• Title/Summary/Keyword: lead(II)

Search Result 524, Processing Time 0.024 seconds

Clinico-pathological studies on the experimental lead poisoning in goats II. Analysis of mineral content in tissues and pathoanatomical observations (산양의 실험적 납중독에 관한 임상병리학적 관찰 II. 조직내 무기질함량 분석 및 병리해부학적 관찰)

  • Kwon, Oh-deog;Lee, Hyun-beom
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.3
    • /
    • pp.493-505
    • /
    • 1993
  • Present experiments were undertaken in order to clarify the clinico-pathological characteristics of lead poisoning in goats. Twenty goats were divided into three experimental groups(A, B and C) and a control(D). The three experimental groups received diets contaminated artificially with 10(A group), 200(B group) and $1,000(C group){\mu}g/g$ of lead for 70 days, respectively. The control group received normal diets. Hair samples collected one or two weeks interval were examed for the lead content. On day 70. all the animals were necropsied and various organs were examined pathoanatomically. In addition, various organs were analyzed for lead, zine, copper, iron and calcium content by atomic absorption spectrophotometry. From these experiments following results were obtained ; The lead content of hair was significantly increased from the $42^{nd}$, $21^{st}$ or $14^{th}$ day in all the three groups, which showed significant correlation with lead content of liver and spleen. The lead content of various organs including kidney, liver, spleen, ileum, bone and abomasum were significantly increased in accordance with the lead contamination. The increase was most prominent in abomasal wall. The zinc and copper content of liver, brain, ileum, skin, kidney, lung or muscle were increased in B and C groups whereas the iron and calcium content showed no significant change. Pathoanatomically, degeneration or necrosis of proximal convoluted tubules of kidney, peripheral necrosis of liver, fundic gland necrosis of abomasum and cerebral edema were observed in B and C groups.

  • PDF

Application of Science for Interpreting Archaeological Materials(II) - Production and Flow of Lead Glass from Mireuksa Temple - (고고자료(考古資料)의 자연과학(自然科學) 응용(應用)(II) - 익산(益山) 미륵사지(彌勒寺址) 납유리(琉璃)의 제조(製造) 및 유통(流通) -)

  • Kang, Hyung-Tae;Kim, Seong-Bae;Huh, Woo-Young;Kim, Gyu-Ho
    • Korean Journal of Heritage: History & Science
    • /
    • v.36
    • /
    • pp.241-266
    • /
    • 2003
  • Glass pieces excavated from Mireuksa Temple dated $7^{th}$ century A.D. were characterized by chemical composition, specific gravity and melting point. Lead isotope ratios of lead glasses were also compared with those of lead ore to attribute which lead ore was delivered for making lead glass. It was known that some lead glasses found in Japan were similar with those of Mireuksa Temple as comparing the data of chemical composition and lead isotope ratios. Characteristics of lead glass from Mireuksa Temple Thirty five glass pieces of Mireuksa Temple were analyzed for five oxides and found that all was lead glass system(PbO-$SiO_2$) with the range of 70~79% for PbO and 20~28% for $SiO_2$. The concentrations of oxides such as $Al_2O_3$, $Fe_2O_3$ and CuO were below 0.4%, 0.3% and 0.9%, respectively. Principal component analysis(PCA) as a statistical method was carried out to classify glasses with the similarities of chemical concentrations. The result of PCA has shown that three groups of glasses were created according to the excavation positions and two major oxides(PbO and $SiO_2$) greatly contributed to the dispersion of glasses on principal component 1(PC1) axis and trace element oxides($Al_2O_3$ and $Fe_2O_3$) for PC2 axis. Most of lead glasses were greenish by the efficacy of iron and copper oxides and some showed yellowish-green. The gravity of lead glasses was about 4.4~5.4 and estimated melting point was near $670^{\circ}C$. Lead isotope ratios of glasses were analyzed and found quite close to a lead ore from the Bupyeong mine in Gyeonggi-do. Comparison with lead glasses found in Japan Lead glasses of Mireuksa Temple were compared with those of Japan on the basis of chemical and physical data. Chemical compositions of Japanese lead glasses dated $7^{th}{\sim}8^{th}$ century A.D. were nearly similar with those of Mireuksa Temple but lead isotope ratios of those were separated into two groups. Three distribution maps of lead ores of Korea, Japan and China with lead isotope ratios were applied for lead glasses found in Japan. The result have shown that the locations of lead glasses from Fukuoka Prefecture coincided with the region of northen part of Korea and similar with those of Mireuksa Temple and lead glasses from Nara Prefecture dated $8^{th}$ century A.D. were located in the region of Japanese lead ore. This research has demonstrated that lead glasses of Mireuksa Temple conveyed to Miyajidake site, Fukuoka Prefecture around $7^{th}$ century A.D. and glass melting pots and glass beads excavated from Nara Prefecture confirmed the first use of Japanese lead ore for production of lead glasses from the end of $7^{th}$ century A.D.

