• Title/Summary/Keyword: lead particle

Search Result 260, Processing Time 0.034 seconds

Estimation of Occupational Health Standard by Relationship between Airborne Lead Concentration by Particle Size and Lead in Blood (공기중 납입자의 크기 특성과 혈액중 납농도와의 관계에 의한 허용농도 측정)

  • Park, Dong-Wook;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.265-271
    • /
    • 1996
  • This study was conducted to investigate distribution of lead particles by operation of industry, to evaluate the effect of particle size on the absorption to workers, and to recommend the Occupational Health Standard for lead. Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Average blood lead level of workers was $85.1{\mu}g/dl$ in secondary smelting manufacturing, $51.3{\mu}g/dl$ in the battery manufacturing, and below $40{\mu}g/dl$ in the litharge and radiator manufacturing industry. Blood lead levels of workers by industry were significantly different(p<0.05). From relationship between airborne lead concentrations by size and lead in blood, confidence limits of airborne lead concentration equivalent to $40{\mu}g/dl$ of permissible limit in blood, was $147.9-489.8{\mu}g/m^3$ as total lead and $28.8-79.4{\mu}g/m^3$ as ACGIH-RPM. It is recommended that two separate occupational health standards for lead should be established by particle size. Airborne concentration of $150{\mu}g/m^3$ as fatal lead dust and $30{\mu}g/m^3$ as respirable lead dust was recommended.

  • PDF

Single-particle Characterization of Aerosol Particles Collected Nearby a Lead Smelter in China

  • Jung, Hae-Jin;Song, Young-Chul;Liu, Xiande;Li, Yuwu;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.83-95
    • /
    • 2012
  • China has been a top producer and exporter of refined lead products in the world since the year 2000. After the phasing-out of leaded gasoline in the late 1990s, non-ferrous metallurgy and coal combustion have been identified as potential major sources of aerosol lead in China. This paper presents the single particle analytical results of ambient aerosol particles collected near a lead smelter using a scanning electron microscopy- energy dispersive x-ray spectroscopy (SEM-EDX). Aerosol particle samples were collected over a 24-hour period, starting from 8 pm on 31 May 2002, using a high volume TSP sampler. For this near source sample, 73 particles among 377 particles analyzed (accounting for 19.4%) were lead-containing particles mixed with other species (S, Cl, K, Ca, and/or C), which probably appeared to be from a nearby lead smelter. Lead-containing particles of less than $2{\mu}m$ size in the near source sample were most frequently encountered with the relative abundances of 42%. SEM-EDX analysis of individual standard particles, such as PbO, PbS, $PbSO_4$, $PbCl_2$, and $PbCO_3$, was also performed to assist in the clear identification of lead-containing aerosol particles. Lead-containing particles were frequently associated with arsenic and zinc, indicating that the smelter had emitted those species during the non-ferrous metallurgical process. The frequently encountered particles following the lead-containing particles were mineral dust particles, such as aluminosilicates (denoted as AlSi), $SiO_2$, and $CaCO_3$. Nitrate- and sulfate-containing particles were encountered frequently in $2-4{\mu}m$ size range, and existed mostly in the forms of $Ca(NO_3,SO_4)/C$, $(Mg,Ca)SO_4/C$, and $AlSi+(NO_3,SO_4)$. Particles containing metals (e.g., Fe, Cu, and As) in this near source sample had relative abundances of approximately 10%. Although the airborne particles collected near the lead smelter contained elevated levels of lead, other types of particles, such as $CaCO_3$-containing, carbonaceous, metal-containing, nitrates, sulfates, and fly-ash particles, showed the unique signatures of samples influenced by emissions from the lead smelter.

A Study on the Characteristic of Airborne Lead Particle Size by Industry (업종별 공기중 납입자의 입경별 분포특성에 관한 조사 연구)

  • Park, Dong Wook;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.160-171
    • /
    • 1995
  • The size characteristics of lead particle which is one of the important factors associated with absorption of lead were ignored in establishing lead standard. This study was conducted to investigate distribution of lead particles by operation of industry. Aerodynamic Mass Median Diameters (MMD) of airborne lead particles in the battery and litharge manufacturing industry were $14.1{\mu}m$ and $15.1{\mu}m$, respectively. There was no significant difference between those two values(p>0.05). However, the diameters in radiator manufacturing and secondary smelting industry were $1.3{\mu}m$, $4.9{\mu}m$, respectively. Those were significantly smaller than the particle sizes in other industries(p<0.05). Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Concentrations of lead particles smaller than $1{\mu}m$ defined as respirable fraction by OSHA's CPA model assumption were $72.4{\mu}g/m^3$ in the secondary smelting industry, exceeding $50{\mu}g/m^3$. The relationship of concentrations between total lead and lead of particles smaller than $1{\mu}m$ was log Y = 0.46 logX + 0.06(n=119, $r^2=0.44$, p=0.0001). Relationship of respirable lead concentrations between OSHA and ACGIH was significantly detected in the litharge and battery manufacturing industry(p=0.0001), but was not significant in the radiator(p=0.2720) and secondary smelting manufacturing industry(p=0.2394). As MMDs of lead particles generated in industry were small, difference of respirable lead concentration between OSHA and ACGIH became smaller. There was a significant difference between concentrations respirable lead defined by two organizations such as OSHA and ACGIH in the battery and litharge manufacturing industry. Average concentration of respirable lead by ACGIH definition was 43.3 % of total lead in secondary smelting and 48.9 % in radiator manufacturing industry, and lower fractions were indicated in battery and litharge manufacturing industry. Relationships of total lead with IPM, TPM, and RPM were significant respectively(p=0.0001) and lead concentrations by particle size could be estimated using this relationship. Linear regression equation between total lead concentration(X) and ACGIH-RPM concentration(Y) was log Y = 0.76 log X - 0.40($r^2=0.89$, p=0.0001).

