• Title/Summary/Keyword: lateral-force resistance

Search Result 122, Processing Time 0.029 seconds

Resistance of Web-Separated Diagrid Nodes Subjected to Cyclic Loading (반복하중에 대한 웨브전이형 다이아그리드 노드의 구조적 특성)

  • Kim, Young Ju;Jung, In Yong;Ju, Young K.;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.257-266
    • /
    • 2009
  • The results of the analysis of the structural behavior of diagrid nodes that were subjected to cyclic loads such as wind and earthquakes was not fully understood due to difficulties in considering the welding type. In this study, diagrid nodes were tested to determine their behavior when they are subjected to seismic or wind loads. Five specimens were designed and fabricated. The corresponding test parameters were the welding type for each point and the length of the overlap of the side stiffener and the brace web. Tensile force was applied to one diagrid brace member, and compression force was applied to the other diagrid brace member. Cyclic loading was applied until the failure. The test showed that failures are due to axial stress from axial force and the additional bending moment of the two combined axial forces that have different directions. Tensile failure was observed from the tensile force, and local buckling was observed from the compressive force at the flange of the brace member. In addition, the welding type and the length overlap affected the initial stiffness, the yielding stress, and the energy absorption of the diagrid node.

Fabrication of metal nano-wires using carbon nanotube masks

  • Yun, W.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.175-175
    • /
    • 1999
  • Circumventing problems lying in the conventional lithographic techniques, we devised a new method for the fabrication of nanometer scale metal wires inspired by the unique characteristics of carbon nanotubes (CNTs). Since carbon nanotubes could act as masks when CNT-coated thin Au/Ti layer on a SiO2 surface was physically etched by low energy argon ion bombardment 9ion milling), Au/Ti nano-wires were successfully formed just below the CNTs exactly duplicating their lateral shapes. Cross-sectional analysis by transmission electron microscopy revealed that the edge of the metal wire was very sharply developed indicating the great difference in the milling rates between the CNTs and the metal layer as well as the good directionality of the ion milling. We could easily find a few nanometer-wide Au/Ti wires among the wires of various width. After the formation of nano-wires, the CNTs could be pushed away from the metal nano-wire by atomic force microscopy, The lateral force for the removal of the CNTs are dependent upon the width and shape of the wires. Resistance of the metal nano-wires without the CNTs was also measured through the micro-contacts definted by electron beam lithography. since this CNT-based lithographic technique is, in principle, applicable to any kinds of materials, it can be very useful in exploring the fields of nano-science and technology, especially when it is combines with the CNT manipulation techniques.

  • PDF

Impact response of ultra-high performance fiber-reinforced concrete filled square double-skin steel tubular columns

  • Li, Jie;Wang, Weiqiang;Wu, Chengqing;Liu, Zhongxian;Wu, Pengtao
    • Steel and Composite Structures
    • /
    • v.42 no.3
    • /
    • pp.325-351
    • /
    • 2022
  • This paper studies the lateral impact behavior of ultra-high performance fiber-reinforced concrete (UHPFRC) filled double-skin steel tubular (UHPFRCFDST) columns. The impact force, midspan deflection, and strain histories were recorded. Based on the test results, the influences of drop height, axial load, concrete type, and steel tube wall thickness on the impact resistance of UHPFRCFDST members were analyzed. LS-DYNA software was used to establish a finite element (FE) model of UHPFRC filled steel tubular members. The failure modes and histories of impact force and midspan deflection of specimens were obtained. The simulation results were compared to the test results, which demonstrated the accuracy of the finite element analysis (FEA) model. Finally, the effects of the steel tube thickness, impact energy, type of concrete and impact indenter shape, and void ratio on the lateral impact performances of the UHPFRCFDST columns were analyzed.

