• 제목/요약/키워드: lead measurement

검색결과 705건 처리시간 0.027초

The Application of Machine Vision to IC Surface Inspection

  • Chung, Yi-Chan;Tsai, Chih-Hung;Lin, Yu-Tang
    • International Journal of Quality Innovation
    • /
    • 제4권2호
    • /
    • pp.50-64
    • /
    • 2003
  • During IC inspection, which includes the two parts of Mark and Lead, the deviation of IC on the tape occurring in high speed movements usually generates light reflection effect, which in turn causes errors in IC recognition as measured by machine vision system. This research filters the light reflection effect by developing standard components, identifies the correct position of IC Lead, hence fixes the measurement errors or non-measurability caused by light reflection, avoids the resulting discontinued operation of measuring system, and improves the productivity.

Phase Measuring Profilometry를 이용한 반도체 칩의 Lead 높이 측정 방법 (A 3D Measurement System for the Leads of Semiconductor Chips Using Phase Measuring Profilometry)

  • 김영두;조태훈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 추계학술발표대회
    • /
    • pp.223-226
    • /
    • 2011
  • 반도체 공정에서 부품의 결함을 찾는 것은 완제품의 품질 개선을 위해 중요하다. 현재까지 많은 비전 알고리즘들이 부품의 결함을 찾기 위해 적용되고 있다. 그러나 이런 알고리즘 대부분은 2D 방식의 검사 방식에 머물고 있다. 그러나 이런 2D방식의 검사 방법은 반도체 칩의 Lead나 Pad 그리고 Solder Joint와 같이 3D 정보에 의해 불량 유무를 판결해야 하는 곳에 적용하기 어렵다. 이에 본 논문에서는 PMP(Phase Measuring Profilometry)방법에 의해 반도체 칩의 Lead부분을 검사하기 위한 시스템 구성과 방법을 제안한다.

고탄성 고분해능을 갖는 응착력 측정장치의 개발 (Development of Adhesion Force Measurement Apparatus with High Stiffness and High Resolution)

  • 김규성;윤준호
    • 한국정밀공학회지
    • /
    • 제24권3호
    • /
    • pp.140-146
    • /
    • 2007
  • To understand adhesive phenomena, we need to get force curve between two surfaces. And it is said that high stiffness force analysis system is needed to get precise force curve and more information of the surfaces. Usually the stiffness of the force measurement system is under the order of 10N/m. The stiffer force measurement system, however, results in more information on the surface, because higher stiffness lead to the wider range of force curves, secondly because the force curve obtained through the stiffer one describes more precise relationship between relative tip-sample separation and interaction force. In this paper, considering for stiffness and resolution, the cantilever was designed and we made adhesion force measurement apparatus with high stiffness and high resolution, so we measured adhesive force between Ag-ball and wafer.

BSC의 한계 극복을 위한 시스템다이내믹스의 활용 (A Study on the Application of System Dynamics to Overcome BSC Limitations)

  • 조현웅;연승준;김상욱
    • 한국시스템다이내믹스연구
    • /
    • 제8권1호
    • /
    • pp.211-227
    • /
    • 2007
  • Like the saying "You can't manage what you can't measure," performance measurement is considered as one of the most important management activities for the organizations in either private or public sector. Performance measurement, however, has thus far relied too much on financial statements. Realizing the importance of a more scientific and comprehensive performance measurement, many organizations have adopted several different systems in order to objectively estimate their balanced performance results. The Balanced Scorecard (BSC) has become a popular means to measure performance. But the BSC has also received some criticisms. In this paper four limitations in the use of the BSC are discussed : BSCs focus on unidirectional causality, are unable to distinguish delays between actions and their impacts on performance, integrate insufficiently strategy with operational measures, and lead to internal biases. We propose a system dynamics approach with causal loop diagram(CLD) to develop a Dynamic BSC in order to overcome these limitations. The results suggest that developing a BSC with system dynamics is a promising approach to supplement existing BSC frameworks.