  • PDF

Health Risk Assessment of Lead Ingestion Exposure by Particle Sizes in Crumb Rubber on Artificial Turf Considering Bioavailability

  • Kim, Sun-Duk;Yang, Ji-Yeon;Kim, Ho-Hyun;Yeo, In-Young;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.5.1-5.10
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the risk of ingestion exposure of lead by particle sizes of crumb rubber in artificial turf filling material with consideration of bioavailability. Methods: This study estimated the ingestion exposure by particle sizes (more than 250 um or less than 250 um) focusing on recyclable ethylene propylene diene monomer crumb rubber being used as artificial turf filling. Analysis on crumb rubber was conducted using body ingestion exposure estimate method in which total content test method, acid extraction method and digestion extraction method are reflected. Bioavailability which is a calibrating factor was reflected in ingestion exposure estimate method and applied in exposure assessment and risk assessment. Two methods using acid extraction and digestion extraction concentration were compared and evaluated. Results: As a result of the ingestion exposure of crumb rubber material, the average lead exposure amount to the digestion extraction result among crumb rubber was calculated to be $1.56{\times}10^{-4}$ mg/kg-day for low grade elementary school students and $4.87{\times}10^{-5}$ mg/kg-day for middle and high school students in 250 um or less particle size, and that to the acid extraction result was higher than the digestion extraction result. Results of digestion extraction and acid extraction showed that the hazard quotient was estimated by about over 2 times more in particle size of lower than 250 um than in higher than 250 um. There was a case of an elementary school student in which the hazard quotient exceeded 0.1. Conclusions: Results of this study confirm that the exposure of lead ingestion and risk level increases as the particle size of crumb rubber gets smaller.

양이온 물질로 오염된 지하수 정화를 위한 반응벽체 개발 : 제올라이트의 적용성 평가

  • 이승학;이재원;김시현;박준범;박상권
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.23-26
    • /
    • 2001
  • Batch test and column test were performed to develop the design factors for PRBs against the contaminated groundwater by ammonium and lead. Clinoptilolite, one of the natural zeolites having excellent cation exchange capacity(CEC), was chosen as the reactive material through the ion-exchange mechanism. In the batch test, the reactivity of Clinoptilolite to ammonium and lead was examined with varying the particle size of Clinoptilolite. The nit weight of Clinoptilolite showed removal efficiencies of 65 % against the ammonium and 98% against lead. The effect of particle size of Clinoptilolite was not noticeable. In the column test, the permeability was examined using flexible-wall permeameters with varying the particle size of Clinoptilolite. When the washed Clinoptilolite having the diameter of 0.42-0.85 nm was mixed with Jumunjin sands in 20:80 ratio (w/w), the highest permeability of 2$\times$10$^{-3}$ -7 x 10$^{-4}$ cm/s was achieved. The reactivity and the strength property of the mixed material were investigated using fixed wall column having 8 sampling ports on the wall and the direct shear test, respectively. Clinoptilolite was found to be a suitable material for PRBs against the contaminated groundwater with ammonium and/or heavy metals.

  • PDF

Particle Size Analysis of Lead Aerosol with the use of 2730ppm Lead Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구를 위한 2730ppm 납 네뷸라이징 용액에서 발생된 에어로졸의 입경분석)

  • Jeung Jae Yeal;Kang Sung Ho;Kim Sam Tae;Lee Eun Kyoung;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.518-524
    • /
    • 2003
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit was made for lead inhalation toxicology study and 2730ppm lead nebulizing solution was used to generate lead aerosol. After modification of source and inlet temperatures, the results of particle size analysis for lead aerosol were as following. The highest particle counting for source temperature 20℃ was 39933.66 in inlet temperature 100℃ and particle diameter 0.75tLm. The highest particle counting for source temperature 50℃ was 39992.71 in inlet temperature 250℃ and particle diameter 0.75μm. The highest particle counting for source temperature 70℃ was 37569.55 in inlet temperature 50℃ and particle diameter 0.75μm. The ranges of geometric mean diameter(GMD) were 0.754-0.784μm for source temperature 2℃, 0.758-0.852μm for source temperature 50℃, and 0.869-1.060μm for source temperature 70℃. The smallest GMD was 0.754μm in source temperature 20℃ and inlet temperature 20℃, and the largest GMD was 1.060μm in source temperature 70℃ and inlet temperature 250℃. The ranges of geometric standard deviation(GSD) were 1.730-1.782 for source temperature 20℃, 1.734-1.894 for source temperature 50℃, and 1.921-2.148 for source temperature 70℃. The lowest GSD was 1.730 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.148 in source temperature 70℃ and inlet temperature 250℃. Lead aerosol generated in this study was polydisperse. The ranges of mass median diameter(MMD) were 1.856-2.133μm for source temperature 20℃, 1.877-2.894μm for source temperature 50℃, and 3.120-6.109μm for source temperature 70℃. The smallest MMD was 1.856μm in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 6.109μm in source temperature 70℃ and inlet temperature 250℃. Slight increases for GMD, GSD, and MMD values were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but inlet temperature 20℃ and 50℃ for source temperature 70℃ were conformed EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but none for source temperature 70℃.

