirable lead by ACGIH definition was 43.3 % of total lead in secondary smelting and 48.9 % in radiator manufacturing industry, and lower fractions were indicated in battery and litharge manufacturing industry. Relationships of total lead with IPM, TPM, and RPM were significant respectively(p=0.0001) and lead concentrations by particle size could be estimated using this relationship. Linear regression equation between total lead concentration(X) and ACGIH-RPM concentration(Y) was log Y = 0.76 log X - 0.40($r^2=0.89$, p=0.0001).

  • PDF

Health Risk Assessment of Lead Ingestion Exposure by Particle Sizes in Crumb Rubber on Artificial Turf Considering Bioavailability

  • Kim, Sun-Duk;Yang, Ji-Yeon;Kim, Ho-Hyun;Yeo, In-Young;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • 제27권
    • /
    • pp.5.1-5.10
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the risk of ingestion exposure of lead by particle sizes of crumb rubber in artificial turf filling material with consideration of bioavailability. Methods: This study estimated the ingestion exposure by particle sizes (more than 250 um or less than 250 um) focusing on recyclable ethylene propylene diene monomer crumb rubber being used as artificial turf filling. Analysis on crumb rubber was conducted using body ingestion exposure estimate method in which total content test method, acid extraction method and digestion extraction method are reflected. Bioavailability which is a calibrating factor was reflected in ingestion exposure estimate method and applied in exposure assessment and risk assessment. Two methods using acid extraction and digestion extraction concentration were compared and evaluated. Results: As a result of the ingestion exposure of crumb rubber material, the average lead exposure amount to the digestion extraction result among crumb rubber was calculated to be $1.56{\times}10^{-4}$ mg/kg-day for low grade elementary school students and $4.87{\times}10^{-5}$ mg/kg-day for middle and high school students in 250 um or less particle size, and that to the acid extraction result was higher than the digestion extraction result. Results of digestion extraction and acid extraction showed that the hazard quotient was estimated by about over 2 times more in particle size of lower than 250 um than in higher than 250 um. There was a case of an elementary school student in which the hazard quotient exceeded 0.1. Conclusions: Results of this study confirm that the exposure of lead ingestion and risk level increases as the particle size of crumb rubber gets smaller.

양이온 물질로 오염된 지하수 정화를 위한 반응벽체 개발 : 제올라이트의 적용성 평가

  • 이승학;이재원;김시현;박준범;박상권
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.23-26
    • /
    • 2001
  • Batch test and column test were performed to develop the design factors for PRBs against the contaminated groundwater by ammonium and lead. Clinoptilolite, one of the natural zeolites having excellent cation exchange capacity(CEC), was chosen as the reactive material through the ion-exchange mechanism. In the batch test, the reactivity of Clinoptilolite to ammonium and lead was examined with varying the particle size of Clinoptilolite. The nit weight of Clinoptilolite showed removal efficiencies of 65 % against the ammonium and 98% against lead. The effect of particle size of Clinoptilolite was not noticeable. In the column test, the permeability was examined using flexible-wall permeameters with varying the particle size of Clinoptilolite. When the washed Clinoptilolite having the diameter of 0.42-0.85 nm was mixed with Jumunjin sands in 20:80 ratio (w/w), the highest permeability of 2$\times$10$^{-3}$ -7 x 10$^{-4}$ cm/s was achieved. The reactivity and the strength property of the mixed material were investigated using fixed wall column having 8 sampling ports on the wall and the direct shear test, respectively. Clinoptilolite was found to be a suitable material for PRBs against the contaminated groundwater with ammonium and/or heavy metals.

  • PDF

흡입독성 연구를 위한 2730ppm 납 네뷸라이징 용액에서 발생된 에어로졸의 입경분석 (Particle Size Analysis of Lead Aerosol with the use of 2730ppm Lead Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;강성호;김삼태;이은경;송용선;이기남
    • 동의생리병리학회지
    • /
    • 제17권2호
    • /
    • pp.518-524
    • /
    • 2003
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit was made for lead inhalation toxicology study and 2730ppm lead nebulizing solution was used to generate lead aerosol. After modification of source and inlet temperatures, the results of particle size analysis for lead aerosol were as following. The highest particle counting for source temperature 20℃ was 39933.66 in inlet temperature 100℃ and particle diameter 0.75tLm. The highest particle counting for source temperature 50℃ was 39992.71 in inlet temperature 250℃ and particle diameter 0.75μm. The highest particle counting for source temperature 70℃ was 37569.55 in inlet temperature 50℃ and particle diameter 0.75μm. The ranges of geometric mean diameter(GMD) were 0.754-0.784μm for source temperature 2℃, 0.758-0.852μm for source temperature 50℃, and 0.869-1.060μm for source temperature 70℃. The smallest GMD was 0.754μm in source temperature 20℃ and inlet temperature 20℃, and the largest GMD was 1.060μm in source temperature 70℃ and inlet temperature 250℃. The ranges of geometric standard deviation(GSD) were 1.730-1.782 for source temperature 20℃, 1.734-1.894 for source temperature 50℃, and 1.921-2.148 for source temperature 70℃. The lowest GSD was 1.730 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.148 in source temperature 70℃ and inlet temperature 250℃. Lead aerosol generated in this study was polydisperse. The ranges of mass median diameter(MMD) were 1.856-2.133μm for source temperature 20℃, 1.877-2.894μm for source temperature 50℃, and 3.120-6.109μm for source temperature 70℃. The smallest MMD was 1.856μm in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 6.109μm in source temperature 70℃ and inlet temperature 250℃. Slight increases for GMD, GSD, and MMD values were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but inlet temperature 20℃ and 50℃ for source temperature 70℃ were conformed EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but none for source temperature 70℃.