Three-dimensional finite element analysis on intrusion of upper anterior teeth by three-piece base arch appliance according to alveolar bone loss (치조골 상실에 따른 three-piece base arch appliance를 이용한 상악전치부 intrusion에 대한 3차원 유한요소법적 연구)

  • Ha, Man-Hee;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.209-223
    • /
    • 2001
  • At intrusion of upper anterior teeth in patient with periodontal defect, the use of three-piece base arch appliance for pure intrusion is required. To investigate the change of the center of resistance and of the distal traction force according to alveolar bone height at intrusion of upper anterior teeth using this appliance, three-dimensional finite element models of upper six anterior teeth, periodontal ligament and alveolar bone were constructed. At intrusion of upper anterior teeth by three-piece base arch appliance, the following conclusions were drawn to the locations of the center of resistance according to the number of teeth, the change of distal traction force for pure intrusion and the correlation to the change of vertical, horizontal location of the center of resistance according to alveolar bone loss. 1. When the axial inclination and alveolar bone height were normal, the anteroposterior locations of center of resistance of upper anterior teeth according to the number of teeth contained were as follows : 1) In 2 anterior teeth group, the center of located in the mesial 1/3 area of lateral incisor bracket. 2) In 4 anterior teeth group. the center of resistance was located in the distal 2/3 of the distance between the bracket of lateral incisor and canine. 3) In 6 anterior teeth group, the center of resistance was located in the central area of first premolar bracket .4) As the number of teeth contained in anterior teeth group increased, the center of resistance shifted to the distal side. 2. When the alveolar bone height was normal, the anteroposterior position of the point of application of the intrusive force was the same position or a bit forward position of the center of resistance at application of distal traction force for pure intrusion. 3. When intrusion force and the point of application of the intrusive force were fixed, the changes of distal traction force for pure intrusion according to alveolar bon loss were as follows :1) Regardless of the alveolar bone loss, the distal traction force of 2, 4 anterior teeth groups were lower than that of 6 anterior teeth group. 2) As the alveolar bone loss increased, the distal traction forces of each teeth group were increased. 4. The correlations of the vertical, horizontal locations of the center of resistance according to maxillary anterior teeth groups and the alveolar bone height were as follows : 1) In 2 anterior teeth group, the horizontal position displacement to the vortical position displacement of the center of resistance according to the alveolar bone loss was the largest. As the number of teeth increased, the horizontal position displacement to the vertical position displacement of the center of resistance according to the alveolar bone loss showed a tendency to decrease. 2) As the alveolar bone loss increased, the horizontal position displacement to the vertical position displacement of the center of resistance regardless of the number of teeth was increased.

  • PDF

Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Diagrid System

  • Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Diagrid system has been in the spotlight for its superiority in terms of the resistance to lateral force when applied to skyscrapers. In diagrid system, most of columns can be eliminated because vertical loads (gravity loads) and horizontal loads (lateral loads) are delivered simultaneously thanks to the triangular shape of diagrid. However, lack of studies on connection shape and node connection details makes it hard to employ the system to the buildings. In this study, the structural safety of the node connections in circular steel tube diagrid system which has been considered in the Cyclone Tower in Korea (Seven stories below and fifty-one above the ground) was evaluated using the 4 full-scale specimens. The parameters are the extended length (20 mm, 40 mm & 60 mm), thickness (40 mm & 50 mm).

A Study on Dynamic Properties Estimation of On-Site Railroad Track (현장 궤도 동특성 추정에 관한 연구)

  • 이희현;남보현;박용진;이종득
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.2
    • /
    • pp.39-46
    • /
    • 2001
  • In this paper, train running test and lateral resistant force test are conducted before and after sprinkling the ballast stabilizer in order to investigate the dynamic behaviors and parameters of the railroad track. The measured results are used to confirm the effect of the stabilizer and to validate the numerical results. From this paper, it is known that the stabilizer used in this study has excellent effect on increasing the vertical rigidity and the lateral resistance, and some correction factors should be considered on masses and rigidities of the track components in order to calculate the vibration magnitude reasonably due to running train.