Performance characteristics of AGM lead acid battery with the content of positive plate incorporating nano-size additive material (나노 사이즈 입자가 포함된 양극 활물질 함량에 따른 차량용 AGM 연축전지 성능 특성)

  • Lim, Tae Seop;Kim, Sung Jun;Kim, Sang Dong;Yang, Seung Cheol;Jung, Yeon Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Nano seed incorporated in micro-sized 4BS (Tetrabasic lead Sulfate) seed was applied to the positive electrode active material and compared with Nano 4BS seed (NS). The dispersion of NS decreased due to the aggregation phenomenon, while the nano seed incorporated in micro-sized 4BS seed (INS) could confirm excellent dispersion. As the content of INS increased, the particle size of the active material became small and constant, which was confirmed through SEM and particle size analysis. The specific surface area for the reaction was increased and the high-rate discharge and lifetime characteristics were improved. In order to confirm the variation in particle size distribution in the plate manufacturing process, internal resistance and voltage were measured for 200 AGM lead-acid batteries, and it was confirmed that batteries quality variation decreased.

Kinetic and Equilibrium Study of Lead (II) Removal by Functionalized Multiwalled Carbon Nanotubes with Isatin Derivative from Aqueous Solutions

  • Tahermansouri, Hasan;Beheshti, Marzieh
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3391-3398
    • /
    • 2013
  • The carboxylated multiwall carbon nanotubes (MWCNT-COOH) and functionalized with isatin derivative (MWCNT-isatin) have been used as efficient adsorbents for the removal of lead (Pb) from aqueous solutions. The influence of variables including pH, concentration of the lead, amount of adsorbents and contact time was investigated by the batch method. The adsorption of the lead ions from aqueous solution by modified MWCNTs was studied kinetically using different kinetic models. The kinetic data were fitted with pseudo-first-order, pseudo-second-order, and intra-particle diffusion models. The sorption process with MWCNT-COOH and MWCNT-isatin was well described by pseudo-second-order and pseudo-first-order kinetics, respectively which it was agreed well with the experimental data. Also, it involved the particle-diffusion mechanism. The values of regression coefficient of various adsorption isotherm models like Langmuir, Freundlich and Tempkin to obtain the characteristic parameters of each model have been carried out. The Langmuir isotherm was found to best represent the measured sorption data for both adsorbent.

Studies on Particle Size Control and Stability of Lead Chromate Pigment Particles (크롬산납 무기안료 입자 제어 및 안정성에 관한 연구)

  • Park, Chan Kyu;Jung, Dae Yoon;Chang, Sang Mok;Lee, Sang Rok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.3
    • /
    • pp.264-269
    • /
    • 2008
  • For the synthesis of lead chromate pigments, we investigated the characteristics of particle growth with reacting conditions in the synthetic process, the effect of additives, and its micro-capsulation. The more tiny and uniform dispersion particles could be obtained at a lower pH and diluter intial concentration. The variation range of average pigment size was increased with the agitating speed. The pigment size could be controlled by adding aluminum sulfate as an additive, which maintained the optimum particle dispersion. It was found that the optimum micro-capsulation conditions were pH 9~10 and above $90^{\circ}C$ during the micro-capsulation of lead chromate pigment, and below 0.5% humidity after micro-capsulation.

Genotoxic Effects of Diesel Emission Particle Extract, $HgCl_2$ and $Pb(Ac)_2$ by the Mouse Bone Marrow Micronucleus Test (마우스 골수 소핵 시험에 의한 디젤분진, $HgCl_2$$Pb(Ac)_2$의 유전독성효과)

  • 허문영;최성규;유기선;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.62-67
    • /
    • 1989
  • The clastogenic effects of the diesel emission particle extract (DEPE), mercuric chloride and lead acetate were examined by the mouse bone marrow micronucleus test. DEPE had a potent clastogenic effect by intraperitoneal injection with dose-response between 100 and 300mg/kg b.w.. Mercuric chloride and lead acetate also gave a clastogenic effects but mercuric chloride only had a dose-response between 1 and 3mg/kg b.w.. When DEPE was administrated with mercuric chloride or lead acetate, the frequency of micronucleated cells was slight but not significant increase in comparision to a single treatment with DEPE alone.

  • PDF