  • PDF

선형홀센서를 이용한 전기식 구동장치의 속도 신호 구현 (A New Velocity Measurement Method using Linear Type Hall-effect Sensor for Electro-mechanical Fin Actuator)

  • 구정회;송치영
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.70-75
    • /
    • 2010
  • The objective of this paper is to propose a new velocity measurement method for an electro-mechanical fin actuator. The model of the electro-mechanical fin actuator includes uncertainties such as unknown disturbances and parameter variations in flight condition. So, an electro-mechanical fin actuator system needs robust control algorithm which requires not only position information but also velocity information. Usually, analog tachometers have been used for velocity feedback in an electro-mechanical fin actuator. However, using these types of sensors have problems such as the cost, space, and malfunction. These problems lead to propose a new velocity measurement method using linear type Hall-effect sensor. In order to verify the proposed method, several experiments are performed using Model Following Sliding Mode Controller(MFSMC). It is shown that the MFSMC with a new velocity measurement method using linear type Hall-effect sensor can satisfy the requirements without using of velocity sensor.

공공부문의 서비스품질 측정모형 개발 (Developing the Measurement Model of Service Quality in the Public Sector)

  • 라준영;이승규
    • 산업공학
    • /
    • 제20권3호
    • /
    • pp.339-352
    • /
    • 2007
  • Beyond SERVQUAL-based service quality research, we develop a measurement model of public service quality that would provide researchers and practitioners in the public sector with a foundation for systematic investigation and implementation. Firstly, we explore the attributes of public service quality that lead to customer satisfaction by using the critical incident technique (CIT). We identified four dimensions of public service qualities. We also found that the critical attributes of service quality differ according to the types of customers. Secondly, to achieve a high degree of empirical confidence, we conduct statistical tests and analyses on the classification scheme and on the attributes of service quality that we derived from the CIT analysis. Through these analyses, we could remove the redundancy among attributes and group the attributes into new constructs, which are mutually exclusive and exhaustive; we built a more sophisticated measurement model of service quality.

ECONOMIC DESIGN OF SCREENING PORCEDURES CONSIDERING INSPECTION ERRORS

  • Kim, Young-Jin
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2006년도 추계학술대회
    • /
    • pp.365-368
    • /
    • 2006
  • The implementation of a screening procedure for removing non-conforming products has become a common practice especially in high-tech manufacturing industries. Screening procedures involve a measurement on the quality characteristic of interest since decisions regarding the conformance to specifications are usually made on the basis of the realization of measurement. A significant variability in measurement procedures may result in the misclassification of an outgoing product (that is, falsely accepting defectives or falsely rejecting conforming items), which may lead to wrong interpretation on product quality, It may thus be necessary to consider the impacts of misclassification errors due to measurement variability when designing screening procedures. Along this line, this article investigates the design of screening procedures based on the assessment of misclassification errors. The main objective is to determine the screening limits on measured values so that two types of misclassification errors may properly be compromised.

  • PDF

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

A study of On-Machine Measurement for PC-NC system

  • Yoon, Gil-Sang;Kim, Gun-Hee;Cho, Myeong-Woo;Seo, Tae-Il
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권1호
    • /
    • pp.60-68
    • /
    • 2004
  • The purpose of this paper is to establish an effective inspection system by using OMM (On-Machine Measurement) system based PC-NC. This system can reduce manufacturing lead time because a workpiece is inspected at every machining process and the manufacturing system which includes inspection faculty is able to realize on-line process on CNC machining center. The proposed OMM system is composed of a few algorithms for determination of inspection parameters. It is accomplished by determining the number of measuring points, their location, measuring path using fuzzy logic, Hammersley's method, TSP (Traveling Salesperson Problem) algorithm. The inspection feature applied to this system is based on machining feature. This method is tested by simulation and experiment that are analyzed measuring data and geometry tolerance.

정밀전압, 전류, 전력측정 다기능전력계 (Multi-function Wattmeter for Voltage, Current, and Power Measurement)

  • 박영태;유권상;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권10호
    • /
    • pp.568-572
    • /
    • 2002
  • High precision voltages, currents, and electrical power measurements in wide range of frequency can be achieved by using the thermo-elements(thermal converters). This paper describes a development wattmeter, based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 480 V, power factor 0.5 (lag, lead), 1 and frequencies from 60 Hz to 3 KHz. It is intended to be used by electric utilities, standard laboratories, testing laboratories, and applications where high measurement accuracy are attractive consideration.