  • PDF

Sensitivity analysis of skull fracture

  • Vicini, Anthony;Goswami, Tarun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.1
    • /
    • pp.47-57
    • /
    • 2016
  • Results from multiple high profile experiments on the parameters influencing the impacts that cause skull fractures to the frontal, temporal, and parietal bones were gathered and analyzed. The location of the impact as a binary function of frontal or lateral strike, the velocity, the striking area of the impactor, and the force needed to cause skull fracture in each experiment were subjected to statistical analysis using the JMP statistical software pack. A novel neural network model predicting skull fracture threshold was developed with a high statistical correlation ($R^2=0.978$) and presented in this text. Despite variation within individual studies, the equation herein proposes a 3 kN greater resistance to fracture for the frontal bone when compared to the temporoparietal bones. Additionally, impacts with low velocities (<4.1 m/s) were more prone to cause fracture in the lateral regions of the skull when compared to similar velocity frontal impacts. Conversely, higher velocity impacts (>4.1 m/s) showed a greater frontal sensitivity.

Immediate Effects of Local Vibration on Ankle Plantarflexion Spasticity and Clonus of both the Gastrocnemius and Soleus in Patients with Spinal Cord Injury (국소진동이 척수손상환자의 발목족저굴곡 경직과 비복근과 가자미근의 간헐성 경련에 미치는 일시적 효과)

  • Ahn, Mun-Cheol;Song, Chang-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.1-11
    • /
    • 2016
  • PURPOSE: This study was conducted to assess the effects of local vibration on ankle plantarflexion spasticity and clonus in patients with spinal cord injury. METHODS: The subjects were 14 inpatients with complete or incomplete spinal cord injury (SCI) whose scores were higher than 1 on the Modified Ashworth Scale (MAS) and Spinal Cord Assessment Tool for Spastic Reflexes (SCATS) scale of paraplegia. A randomized single-blind cross-over design was used. Vibration treatment involved a single application of vibration for 10 min in the sitting position, and placebo treatment involved the patient remaining in the sitting position for 10 min. One day after treatment, vibration and placebo treatments were crossed over. Spasticity was measured by using the MAS, and resistance force, by using a hand-held dynamometer; clonus was gauged by using the SCATS scale and clonus burst duration. Additionally, the burst maximal frequency and voluntary ankle dorsiflexion angle of the triceps surae were measured. RESULTS: The application of vibration treatment in the sitting position significantly reduced the MAS scores and resistance force, but significantly increased the dorsiflexion angle of the ankle joint (p<0.05). Furthermore, the vibration treatment diminished the clonus burst duration and SCATS score significantly (p<0.05). Although it reduced the burst maximal frequency of the lateral gastrocnemius and medial soleus, this was significant only for the lateral gastrocnemius. The placebo treatment did not significantly affect any of the test parameters. CONCLUSION: Vibration treatment in the sitting position was effective in cases of spasticity and clonus caused by SCI.

Analytical Study on Structural Behaviors of Post-Tensioned Column-Base Connections for Steel Modular Structures (철골 모듈러 구조물의 포스트텐션 기둥-바닥 접합부 거동에 대한 해석적 연구)

  • Choi, Kyung-Suk;Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.6
    • /
    • pp.427-435
    • /
    • 2020
  • Modular structures are relatively lightweight compared to reinforced-concrete or steel structures. However, it is difficult to achieve structural integrity between the columns of unit modules in a modular structure, which causes undesirable effects on the lateral force resistance capacity against wind and earthquake loads. This is more prominent in modular structures whose overall heights are greater. Hence, a post-tensioned modular structural system is proposed herein to improve the lateral force resistance capacity of a typical modular structure. A post-tensioned column-base connection, which is the main component of the proposed modular structural system, is configured with shapes and characteristics that allow inducing self-centering behaviors. Finite element analysis was then performed to investigate the hysteretic behaviors of the post-tensioned column-base connection. The analysis results show that the hysteretic behaviors are significantly affected by the initial tension forces and beam-column connection details at the base.

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.