Impact of Limb Lead for Generating the Standard 12-Lead ECG: Performance Evaluation (표준 12 유도 심전도 생성을 위한 활용 리드의 영향 분석)

  • UiJong Kim;Dong-Hyuk Seo;Sang-Wook Kim
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2024.05a
    • /
    • pp.683-686
    • /
    • 2024
  • 의학계에서 심혈관 질환을 정확하게 진단하는 것이 중요해지면서 이를 진단하는 가장 대표적인 방법인 심전도 검사 또한 꾸준한 관심을 받아왔다. 이와 함께, 최근 웨어러블 기기의 발전으로 인해 병원에서 전극을 부착하지 않고 간편하게 심전도를 측정할 수 있게 되었다. 하지만, 이러한 기기들은 단일 사지 유도만을 측정할 수 있다는 한계가 명확하게 존재하여, 심혈관 질환의 정확한 진단이 어렵다. 이러한 배경 속에서, 단일 사지 유도(특히, Lead I 혹은 Lead II)를 활용해 표준 12 유도 심전도를 생성하는 연구들이 활발하게 진행되고 있다. 그러나 웨어러블 기기에서 측정이 가능한 단일 유도 중 어떠한 리드를 활용하는 것이 유리한가에 관한 연구는 매우 미흡하다. 본 논문은 두 가지의 실제 데이터셋과 세 가지의 심전도 생성 기법에 대한 실험을 통해 각기 다른 사지 유도를 활용하여 표준 12 유도 심전도를 생성하였을 때의 정확도를 비교한다. 실험 결과, Lead II 를 활용하였을 때가 다른 사지 유도를 활용하였을 때 보다 훨씬 정확한 표준 12유도 심전도를 생성할 수 있음을 보여준다.

Design of Pretreatment Process of Lead Frame Etching Wastes Using Reduction-Oxidation Method (환원-산화법을 이용한 리드프레임 에칭폐액의 정제과정 설계)

  • Lee, Seung Bum;Jeon, Gil Song;Jung, Rae Yoon;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.27 no.1
    • /
    • pp.21-25
    • /
    • 2016
  • When copper alloy is used in etching process for the production of lead frame, the high concentration of heavy metals, such as iron, nickel and zinc may be included in the etching waste. Those etching waste is classified as a specified one. Therefore a customized design was designed for the purification process of the lead frame etching waste liquid containing high concentrations of heavy metals for the production of an electroplating copper(II) oxide. Since the lead frame etching waste solution contains highly concentrated heavy metal species, an ion exchange method is difficult to remove all heavy metals. In this study, a copper(I) chloride was manufactured by using water solubility difference related to the reduction-oxidation method followed by the reunion of copper(II) chloride using sodium sulfate as an oxidant. The hydrazine was chosen as a reducing agent. The optimum added amount was 1.4 mol per 1.0 mol of copper. In the case of removal of heavy metals by using the combination of reduction-oxidation and ion exchange resin methods, 4.3 ppm of $Fe^{3+}$, 2.4 ppm of $Ni^{2+}$ and 0.78 ppm of $Zn^{2+}$ can be reused as raw materials for electroplating copper(II) oxide when repeated three times.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

A Study on the Characteristics of the Precision Blanking of Lead Frame (II): Determination of Optimal Process Condition (리드 프레임 타발공정의 전단특성에 관한 연구(II) - 최적 전단 조건의 선정)

  • 서의권;임상헌;심현보
    • Transactions of Materials Processing
    • /
    • v.11 no.2
    • /
    • pp.132-137
    • /
    • 2002
  • Using the Taguchi method, optimum process condition of lead frame blanking has been determined in the point of view of shape of blanked profile. As the main process parameters, clearance, strip holding pressure and bridge width are selected. According to the orthogonal array table, three levels of experiment have been carried out for each factor. The optimal blanking condition is analyzed with the SN ratio. It has been verified that the optimal Process condition can be determined with a combination of basic blanking experiment and experiment design method. Both the effect of each factor and gain can be judged in the quantitative manner from the analysis of SN ratio.

The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy (방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구)

  • Yang, Seung-Woo;Han, Moo-Jae;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.789-794
    • /
    • 2021
  • Brachytherapy is a treatment in which radioactive isotopes are placed inside the body to intensively irradiate the tumor with radiation. Because brachytherapy uses a radioisotope source with a high dose rate, it is very important to know the exact location and dose of the source. However, in clinical practice, it is evaluated inaccurately with the naked eye through rulers and autoradiographs. Therefore, in this study, a dosimeter that can be used for brachytherapy was developed using a lead(II) iodide (PbI2) material, and the applicability was evaluated by analyzing the reproducibility, linearity, and PID items. As a result of reproducibility evaluation, the RSD value was 1.41%, satisfying the evaluation criteria of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the evaluation criterion of 0.9990. As a result of PID evaluation, it showed only a difference of 0.06 cm compared with the theoretical value of the inverse square law of distance at the 50% dose reduction point. The dosimeter manufactured in this experiment shows results that satisfy the standard in all evaluations, so it is judged that the possibility of applying the dosimeter in the radiation brachytherapy area is sufficient.