나노 사이즈 입자가 포함된 양극 활물질 함량에 따른 차량용 AGM 연축전지 성능 특성 (Performance characteristics of AGM lead acid battery with the content of positive plate incorporating nano-size additive material)

  • 임태섭;김성준;김상동;양승철;정연길
    • 한국결정성장학회지
    • /
    • 제30권4호
    • /
    • pp.123-130
    • /
    • 2020
  • AGM 연축전지(Absorbent Glass Mat Lead-Acid Battery)의 수명 특성을 결정짓는 양극 활물질(Active Material)의 주요 구성 결정인 4BS(Tetrabasic lead Sulfate)의 입자 크기를 제어하기 위해 4BS Nano Seed(NS)를 적용 중에 있다. 4BS NS 적용 시, 나노 입자 특성상 분산 안정성이 저하되어 제 기능을 다하지 못한다. 이를 개선하기 위해 기존 첨가제인 광명단(Red Lead)에 나노 입자의 4BS seed가 포함된 Incorporated Nano Seed(INS)를 함량별로 첨가하여 양극판 분석과 제품 성능을 평가하였다. INS 함량이 증가할수록 4BS 입자 크기는 작아지면서 균일해지는 특성을 확인할 수 있었으며, 반응 비표면적 증가에 따른 고율 방전 특성도 향상되는 것을 알 수 있었다. 극판 제조 공정에서의 개별 극판에 대한 입도 분포의 편차를 확인하기 위해, AGM 연축전지 200 대 대한 내부 저항 및 전압 검사를 진행하였으며 제품 제조 공정 품질 편차가 감소하는 것을 확인하였다.

Kinetic and Equilibrium Study of Lead (II) Removal by Functionalized Multiwalled Carbon Nanotubes with Isatin Derivative from Aqueous Solutions

  • Tahermansouri, Hasan;Beheshti, Marzieh
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3391-3398
    • /
    • 2013
  • The carboxylated multiwall carbon nanotubes (MWCNT-COOH) and functionalized with isatin derivative (MWCNT-isatin) have been used as efficient adsorbents for the removal of lead (Pb) from aqueous solutions. The influence of variables including pH, concentration of the lead, amount of adsorbents and contact time was investigated by the batch method. The adsorption of the lead ions from aqueous solution by modified MWCNTs was studied kinetically using different kinetic models. The kinetic data were fitted with pseudo-first-order, pseudo-second-order, and intra-particle diffusion models. The sorption process with MWCNT-COOH and MWCNT-isatin was well described by pseudo-second-order and pseudo-first-order kinetics, respectively which it was agreed well with the experimental data. Also, it involved the particle-diffusion mechanism. The values of regression coefficient of various adsorption isotherm models like Langmuir, Freundlich and Tempkin to obtain the characteristic parameters of each model have been carried out. The Langmuir isotherm was found to best represent the measured sorption data for both adsorbent.

크롬산납 무기안료 입자 제어 및 안정성에 관한 연구 (Studies on Particle Size Control and Stability of Lead Chromate Pigment Particles)

  • 박찬규;정대윤;장상목;이상록
    • 공업화학
    • /
    • 제19권3호
    • /
    • pp.264-269
    • /
    • 2008
  • 크롬산납안료입자의 합성과정에서 반응조건의 변화에 따른 입자의 성장특성, 첨가제 첨가에 의한 영향, 그리고 마이크로캡슐화에 관하여 조사하였다. 크롬산납 무기안료의 합성과정에서 생성용액의 pH가 낮을수록, 반응물질의 초기농도가 묽을수록 입자크기가 작은 균일한 분산입자를 얻을 수 있었다. 교반속도가 큰 경우에서 평균입자크기의 감소 및 증가에 대한 변화폭이 크게 나타남을 알 수 있었다. 합성된 크롬산납 안료입자의 숙성과정에 황산알루미늄을 첨가하여 표면처리 함으로써 입자크기의 제어가 가능하였고, 입자의 입도분포 상태를 최적 분산 상태로 유지하는 효과가 있음을 알 수 있었다. 안료입자의 마이크로캡슐화가 진행되는 용액의 pH 범위를 9~10, 반응온도를 $90^{\circ}C$ 이상으로 유지하고 마이크로캡슐화 후 충분한 건조를 통해 입자의 수분함량을 0.5% 이하로 유지할 때 최적의 마이크로캡슐화가 됨을 알 수 있었다.

마우스 골수 소핵 시험에 의한 디젤분진, $HgCl_2$$Pb(Ac)_2$의 유전독성효과 (Genotoxic Effects of Diesel Emission Particle Extract, $HgCl_2$ and $Pb(Ac)_2$ by the Mouse Bone Marrow Micronucleus Test)

  • 허문영;최성규;유기선;손동헌
    • 한국대기환경학회지
    • /
    • 제5권1호
    • /
    • pp.62-67
    • /
    • 1989
  • The clastogenic effects of the diesel emission particle extract (DEPE), mercuric chloride and lead acetate were examined by the mouse bone marrow micronucleus test. DEPE had a potent clastogenic effect by intraperitoneal injection with dose-response between 100 and 300mg/kg b.w.. Mercuric chloride and lead acetate also gave a clastogenic effects but mercuric chloride only had a dose-response between 1 and 3mg/kg b.w.. When DEPE was administrated with mercuric chloride or lead acetate, the frequency of micronucleated cells was slight but not significant increase in comparision to a single treatment with DEPE alone.

  • PDF