Removal of Pb(II) from wastewater by biosorption using powdered waste sludge

  • Jang, Hana;Park, Nohback;Bae, Hyokwan
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • Lead is a highly toxic heavy metal that causes serious health problems. Nonetheless, it is increasingly being used for industrial applications and is often discharged into the environment without adequate purification. In this study, Pb(II) was removed by powdered waste sludge (PWS) based on the biosorption mechanism. Different PWSs were collected from a submerged moving media intermittent aeration reactor (SMMIAR) and modified Ludzack-Ettinger (MLE) processes. The contents of extracellular polymeric substances were similar, but the surface area of MLE-PWS (2.07 ㎡/g) was higher than that of SMMIAR-PWS (0.82 ㎡/g); this is expected to be the main parameter determining Pb(II) biosorption capacity. The Bacillaceae family was dominant in both PWSs and may serve as the major responsible bacterial group for Pb(II) biosorption. Pb(II) biosorption using PWS was evaluated for reaction time, salinity effect, and isotherm equilibrium. For all experiments, MLE-PWS showed higher removal efficiency. At a fixed initial Pb(II) concentration of 20 mg/L and a reaction time of 180 minutes, the biosorption capacities (qe) for SMMIAR- and MLE-PWSs were 2.86 and 3.07 mg/g, respectively. Pb(II) biosorption using PWS was rapid; over 80% of the maximum biosorption capacity was achieved within 10 minutes. Interestingly, MLE-PWS showed enhanced Pb(II) biosorption with salinity values of up to 30 g NaCl/L. Linear regression of the Freundlich isotherm revealed high regression coefficients (R2 > 0.968). The fundamental Pb(II) biosorption capacity, represented by the KF value, was consistently higher for MLE-PWS than SMMIAR-PWS.

Relationship between the Biological Lead Exposure Indices and Air lead Concentrations measured by Personal Air Samplers (개인용 공기포집기를 이용한 기중 연농도와 생물학적 연 폭로지표와의 관련성)

  • Lee, Haeng-Ryeol;Kim, Jung-Man;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.1 s.41
    • /
    • pp.65-73
    • /
    • 1993
  • This study was carried out to evaluate the relationship between the biological lead exposure indices and air lead concentrations measured by personal air samplers. The 72 occupationally lead exposed workers were observed and the bioiogical lead Exposure indices chosen for this study were blood lead(PbB), urine lead(PbU), zinc protoporphyrin in whole blood(ZPP), $\delta$-aminolevulinic acid in urine(ALAU), $\delta$-aminolevulinic acid dehydratase activity (ALAD), coproporphyrin in urine(CPU) and hemoglobin(Hb). The workers were divided into four groups by air lead concentrations: Group I; under $0.05mg/m^3$, Group II; $0.05-0.10mg/m^3$, Group III; $0.10-0.15mg/m^3$ and Group IV; and over $0.15mg/m^3$. For evaluation the relationship between the biological lead exposure indices and air lead concentrations was used as correlation coefficients. The results obtained were as follows: 1. In Group I, II, III and IV, the mean value of PbB were $25.45{\pm}1.84{\mu}g/dl,\;27.87{\pm}3.53{\mu}g/dl,\;31.21{\pm}1.76{\mu}g/dl\;and\;47.02{\pm}13.96{\mu}g/dl$. Between Group IV and other groups showed statistically significant difference(p<0.05). 2. There was an increasing tendency of PbB, PbU, ALAU and ZPP according to the increase the mean air lead concentration, while ALAD has decreasing tendency. CPU and Hb did not show any constant tendency. 3. Correlation coefficients between PbB, PbU, ZPP, ALAU, ALAD, CPU, Hb and air lead concentration were 0.95, 0.83, 0.89, 0.72, -0.83, 0.51 and -0.45 respectively, and regression coefficient between PbB(Y) and PbA(X) was Y=126.8746X+16.9996(p<0.01).

  • PDF

Preconcentration and Determination of Trace Copper(II) and Lead(II) in Aqueous Solutions by Adsorption on Ca-Alginate Bead (알긴산칼슘 비드 상 흡착에 의한 흔적량 구리(II)와 납(II)의 동시 농축 및 정량)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • The preconcentration and determination of trace Cu(II) and Pb(II) on calcium alginate beads in aqueous solution were studied. A calcium alginate beads were prepared by adding an alginic acid to sample solution contained Ca(II). Some following conditions were optimized: the pH of sample solution, amount of alginic acid, and stirring time for effective adsorption; the type and concentration of acid, and sonication time in an ultrasonic vibrator for the perfect de-sorption. A sample solution was prepared with Cu(II) and Pb(II) in DI water. And Ca(II) and ethanol was added into the sample solution. The pH of the final sample solution was controlled with buffer solution. The alginic acid were dispersed in the sample solution by a magnetic stirrer. This mixture was stored in room temperature for 30 min to form a calcium alginate. After the beads were filtered and washed on a membrane filter, the analytes were redissolved from the beads by an ultrasonic vibration of 10 minutes in 1.0M $HNO_3$ solution. The effect of diverse ions on the adsorption of analytes were studied. This procedure was applied for the analysis of two real samples. The recoveries in spiked samples were $90.4{\sim}104.3%$ for analytes.